834 research outputs found

    From Design to Production Control Through the Integration of Engineering Data Management and Workflow Management Systems

    Full text link
    At a time when many companies are under pressure to reduce "times-to-market" the management of product information from the early stages of design through assembly to manufacture and production has become increasingly important. Similarly in the construction of high energy physics devices the collection of (often evolving) engineering data is central to the subsequent physics analysis. Traditionally in industry design engineers have employed Engineering Data Management Systems (also called Product Data Management Systems) to coordinate and control access to documented versions of product designs. However, these systems provide control only at the collaborative design level and are seldom used beyond design. Workflow management systems, on the other hand, are employed in industry to coordinate and support the more complex and repeatable work processes of the production environment. Commercial workflow products cannot support the highly dynamic activities found both in the design stages of product development and in rapidly evolving workflow definitions. The integration of Product Data Management with Workflow Management can provide support for product development from initial CAD/CAM collaborative design through to the support and optimisation of production workflow activities. This paper investigates this integration and proposes a philosophy for the support of product data throughout the full development and production lifecycle and demonstrates its usefulness in the construction of CMS detectors.Comment: 18 pages, 13 figure

    A method to localize gamma-ray bursts using POLAR

    Full text link
    The hard X-ray polarimeter POLAR aims to measure the linear polarization of the 50-500 keV photons arriving from the prompt emission of gamma-ray bursts (GRBs). The position in the sky of the detected GRBs is needed to determine their level of polarization. We present here a method by which, despite of the polarimeter incapability of taking images, GRBs can be roughly localized using POLAR alone. For this purpose scalers are attached to the output of the 25 multi-anode photomultipliers (MAPMs) that collect the light from the POLAR scintillator target. Each scaler measures how many GRB photons produce at least one energy deposition above 50 keV in the corresponding MAPM. Simulations show that the relative outputs of the 25 scalers depend on the GRB position. A database of very strong GRBs simulated at 10201 positions has been produced. When a GRB is detected, its location is calculated searching the minimum of the chi2 obtained in the comparison between the measured scaler pattern and the database. This GRB localization technique brings enough accuracy so that the error transmitted to the 100% modulation factor is kept below 10% for GRBs with fluence Ftot \geq 10^(-5) erg cm^(-2) . The POLAR localization capability will be useful for those cases where no other instruments are simultaneously observing the same field of view.Comment: 13 pages, 10 figure

    The electromagnetic calorimeter of the AMS-02 experiment

    Full text link
    The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structure, it can also provide the separation of positrons from protons, in the GeV to TeV region. A direct measurement of high energy photons with accurate energy and direction determination can also be provided.Comment: Proceedings of SF2A conference 201

    Sacral Fractures and Associated Injuries.

    Get PDF
    STUDY DESIGN: Literature review. OBJECTIVE: The aim of this review is to describe the injuries associated with sacral fractures and to analyze their impact on patient outcome. METHODS: A comprehensive narrative review of the literature was performed to identify the injuries associated with sacral fractures. RESULTS: Sacral fractures are uncommon injuries that result from high-energy trauma, and that, due to their rarity, are frequently underdiagnosed and mistreated. Only 5% of sacral fractures occur in isolation. Injuries most often associated with sacral fractures include neurologic injuries (present in up to 50% of sacral fractures), pelvic ring disruptions, hip and lumbar spine fractures, active pelvic/ abdominal bleeding and the presence of an open fracture or significant soft tissue injury. Diagnosis of pelvic ring fractures and fractures extending to the lumbar spine are key factors for the appropriate management of sacral fractures. Importantly, associated systemic (cranial, thoracic, and abdominopelvic) or musculoskeletal injuries should be promptly assessed and addressed. These associated injuries often dictate the management and eventual outcome of sacral fractures and, therefore, any treatment algorithm should take them into consideration. CONCLUSIONS: Sacral fractures are complex in nature and often associated with other often-missed injuries. This review summarizes the most relevant associated injuries in sacral fractures and discusses on their appropriate management

    The Development of a Universally Accepted Sacral Fracture Classification: A Survey of AOSpine and AOTrauma Members.

