    A 3-D Track-Finding Processor for the CMS Level-1 Muon Trigger

    Full text link
    We report on the design and test results of a prototype processor for the CMS Level-1 trigger that performs 3-D track reconstruction and measurement from data recorded by the cathode strip chambers of the endcap muon system. The tracking algorithms are written in C++ using a class library we developed that facilitates automatic conversion to Verilog. The code is synthesized into firmware for field-programmable gate-arrays from the Xilinx Virtex-II series. A second-generation prototype has been developed and is currently under test. It performs regional track-finding in a 60 degree azimuthal sector and accepts 3 GB/s of input data synchronously with the 40 MHz beam crossing frequency. The latency of the track-finding algorithms is expected to be 250 ns, including geometrical alignment correction of incoming track segments and a final momentum assignment based on the muon trajectory in the non-uniform magnetic field in the CMS endcaps.Comment: 7 pages, 5 figures, proceedings for the conference on Computing in High Energy and Nuclear Physics, March 24-28 2003, La Jolla, Californi

    The CMS Modular Track Finder boards, MTF6 and MTF7

    Get PDF
    To accommodate the increase in energy and luminosity of the upgraded LHC, the CMS Endcap Muon Level 1 Trigger system has to be significantly modified. To provide the best track reconstruction, the Trigger system must now import all available trigger primitives generated by Cathode Strip Chambers and by other regional subsystems, such as Resistive Plate Chambers. In addition to massive input bandwidth, this also requires a significant increase in logic and memory resources. To satisfy these requirements, a new Sector Processor unit for muon track finding is being designed. This unit follows the micro-TCA standard recently adopted by CMS. It consists of three modules. The Core Logic module houses the large FPGA that contains the processing logic and multi-gigabit serial links for data exchange. The Optical module contains optical receivers and transmitters; it communicates with the Core Logic module via a custom backplane section. The Look-Up Table module contains a large amount of low-latency memory that is used to assign the final transverse momentum of the muon candidate tracks. The name of the unit — Modular Track Finder — reflects the modular approach used in the design. Presented here are the details of the hardware design of the prototype unit based on Xilinx's Virtex-6 FPGA family, MTF6, as well as results of the conducted tests. Also presented are plans for the pre-production prototype based on the Virtex-7 FPGA family, MTF7

    TAXON version 1.1: A simple way to generate uniform and fractionally weighted three-item matrices from various kinds of biological data

    Get PDF
    An open-access program allowing three-item statement matrices to be generated from data such as molecular sequences does not exist so far. The recently developed LisBeth package (ver. 1.0) allows representing hypotheses of homology among taxa or areas directly as rooted trees or as hierarchies; however, this is not a standard matrix-based platform. Here we present "TAXON version 1.1" (TAXON), a program designed for building three-item statement-matrices from binary, additive (ordered) and non-additive (unordered) multistate characters, with both fractional and uniform weighting of the resulted statements.Comment: 4 pages, 1 figure, 1 Supplement, 3 Supplemental example

    Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment

    Get PDF
    The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector

    Overview of large area triple-GEM detectors for the CMS forward muon upgrade

    Get PDF
    In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848

    Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector

    Get PDF
    In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown. © CERN 2016

    Charged particle detection performance of Gas Electron Multiplier (GEM) detectors for the upgrade of CMS endcap muon system at the CERN LHC

    Get PDF
    The Compact Muon Solenoid (CMS) detector is one of the two general-purpose detectors at the CERN LHC. LHC will provide exceptional high instantaneous and integrated luminosity after second long shutdown. The forward region |η| ≥ 1:5 of CMS detector will face extremely high particle rates in tens of kHz/cm2 and hence it will affect the momentum resolution, efficiency and longevity of the muon detectors. Here, η is pseudorapidity defined as η = -ln(tan(θ/2)), where θ is the polar angle measured from z-axis. To overcome these issues the CMSGEM collaboration has proposed to install new large size rate capable Triple Gas Electron Multiplier (GEM) detectors in the forward region of CMS muon system. The first set of Triple GEM detectors will be installed in the GE1/1 region (1:6 <; |η| <; 2.2) of the muon endcap during the long shutdown 2 (LS2) of the LHC. Towards this goal, full size CMS Triple GEM detectors have been fabricated and tested at the CERN SPS, H2 and H4 test beam facility. The GEM detectors were operated with two gas mixtures: Ar/CO2 (70/30) and Ar/CO2/CF4 (45/15/40). In 2014, good quality data was collected during test beam campaigns. In this paper, the performance of the detectors is summarized based on their tracking efficiency and time resolution

    Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Get PDF
    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC.This project is at the final stages of R&D and moving to production. A large area of several 100 m 2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector.The quality control steps will include optical inspection,cleaning and baking of all materials and parts used to build the detector,leakage current tests of the GEM foils,high voltage tests,gas leak tests of the chambers and monitoring pressures time,gain calibration to know the optimal operation region of the detector,gain uniformity tests, and studying the efficiency,noise and tracking performance of the detectors in a cosmic stand using scintillator
    • …