28 research outputs found

    Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.

    Get PDF
    PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm

    Endoleak and in-stent thrombus detection with CT angiography in a thoracic aortic aneurysm phantom at different tube energies using filtered back projection and iterative algorithms.

    Get PDF
    PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm

    Radiation exposure of adrenal vein sampling: a German Multicenter Study

    Get PDF
    Objective: Adrenal vein sampling (AVS) represents the current diagnostic standard for subtype differentiation in primary aldosteronism (PA). However, AVS has its drawbacks. It is invasive, expensive, requires an experienced interventional radiologist and comes with radiation exposure. However, exact radiation exposure of patients undergoing AVS has never been examined. Design and methods: We retrospectively analyzed radiation exposure of 656 AVS performed between 1999 and 2017 at four university hospitals. The primary outcomes were dose area product (DAP) and fluoroscopy time (FT). Consecutively the effective dose (ED) was approximately calculated. Results: Median DAP was found to be 32.5Gy*cm(2) (0.3-3181) and FT 18 min (0.3-184). The calculated ED was 6.4 mSv (0.1-636). Remarkably, values between participating centers highly varied: Median DAP ranged from 16 to 147 Gy*cm(2), FT from 16 to 27 min, and ED from 3.2 to 29 mSv. As main reason for this variation, differences regarding AVS protocols between centers could be identified, such as number of sampling locations, frames per second and the use of digital subtraction angiographies. Conclusion: This first systematic assessment of radiation exposure in AVS not only shows fairly high values for patients, but also states notable differences among the centers. Thus, we not only recommend taking into account the risk of radiation exposure, when referring patients to undergo AVS, but also to establish improved standard operating procedures to prevent unnecessary radiation exposure

    Genotype-Specific Steroid Profiles Associated With Aldosterone-Producing Adenomas

    Full text link
    Primary aldosteronism comprises 2 main subtypes: unilateral aldosterone-producing adenoma (APA) and bilateral adrenal hyperplasia. Somatic KCNJ5 mutations are found in APA at a prevalence of around 40% that drive and sustain aldosterone excess. Somatic APA mutations have been described in other genes (CACNA1D, ATP1A1, and ATP2B3) albeit at a lower frequency. Our objective was to identify genotype-specific steroid profiles in adrenal venous (AV) and peripheral venous (PV) plasma in patients with APAs. We measured the concentrations of 15 steroids in AV and PV plasma samples by liquid chromatography-tandem mass spectrometry from 79 patients with confirmed unilateral primary aldosteronism. AV sampling lateralization ratios of steroids normalized either to cortisol or to DHEA+androstenedione were also calculated. The hybrid steroid 18-oxocortisol exhibited 18- and 16-fold higher concentrations in lateralized AV and PV plasma, respectively, from APA with KCNJ5 mutations compared with all other APA combined together (P<0.001). Lateralization ratios for the KCNJ5 group were also generally higher. Strikingly, we demonstrate that a distinct steroid signature can differentiate APA genotype in AV and PV plasma. Notably, a 7-steroid fingerprint in PV plasma correctly classified 92% of the APA according to genotype. Prospective studies are necessary to translate these findings into clinical practice and determine if steroid fingerprinting could be of value to select patients with primary aldosteronism who are particularly suitable candidates for adrenal venous sampling because of a high probability of having an APA

    Mass Spectrometry-Based Adrenal and Peripheral Venous Steroid Profiling for Subtyping Primary Aldosteronism

    Full text link
    BACKGROUND Differentiating patients with primary aldosteronism caused by aldosterone-producing adenomas (APAs) from those with bilateral adrenal hyperplasia (BAH), which is essential for choice of therapeutic intervention, relies on adrenal venous sampling (AVS)-based measurements of aldosterone and cortisol. We assessed the utility of LC-MS/MS-based steroid profiling to stratify patients with primary aldosteronism. METHODS Fifteen adrenal steroids were measured by LC-MS/MS in peripheral and adrenal venous plasma from AVS studies for 216 patients with primary aldosteronism at 3 tertiary referral centers. Ninety patients were diagnosed with BAH and 126 with APAs on the basis of immunoassay-derived adrenal venous aldosterone lateralization ratios. RESULTS Among 119 patients confirmed to have APAs at follow-up, LC-MS/MS-derived lateralization ratios of aldosterone normalized to cortisol, dehydroepiandrosterone, and androstenedione were all higher (P < 0.0001) than immunoassay-derived ratios. The hybrid steroids, 18-oxocortisol and 18-hydroxycortisol, also showed lateralized secretion in 76% and 35% of patients with APAs. Adrenal venous concentrations of glucocorticoids and androgens were bilaterally higher in patients with BAH than in those with APAs. Consequently, peripheral plasma concentrations of 18-oxocortisol were 8.5-fold higher, whereas concentrations of cortisol, corticosterone, and dehydroepiandrosterone were lower in patients with APAs than in those with BAH. Correct classification of 80% of cases of APAs vs BAH was thereby possible by use of a combination of steroids in peripheral plasma. CONCLUSIONS LC-MS/MS-based steroid profiling during AVS achieves higher aldosterone lateralization ratios in patients with APAs than immunoassay. LC-MS/MS also enables multiple measures for discriminating unilateral from bilateral aldosterone excess, with potential use of peripheral plasma for subtype classification

    Dissecting Disorder Perceptions: Neighborhood Structure and the Moderating Role of Interethnic Contact and Xenophobic Attitudes

    Get PDF
    Although urban disorder has played a central role in neighborhood research, its impact may have been overstated in studies relying on the subjective perception of survey respondents only. Research on the “perception bias”—defined as the divergence between respondents’ subjective assessments and systematic observations of disorder—has revealed the ambiguous nature of disorder and opened a door to the analysis of the social construction of this environmental cognition. Using survey and observational data from 140 small neighborhoods in two German cities, we advance this research by focusing on the moderating role of residents’ interethnic contacts and attitudes. The results show that the effects of neighborhood minority concentration on the perception bias are conditional on the residents’ interethnic contacts and xenophobic attitudes. These findings highlight the subjectivity of disorder perceptions and caution against a naive understanding of Broken Windows theory
    corecore