392 research outputs found
INTERACTIONS OF THE COMPLEMENT SYSTEM WITH ENDOTOXIC LIPOPOLYSACCHARIDE : GENERATION OF A FACTOR CHEMOTACTIC FOR POLYMORPHONUCLEAR LEUKOCYTES
Endotoxic lipopolysaccharide has recently been shown to fix large amounts of the complement components related to the biologic activities mediated by that system. The present study sought to determine whether the generation of chemotactic factor by endotoxin in serum was dependent upon complement system activation. Preheating serum, incubating at 0°C, or incubating in the presence of EDTA, all prevented chemotactic factor generation as well as complement fixation by endotoxin. "Endotoxoids" deficient in complement-firing activity were also deficient in chemotactic factor generation. Chemotactic factor could not be generated by endotoxin in sera of mice congenitally deficient in the C'S component of complement, while chemotactic factor was generated by endotoxin in the sera of coisogenic mice with normal complement levels for that species. The chemotactic factor induced by endotoxin was heat stable and nondialyzable. Molecular sieve chromatography and sucrose density gradient ultracentrifugation demonstrated that the chemotactic factor was a relatively low molecular weight product (15,000–30,000) and as such different from previously scribed C' system-derived chemotactic factors. These experiments demonstrate that generation of chemotactic factor by endotoxin in serum is dependent upon C' system activation involving at least C'5. Furthermore, the relatively low molecular weight of this factor suggests that it might be derived from activation of a single complement component rather than from complexing of multiple complement components
Evaluation of the self-energy correction to the g-factor of S states in H-like ions
A detailed description of the numerical procedure is presented for the
evaluation of the one-loop self-energy correction to the -factor of an
electron in the and states in H-like ions to all orders in .Comment: Final version, December 30, 200
Phase Structure and Nonperturbative States in Three-Dimensional Adjoint Higgs Model
The thermodynamics of 3d adjoint Higgs model is considered. We study the
properties of the Polyakov loop correlators and the critical behavior at the
deconfinement phase transition. Our main tool is a reduction to the 2d
sine-Gordon model. The Polyakov loops appear to be connected with the soliton
operators in it. The known exact results in the sine-Gordon theory allow us to
study in detail the temperature dependence of the string tension, as well as to
get some information about a nonperturbative dynamics in the confinement phase.
We also consider the symmetry restoration at high temperature which makes it
possible to construct the phase diagram of the model completely.Comment: 15pp., Revtex; 4 figures; replaced by a version to be published in
Phys. Rev.
Multibaryons as Symmetric Multiskyrmions
We study non-adiabatic corrections to multibaryon systems within the bound
state approach to the SU(3) Skyrme model. We use approximate ansatze for the
static background fields based on rational maps which have the same symmetries
of the exact solutions. To determine the explicit form of the collective
Hamiltonians and wave functions we only make use of these symmetries. Thus, the
expressions obtained are also valid in the exact case. On the other hand, the
inertia parameters and hyperfine splitting constants we calculate do depend on
the detailed form of the ansatze and are, therefore, approximate. Using these
values we compute the low lying spectra of multibaryons with B <= 9 and
strangeness 0, -1 and -B. Finally, we show that the non-adiabatic corrections
do not affect the stability of the tetralambda and heptalambda found in a
previous work.Comment: 17 pages, RevTeX, no figure
[89Zr]Oxinate4 for long-term in vivo cell tracking by positron emission tomography
Purpose 111In (typically as [111In]oxinate3) is a gold standard
radiolabel for cell tracking in humans by scintigraphy. A long
half-life positron-emitting radiolabel to serve the same purpose
using positron emission tomography (PET) has long
been sought. We aimed to develop an 89Zr PET tracer for cell
labelling and compare it with [111In]oxinate3 single photon
emission computed tomography (SPECT).
Methods [89Zr]Oxinate4 was synthesised and its uptake and
efflux were measured in vitro in three cell lines and in human
leukocytes. The in vivo biodistribution of eGFP-5T33 murine
myeloma cells labelled using [89Zr]oxinate4 or [111In]oxinate3
was monitored for up to 14 days. 89Zr retention by living
radiolabelled eGFP-positive cells in vivo was monitored by
FACS sorting of liver, spleen and bone marrow cells followed
by gamma counting.
Results Zr labelling was effective in all cell types with yields
comparable with 111In labelling. Retention of 89Zr in cells
in vitro after 24 h was significantly better (range 71 to
>90 %) than 111In (43–52 %). eGFP-5T33 cells in vivo
showed the same early biodistribution whether labelled with
111In or 89Zr (initial pulmonary accumulation followed by
migration to liver, spleen and bone marrow), but later translocation
of radioactivity to kidneys was much greater for 111In.
In liver, spleen and bone marrow at least 92 % of 89Zr
remained associated with eGFP-positive cells after 7 days
in vivo.
