262 research outputs found

    Entropy: From Black Holes to Ordinary Systems

    Full text link
    Several results of black holes thermodynamics can be considered as firmly founded and formulated in a very general manner. From this starting point we analyse in which way these results may give us the opportunity to gain a better understanding in the thermodynamics of ordinary systems for which a pre-relativistic description is sufficient. First, we investigated the possibility to introduce an alternative definition of the entropy basically related to a local definition of the order in a spacetime model rather than a counting of microstates. We show that such an alternative approach exists and leads to the traditional results provided an equilibrium condition is assumed. This condition introduces a relation between a time interval and the reverse of the temperature. We show that such a relation extensively used in the black hole theory, mainly as a mathematical trick, has a very general and physical meaning here; in particular its derivation is not related to the existence of a canonical density matrix. Our dynamical approach of thermodynamic equilibrium allows us to establish a relation between action and entropy and we show that an identical relation exists in the case of black holes. The derivation of such a relation seems impossible in the Gibbs ensemble approach of statistical thermodynamics. From these results we suggest that the definition of entropy in terms of order in spacetime should be more general that the Boltzmann one based on a counting of microstates. Finally we point out that these results are obtained by reversing the traditional route going from the Schr\"{o}dinger equation to statistical thermodynamics

    Entropy, time irreversibility and Schroedinger equation in a primarily discrete space-time

    Full text link
    In this paper we show that the existence of a primarily discrete space-time may be a fruitful assumption from which we may develop a new approach of statistical thermodynamics in pre-relativistic conditions. The discreetness of space-time structure is determined by a condition that mimics the Heisenberg uncertainty relations and the motion in this space-time model is chosen as simple as possible. From these two assumptions we define a path-entropy that measures the number of closed paths associated with a given energy of the system preparation. This entropy has a dynamical character and depends on the time interval on which we count the paths. We show that it exists an like-equilibrium condition for which the path-entropy corresponds exactly to the usual thermodynamic entropy and, more generally, the usual statistical thermodynamics is reobtained. This result derived without using the Gibbs ensemble method shows that the standard thermodynamics is consistent with a motion that is time-irreversible at a microscopic level. From this change of paradigm it becomes easy to derive a H−theoremH-theorem. A comparison with the traditional Boltzmann approach is presented. We also show how our approach can be implemented in order to describe reversible processes. By considering a process defined simultaneously by initial and final conditions a well defined stochastic process is introduced and we are able to derive a Schroedinger equation, an example of time reversible equation.Comment: latex versio

    The Time-Course of Changes in Muscle Mass, Architecture and Power During 6 Weeks of Plyometric Training

    Get PDF
    Purpose: To investigate the time-course of changes in knee-extensors muscle mass, architecture and function in response to plyometric training (PLT) performed on a novel training device, the Tramp-Trainer. This machine consists in a trampoline connected to an inclined sledge which allows the performance of repeated jumps while the subject is sitting on a chair. Methods: Eight healthy males (173.6 \ub1 4.7 cm, 69.7 \ub1 13.5 kg, 25.3 \ub1 4.6 years) underwent 6 weeks of bilateral PLT on the tramp-trainer machine. Training was performed three times per week (between 120 and 150 bounces per session). Knee-extensor maximum voluntary torque (MVT) and power, quadriceps femoris (QF) volume (VOL), cross-sectional area from the 20% to the 60% of femur length and CSAmean, together with vastus lateralis (VL) architecture (fascicle length, Lf, and pennation angle, PA) were assessed after 2, 4, and 6 weeks of PLT. Results: All results are presented as changes versus baseline values. MVT increased by 17.8% (week 2, p < 0.001) and 22.2% (week 4, p < 0.01), respectively, and declined to 13.3% (p < 0.05) at week 6 of PLT. Power increased by 18.2% (week 4, p < 0.05) and 19.7% (week 6, p < 0.05). QF VOL increased by 4.7% (week 4, p < 0.05) and 5.8% (week 6, p < 0.01); VL VOL increased by 5.2%, (p < 0.05), 8.2%, (p < 0.01), and 9.6% (p < 0.05) at weeks 2, 4, and 6, respectively. An increase in Lf was detected already at wk 2 (2.2%, p < 0.05), with further increase at 4 and 6 weeks of PLT (4 and 4.4%, respectively, p < 0.01). PA increased by 5.8% (p < 0.05) at week 6. Significant positive correlations were found between CSAmean and Power (R2 = 0.46, p < 0.001) and between QF VOL and Power (R2 = 0.44, p < 0.024). Conclusions: PLT induced rapid increases in muscle volume, fascicle length, pennation angle, torque and power in healthy younger adults. Notably, changes in VL VOL and Lf were detectable already after 2 weeks, followed by increases in knee extensors VOL and power from week 4 of PLT. Since the increase in CSAmean and QF VOL cannot fully explain the increment in muscle power, it is likely that other factors (such as adaptations in neural drive or tendon mechanical properties) may have contributed to such fucntional changes

