    A Modular One-Generation Reproduction Study as a Flexible Testing System for Regulatory Safety Assessment

    Get PDF
    The European Union’s Registration, Evaluation and Authorisation of Chemicals (REACH) legislation mandates testing and evaluation of approximately 30,000 existing substances within a short period of time, beginning with the most widely used “high production volume” (HPV) chemicals. REACH testing requirements for the roughly 3000 HPV chemicals specify three separate tests for reproductive toxicity: two developmental toxicity studies on different animal species (OECD Test Guideline 414) and a two-generation reproduction toxicity study (OECD TG 416). These studies are highly costly in both economic and animal welfare terms. OECD TG 416 is a fertility study intended to evaluate reproductive performance of animals in the P and F1-generations following repeated exposure to a test substance. It can also be used to detect adverse effects on structural and functional development. Thus, it has conventionally been preferred to the one-generation study (OECD TG 415). Recently, the Agricultural Chemical Safety Assessment (ACSA) Technical Committee of the ILSI Health and Environmental Sciences Institute (HESI) proposed that routine two-generation studies could in most cases be replaced with an “enhanced” one-generation study (Reuter et al. [1]). The flexible design proposed by HESI-ACSA allows for the addition of one or more specialised modules, if triggered (e.g. production of a second generation or the investigation of classical developmental toxicity or developmental neuro- or immunotoxicity). Significantly, however, the HESI-ACSA proposal was designed for use in the safety assessment of pesticidal, as opposed to industrial, chemicals. Thus for the purposes of REACH, a streamlined one-generation study that also examines structural development would be the most efficient means of addressing current information requirements for HPV chemicals. This study represents a flexible testing system that can be modified to meet regulatory needs in a variety of sectors

    Pluripotent stem cell assays: Modalities and applications for predictive developmental toxicity

    Get PDF
    This manuscript provides a review focused on embryonic stem cell-based models and their place within the landscape of alternative developmental toxicity assays. Against the background of the principles of developmental toxicology, the wide diversity of alternative methods using pluripotent stem cells developed in this area over the past half century is reviewed. In order to provide an overview of available models, a systematic scoping review was conducted following a published protocol with inclusion criteria, which were applied to select the assays. Critical aspects including biological domain, readout endpoint, availability of standardized protocols, chemical domain, reproducibility and predictive power of each assay are described in detail, in order to review the applicability and limitations of the platform in general and progress moving forward to implementation. The horizon of innovative routes of promoting regulatory implementation of alternative methods is scanned, and recommendations for further work are given

    Novel chemical hazard characterisation approaches

    Get PDF
    There is a fundamental change in thinking within the regulatory community due to a better understanding of the underlying biology of adverse effects to human health and the environment. The development of alternatives to use laboratory animals has become a priority. In addition, technological progress is impacting greatly on the amount of data available and on the ways to process and analyse it. Topics, such as identification of adverse outcome pathways (AOPs) and modes of action (MoA), together with integrated assessment and testing approaches (IATAs), represent fundamental tools for hazard identification and characterisation of a chemical. Complex endpoints cannot be predicted by a single standalone non-animal test; thus, a major challenge is the complex nature of biological systems. Microphysiological systems (MPS) will enable more complex in vitro human models that better simulate the organ's biology and function by combining different cell types in a specific three-dimensional configuration that simulates functional organs. The process of validation of new approaches needs to be considered in terms of efficiency and length. Regulators might still not have enough confidence to adopt and apply these new approaches: this phase is very challenging and the activities performed by assay developers are not yet addressing the regulatory requirements needs sufficiently. The IATAs provide a framework to consistently evaluate new approach data and could assist in understanding their relevance for specific endpoints. The data need to be reproducible, understandable and statistically sound: indeed, a major issue lies in the interpretation and integration of the results based on subjective assessment, which relies on expert judgement. A well-defined mechanistic characterisation is proposed as a way forward to ensure the relevance of new cell-based test systems

    The Embryonic Stem Cell Test as Tool to Assess Structure-Dependent Teratogenicity: The Case of Valproic Acid

    Get PDF
    Teratogenicity can be predicted in vitro using the embryonic stem cell test (EST). The EST, which is based on the morphometric measurement of cardiomyocyte differentiation and cytotoxicity parameters, represents a scientifically validated method for the detection and classification of chemicals according to their teratogenic potency. Furthermore, an abbreviated protocol applying flow cytometry of intracellular marker proteins to determine differentiation into the cardiomyocyte lineage is available. Although valproic acid (VPA) is in worldwide clinical use as antiepileptic drug, it exhibits two severe side effects, i.e., teratogenicity and hepatotoxicity. These limitations have led to extensive research into derivatives of VPA. Here we chose VPA as model compound to test the applicability domain and to further evaluate the reliability of the EST. To this end, we study six closely related congeners of VPA and demonstrate that both the standard and the molecular flow cytometry-based EST are well suited to indicate differences in the teratogenic potency among VPA analogs that differ only in chirality or side chain length. Our data show that identical results can be obtained by using the standard EST or a shortened protocol based on flow cytometry of intracellular marker proteins. Both in vitro protocols enable to reliably determine differentiation of murine stem cells toward the cardiomyocyte lineage and to assess its chemical-mediated inhibition

    The Three Rs: The Way Forward

    Get PDF
    This is the report of the eleventh of a series of workshops organised by the European Centre for the Validation of Alternative Methods (ECVAM), which was established in 1991 by the European Commission. ECVAM\u27s main goal, as defined in 1993 by its Scientific Advisory Committee, is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine or replace the use of laboratory animals. One of the first priorities set by ECVAM was the implementation of procedures which would enable it to become well-informed about the state-of-the-art of non-animal test development and validation. and the potential for the possible incorporation of replacement alternative tests into regulatory procedures. It was decided that this would be best achieved by the organisation of ECVAM workshops on specific topics, at which small groups of invited experts would review the current status of various types of in vitro tests and their potential uses, and make recommendations about the best ways forward

    Method to optimize NVH-behaviour of a brushless electrically excited synchronous machine

    No full text
    As part of the ongoing NGC-project (Next Generation Car) related to the research of new technologies for future road vehicles at the DLR, this paper is dedicated to the substitution of an optimization method of a brushless electrically excited synchronous machine for use in electrical vehicles. In this application high torque densities and small vibrations are needed, so an optimization of torque and torque ripple is done. As optimization parameters torque ripple reduction techniques as skewing, cosine formed tooth and width of tooth are chosen. The combined multi-parameter optimization is necessary because of interactions between the optimization parameter effects. An analysis for a machine of 25 kW, used in urban electric vehicles, is done with different excitations to build up the working points. The results show a large effect of increasing skewing to decrease torque and increase ripples independent of excitation. The effects of the other techniques are smaller. The cosine form has in the example optimization a strong dependency on excitation