Conclusion [89Zr]Oxinate4 offers a potential solution to the
emerging need for a long half-life PET tracer for cell tracking
in vivo and deserves further evaluation of its effects on survival
and behaviour of different cell types
Recommended from our members
Recent Developments in Neutron Detection and Multiplicity Counting with Liquid Scintillator
For many years at LLNL we have been developing time-correlated neutron detection techniques and algorithms for many applications including Arms Control, Threat Detection and Nuclear Material Assaying. Many of our techniques have been developed specifically for relatively low efficiency (a few %) inherent in the man-portable systems. Historically we used thermal neutron detectors (mainly {sup 3}He) taking advantage of the high thermal neutron interaction cross-sections but more recently we have been investigating fast neutron detection with liquid scintillators and inorganic crystals. We have discovered considerable detection advantages with fast neutron detection as the inherent nano-second production time-scales of fission and neutron induced fission are preserved instead of being lost in neutron thermalization required for thermal neutron detectors. We are now applying fast neutron technology (new fast and portable digital electronics as well as new faster and less hazardous scintillator formulations) to the safeguards regime and faster detector response times and neutron momentum sensitivity show promise in measuring, differentiating and assaying samples that have very high count rates as well as mixed fission sources (e.g. Cm and Pu). We report on measured results with our existing liquid scintillator array and progress on design of nuclear material assaying system that incorporates fast neutron detection
Core components for effective infection prevention and control programmes: new WHO evidence-based recommendations
Abstract
Health care-associated infections (HAI) are a major public health problem with a significant impact on morbidity, mortality and quality of life. They represent also an important economic burden to health systems worldwide. However, a large proportion of HAI are preventable through effective infection prevention and control (IPC) measures. Improvements in IPC at the national and facility level are critical for the successful containment of antimicrobial resistance and the prevention of HAI, including outbreaks of highly transmissible diseases through high quality care within the context of universal health coverage. Given the limited availability of IPC evidence-based guidance and standards, the World Health Organization (WHO) decided to prioritize the development of global recommendations on the core components of effective IPC programmes both at the national and acute health care facility level, based on systematic literature reviews and expert consensus. The aim of the guideline development process was to identify the evidence and evaluate its quality, consider patient values and preferences, resource implications, and the feasibility and acceptability of the recommendations. As a result, 11 recommendations and three good practice statements are presented here, including a summary of the supporting evidence, and form the substance of a new WHO IPC guideline
Combined Boyden-Flow Cytometry Assay Improves Quantification and Provides Phenotypification of Leukocyte Chemotaxis
Chemotaxis has been studied by classical methods that measure chemotactic and random motility responses in vitro, but these methods do not evaluate the total number and phenotype of migrating leukocytes simultaneously. Our objective was to develop and validate a novel assay, combined Boyden-flow cytometry chemotaxis assay (CBFCA), for simultaneous quantification and phenotypification of migrating leukocytes. CBFCA exhibited several important advantages in comparison to the classic Boyden chemotaxis assay (CBCA): 1) improved precision (intra-assay coefficients of variation (CVs): CBFCA-4.7 and 4.8% vs. CBCA-30.1 and 17.3%; inter-observer CVs: CBFCA-3.6% vs. CBCA 30.1%); 2) increased recovery of cells, which increased assay to provide increased sensitivity; 3) high specificity for determining the phenotype of migrating/attracted leukocytes; and 4) reduced performance time (CBFCA 120 min vs. CBCA 265 min). Other advantages of CBFCA are: 5) robustness, 6) linearity, 7) eliminated requirement for albumin and, importantly, 8) enabled recovery of migrating leukocytes for subsequent studies. This latter feature is of great benefit in the study of migrating leukocyte subsets. We conclude that the CBFCA is a novel and improved technique for experiments focused on understanding leukocyte trafficking during the inflammatory response
Recommended from our members
Gamma Ray Multiplicity of 252Cf Spontaneous Fission using LiBerACE
We are studying the gamma ray and neutron multiplicity of various fission processes, beginning with the spontaneous fission of {sup 252}Cf, for a variety of basic and applied science purposes. The Livermore-Berkeley Array for Collaborative Experiments (LiBerACE) consists of six high-purity germanium Clover detectors (HPGe) each enclosed by an array of 16 bismuth-germanate (BGO) detectors. These detectors were arranged in a cubic pattern around a 1 {micro}Ci {sup 252}Cf source to attempt to cover as much solid angle of gamma ray emission as possible with a high level of segmentation. The single-gamma detector response function is determined at several energies by tagging in a HPGe detector on the photopeak of one of two gamma rays in two-gamma ray calibration sources and observing the multiplicity of the remainder of the array. Summing these single-gamma responses in groups yields the response function of the array to higher multiplicity events, which are convolved with multiplicity distributions from theoretical models and compared to the measured results to test the models validity
- …