    Review on Augmented Reality in Oral and Cranio-Maxillofacial Surgery: Toward 'Surgery-Specific' Head-Up Displays

    Get PDF
    In recent years, there has been an increasing interest towards the augmented reality as applied to the surgical field. We conducted a systematic review of literature classifying the augmented reality applications in oral and cranio-maxillofacial surgery (OCMS) in order to pave the way to future solutions that may ease the adoption of AR guidance in surgical practice. Publications containing the terms 'augmented reality' AND 'maxillofacial surgery', and the terms 'augmented reality' AND 'oral surgery' were searched in the PubMed database. Through the selected studies, we performed a preliminary breakdown according to general aspects, such as surgical subspecialty, year of publication and country of research; then, a more specific breakdown was provided according to technical features of AR-based devices, such as virtual data source, visualization processing mode, tracking mode, registration technique and AR display type. The systematic search identified 30 eligible publications. Most studies (14) were in orthognatic surgery, the minority (2) concerned traumatology, while 6 studies were in oncology and 8 in general OCMS. In 8 of 30 studies the AR systems were based on a head-mounted approach using smart glasses or headsets. In most of these cases (7), a video-see-through mode was implemented, while only 1 study described an optical-see-through mode. In the remaining 22 studies, the AR content was displayed on 2D displays (10), full-parallax 3D displays (6) and projectors (5). In 1 case the AR display type is not specified. AR applications are of increasing interest and adoption in oral and cranio-maxillofacial surgery, however, the quality of the AR experience represents the key requisite for a successful result. Widespread use of AR systems in the operating room may be encouraged by the availability of 'surgery-specific' head-mounted devices that should guarantee the accuracy required for surgical tasks and the optimal ergonomics

    Wearable augmented reality platform for aiding complex 3D trajectory tracing

    Get PDF
    Augmented reality (AR) Head-Mounted Displays (HMDs) are emerging as the most efficient output medium to support manual tasks performed under direct vision. Despite that, technological and human-factor limitations still hinder their routine use for aiding high-precision manual tasks in the peripersonal space. To overcome such limitations, in this work, we show the results of a user study aimed to validate qualitatively and quantitatively a recently developed AR platform specifically conceived for guiding complex 3D trajectory tracing tasks. The AR platform comprises a new-concept AR video see-through (VST) HMD and a dedicated software framework for the effective deployment of the AR application. In the experiments, the subjects were asked to perform 3D trajectory tracing tasks on 3D-printed replica of planar structures or more elaborated bony anatomies. The accuracy of the trajectories traced by the subjects was evaluated by using templates designed ad hoc to match the surface of the phantoms. The quantitative results suggest that the AR platform could be used to guide high-precision tasks: on average more than 94% of the traced trajectories stayed within an error margin lower than 1 mm. The results confirm that the proposed AR platform will boost the profitable adoption of AR HMDs to guide high precision manual tasks in the peripersonal space

    A formally exact field theory for classical systems at equilibrium

    Full text link
    We propose a formally exact statistical field theory for describing classical fluids with ingredients similar to those introduced in quantum field theory. We consider the following essential and related problems : i) how to find the correct field functional (Hamiltonian) which determines the partition function, ii) how to introduce in a field theory the equivalent of the indiscernibility of particles, iii) how to test the validity of this approach. We can use a simple Hamiltonian in which a local functional transposes, in terms of fields, the equivalent of the indiscernibility of particles. The diagrammatic expansion and the renormalization of this term is presented. This corresponds to a non standard problem in Feynman expansion and requires a careful investigation. Then a non-local term associated with an interaction pair potential is introduced in the Hamiltonian. It has been shown that there exists a mapping between this approach and the standard statistical mechanics given in terms of Mayer function expansion. We show on three properties (the chemical potential, the so-called contact theorem and the interfacial properties) that in the field theory the correlations are shifted on non usual quantities. Some perspectives of the theory are given.Comment: 20 pages, 8 figure

