352 research outputs found

    Avaliação dos danos de Sibinia spp. (Coleoptera: Curculionidae) em sementes de Bracatinga (Mimosa scabrella Benth.) de três procedências.

    Get PDF
    bitstream/item/101248/1/PA-1983-Iede-AvaliacaoDanos.pd

    Long-term variability of AGN at hard X-rays

    Get PDF
    Variability at all observed wavelengths is a distinctive property of AGN. Hard X-rays provide us with a view of the innermost regions of AGN, mostly unbiased by absorption along the line of sight. Swift/BAT offers the unique opportunity to follow, on time scales of days to years and with a regular sampling, the 14-195 keV emission of the largest AGN sample available up to date for this kind of investigation. We study the amplitude of the variations, and their dependence on sub-class and on energy, for a sample of 110 radio quiet and radio loud AGN selected from the BAT 58-month survey. About 80% of the AGN in the sample are found to exhibit significant variability on months to years time scales, radio loud sources being the most variable. The amplitude of the variations and their energy dependence are incompatible with variability being driven at hard X-rays by changes of the absorption column density. In general, the variations in the 14-24 and 35-100 keV bands are well correlated, suggesting a common origin of the variability across the BAT energy band. However, radio quiet AGN display on average 10% larger variations at 14-24 keV than at 35-100 keV and a softer-when-brighter behavior for most of the Seyfert galaxies with detectable spectral variability on month time scale. In addition, sources with harder spectra are found to be more variable than softer ones. These properties are generally consistent with a variable power law continuum, in flux and shape, pivoting at energies >~ 50 keV, to which a constant reflection component is superposed. When the same time scales are considered, the timing properties of AGN at hard X-rays are comparable to those at lower energies, with at least some of the differences possibly ascribable to components contributing differently in the two energy domains (e.g., reflection, absorption).Comment: 17 pages, 11 figures, accepted for publication in A&

    Contribuição à biologia larval de Hylesia sp. (Lepidoptera: Hemileucidae) em Bracatinga (Mimosa scabrella Benth.).

    Get PDF
    bitstream/item/101249/1/PA-1983-Iede-ContribuicaoBiologia.pd

    Exchange bias in GeMn nanocolumns: the role of surface oxidation

    Full text link
    We report on the exchange biasing of self-assembled ferromagnetic GeMn nanocolumns by GeMn-oxide caps. The x-ray absorption spectroscopy analysis of this surface oxide shows a multiplet fine structure that is typical of the Mn2+ valence state in MnO. A magnetization hysteresis shift |HE|~100 Oe and a coercivity enhancement of about 70 Oe have been obtained upon cooling (300-5 K) in a magnetic field as low as 0.25 T. This exchange bias is attributed to the interface coupling between the ferromagnetic nanocolumns and the antiferromagnetic MnO-like caps. The effect enhancement is achieved by depositing a MnO layer on the GeMn nanocolumns.Comment: 7 pages, 5 figure

    Spin-down rate and inferred dipole magnetic field of the soft gamma-ray repeater SGR 1627-41

    Get PDF
    Using Chandra data taken on 2008 June, we detected pulsations at 2.59439(4) s in the soft gamma-ray repeater SGR 1627-41. This is the second measurement of the source spin period and allows us to derive for the first time a long-term spin-down rate of (1.9 +/- 0.4)E-11 s/s. From this value we infer for SGR 1627-41 a characteristic age of 2.2 kyr, a spin-down luminosity of 4E+34 erg/s (one of the highest among sources of the same class), and a surface dipole magnetic field strength of 2E+14 G. These properties confirm the magnetar nature of SGR 1627-41; however, they should be considered with caution since they were derived on the basis of a period derivative measurement made using two epochs only and magnetar spin-down rates are generally highly variable. The pulse profile, double-peaked and with a pulsed fraction of (13 +/- 2)% in the 2-10 keV range, closely resembles that observed by XMM-Newton in 2008 September. Having for the first time a timing model for this SGR, we also searched for a pulsed signal in archival radio data collected with the Parkes radio telescope nine months after the previous X-ray outburst. No evidence for radio pulsations was found, down to a luminosity level 10-20 times fainter (for a 10% duty cycle and a distance of 11 kpc) than the peak luminosity shown by the known radio magnetars.Comment: 5 pages, 2 figures; accepted for publication in MNRAS Letter

    In-flight calibration of the INTEGRAL/IBIS mask

    Full text link
    Since the release of the INTEGRAL Offline Scientific Analysis (OSA) software version 9.0, the ghost busters module has been introduced in the INTEGRAL/IBIS imaging procedure, leading to an improvement of the sensitivity around bright sources up to a factor of 7. This module excludes in the deconvolution process the IBIS/ISGRI detector pixels corresponding to the projection of a bright source through mask elements affected by some defects. These defects are most likely associated with screws and glue fixing the IBIS mask to its support. Following these major improvements introduced in OSA 9, a second order correction is still required to further remove the residual noise, now at a level of 0.2-1% of the brightest source in the field of view. In order to improve our knowledge of the IBIS mask transparency, a calibration campaign has been carried out during 2010-2012. We present here the analysis of these data, together with archival observations of the Crab and Cyg X-1, that allowed us to build a composite image of the mask defects and to investigate the origin of the residual noise in the IBIS/ISGRI images. Thanks to this study, we were able to point out a simple modification of the ISGRI analysis software that allows to significantly improve the quality of the images in which bright sources are detected at the edge of the field of view. Moreover, a refinement of the area excluded by the ghost busters module is considered, and preliminary results show improvements to be further tested. Finally, this study indicates further directions to be investigated for improving the ISGRI sensitivity, such as taking into account the thickness of the screws in the mask model or studying the possible discrepancy between the modeled and actual mask element bridges.Comment: accepted for publication in the proceedings of "An INTEGRAL view of the high-energy sky (the first 10 years)" 9th INTEGRAL Workshop, October 15-19, 2012, Paris, France, in Proceedings of Science (INTEGRAL 2012), Eds. A. Goldwurm, F. Lebrun and C. Winkler, (http://pos.sissa.it/cgi-bin/reader/conf.cgi?confid=176), id 154; 6 pages, 4 figures, see the PoS website for the full resolution versio
    corecore