    Get PDF
    Study Design Survey study. Objective To determine the global perspective on controversial aspects of sacral fracture classifications. Methods While developing the AOSpine Sacral Injury Classification System, a survey was sent to all members of AOSpine and AOTrauma. The survey asked four yes-or-no questions to help determine the best way to handle controversial aspects of sacral fractures in future classifications. Chi-square tests were initially used to compare surgeons\u27 answers to the four key questions of the survey, and then the data was modeled through multivariable logistic regression analysis. Results A total of 474 surgeons answered all questions in the survey. Overall 86.9% of respondents felt that the proposed hierarchical nature of injuries was appropriate, and 77.8% of respondents agreed that that the risk of neurologic injury is highest in a vertical fracture through the foramen. Almost 80% of respondents felt that the separation of injuries based on the integrity of L5-S1 facet was appropriate, and 83.8% of surgeons agreed that a nondisplaced sacral U fracture is a clinically relevant entity. Conclusion This study determines the global perspective on controversial areas in the injury patterns of sacral fractures and demonstrates that the development of a comprehensive and universally accepted sacral classification is possible

    Ground state hyperfine structures of 43K and 44K measured by atomic beam magnetic resonance coupled with laser optical pumping

    No full text
    The ground state hyperfine structures of 43 K and 44K have been measured by an atomic beam magnetic resonance method in which the atoms are spin-polarized by laser optical pumping. The spectroscopic results are : Δv43( 2S1/2) = 192.648 4 (30) MHz and Δν44( 2S1/2) = - 946.718 (3) MHz. The sensitivity of our method is compared to the one achieved in classical ABMR apparatus

    An Assessment of the World's Contribution to Spine Trauma Care: A Bibliometric Analysis of Classifications and Surgical Management; An AO Spine Knowledge Forum Trauma Initiative.

    Get PDF
    STUDY DESIGN Bibliometric analysis. OBJECTIVES An analysis of the literature related to the assessment and management of spinal trauma was undertaken to allow the identification of top contributors, collaborations and research trends. METHODS A search to identify original articles published in English between 2011 and 2020 was done using specific keywords in the Web of Science database. After screening, the top 300 most cited articles were analyzed using Biblioshiny R software. RESULTS The highest number of contributions were from the Thomas Jefferson University, USA, University of Toronto and University of British Columbia, Canada. The top 3 most prolific authors were Vaccaro AR, Arabi B, and Oner FC. The USA and Canada were among the top contributing countries; Switzerland and Brazil had most multiple country co-authored articles. The most relevant journals were the European Spine Journal, Spine and Spine Journal. Three of the 5 most cited articles were about classification systems of fractures. The keyword analysis included clusters for different spinal regions, spinal cord injury, classification agreement and reliability studies, imaging related studies, surgical techniques and outcomes. CONCLUSIONS The study identified the most impactful authors and affiliations, and determined the journals where most impactful research is published in the field. Study also compared the productivity and collaborations across countries. The study highlighted the impact of development of new classification systems, and identified research trends including instrumentation, fixation and decompression techniques, epidemiology and recovery after spinal trauma

    Immunohistochemical localization of collagen types I and VI in human skin wounds

    Get PDF
    A total of 74 human skin wounds were investigated and collagen types I and VI were localized in the wound area by immunohistochemistry. Collagen type I appeared in the form of ramifying string-like structures after approximately 5–6 days, but positive reactions in the form of a spot-like staining around isolated fibroblasts also occurred in a skin wound aged 4 days. Collagen VI was detectable after a post-infliction interval of at least 3 days showing a strongly positive reacting network associated with fibroblasts in the wound area. Both collagens appeared almost constantly after a wound age of 6–7 clays and could also be found in wounds aged a few months. Therefore, although a positive reaction for collagen type I in the form of string-like and ramifying structures around wound fibroblasts indicates a wound age of at least 5–6 days, a spot-like positive staining for collagen type I cannot exclude a wound age of at least 4 days. A positive staining for collagen type VI represents a post-infliction time of 3 days or more. The almost constant appearance of these collagen types suggests that negative results in a sufficient number of specimens indicate a wound age of less than 6–7 days, but cannot completely exclude longer post-infliction intervals. Since collagen type I and VI are also found in the granulation/scar tissue of lesions with advanced wound age, the immunohistochemical analysis of these proteins provides no further information for an age determination of older skin wounds
    corecore