    Functional Magnetic Resonance in the Evaluation of Oesophageal Motility Disorders

    Get PDF
    Functional magnetic resonance imaging (fMRI) has been recently proposed for the evaluation of the esophagus. Our aim is to assess the role of fMRI as a technique to assess morphological and functional parameters of the esophagus in patients with esophageal motor disorders and in healthy controls. Subsequently, we assessed the diagnostic efficiency of fMRI in comparison to videofluoroscopic and manometric findings in the investigation of patients with esophageal motor disorders. Considering that fMRI was shown to offer valuable information on bolus transit and on the caliber of the esophagus, variations of these two parameters in the different types of esophageal motor alterations have been assessed. fMRI, compared to manometry and videofluoroscopy, showed that a deranged or absent peristalsis is significantly associated with slower transit time and with increased esophageal diameter. Although further studies are needed, fMRI represents a promising noninvasive technique for the integrated functional and morphological evaluation of esophageal motility disorders

    Clinical Management of Acinic Cell Carcinoma of the Lacrimal Gland

    Get PDF
    To report a case of acinic cell carcinoma occurred in the lacrimal gland. A 59-year-old man was admitted because of sudden blurring of vision, progressive proptosis of the left eye, and mild double vision in left and down directions of the gaze (Hess-Lancaster test). His medical history detailed controlled bilateral keratoconus and open angle glaucoma. On examination, the best corrected visual acuity decreased from 8/20 till 1/50 in one week. There was a swelling of the left upper eyelid. A hard and tender mass was palpated in the superior temporal left orbit. Ultrasound scan showed an extraconal solid mass, situated in the superior lateral corner of the orbit. Computed tomography and magnetic resonance imaging (MRI) revealed a mass of two centimeters in diameter, with round well-defined outline, within the lacrimal gland. We per-formed an enucleoresection of the mass, via a coronal approach and a lateral orbitotomy by a piezosurgical device. The lesion appeared nodular, brownish, measuring about 2 7 1.5 cm. Histopathological findings were consistent with acinic cell carcinoma with a microcystic, focally papillary-cystic growth of pattern. Follow-up MRI outcomes led to removal of the residual lacrimal gland for suspicion of recurrence. No tumor recurrences where detected at 7-year follow-up

    AEducaAR, Anatomical Education in Augmented Reality: A Pilot Experience of an Innovative Educational Tool Combining AR Technology and 3D Printing

    Get PDF
    Gross anatomy knowledge is an essential element for medical students in their education, and nowadays, cadaver-based instruction represents the main instructional tool able to provide three-dimensional (3D) and topographical comprehensions. The aim of the study was to develop and test a prototype of an innovative tool for medical education in human anatomy based on the combination of augmented reality (AR) technology and a tangible 3D printed model that can be explored and manipulated by trainees, thus favoring a three-dimensional and topographical learning approach. After development of the tool, called AEducaAR (Anatomical Education with Augmented Reality), it was tested and evaluated by 62 second-year degree medical students attending the human anatomy course at the International School of Medicine and Surgery of the University of Bologna. Students were divided into two groups: AEducaAR-based learning (“AEducaAR group”) was compared to standard learning using human anatomy atlas (“Control group”). Both groups performed an objective test and an anonymous questionnaire. In the objective test, the results showed no significant difference between the two learning methods; instead, in the questionnaire, students showed enthusiasm and interest for the new tool and highlighted its training potentiality in open-ended comments. Therefore, the presented AEducaAR tool, once implemented, may contribute to enhancing students’ motivation for learning, increasing long-term memory retention and 3D comprehension of anatomical structures. Moreover, this new tool might help medical students to approach to innovative medical devices and technologies useful in their future careers
    • 

    corecore