362 research outputs found

    Primary total knee arthroplasty in the management of epiphyseal fracture around the knee

    Get PDF
    SummaryIntroductionOver the past few years the use of arthroplasty was broadened to treating complex epiphyseal fractures at the shoulder and elbow joints. Similar trends to treat this type of fractures at the knee are less documented. Based on a multicenter retrospective series study, the aims of this work is to evaluate the short term clinical results of total knee prostheses in the management of comminuted epiphyseal fractures around the knee, to identify the technical issues and fine tune the indications.Material and methodsFollowing the initiative of the French Hip and Knee Society (SFHG) and the Traumatology Study Group (GETRAUM), 26 charts from eight different centers in France were included in this multicenter retrospective series. Inclusion criteria were: primary total knee arthroplasty (TKA) in the management of complex articular fractures involving the proximal end of the tibia or distal end of the femur. Surgical features were identified and complications were analyzed. The assessment protocol at last follow-up was standardized and included patient demographic data, analysis of the Parker and IKS scores.ResultsDuring the immediate postoperative period, six patients (23%) reported a general complication and four patients (15%) a local arthroplasty-related complication. At last follow-up (mean 16.2 months), the overall final Parker score was 6.3 (a mean decrease of 1.7) and the mean IKS knee score was 82 points for a mean function score of 54 points.DiscussionPrimary TKA is a suitable management option for complex fractures in autonomous elderly patients suffering from knee osteoarthritis. The key technical details of this procedure should be respected and meticulously planned to achieve optimal results and limit the risk of complications. This risk in these acute complex fractures remains higher than after conventional TKA but comparable to that observed after TKA for post-traumatic arthritis.Level of evidenceIV; retrospective cohort study

    Developing a machine learning algorithm to predict the probability of aseptic loosening of the glenoid component after anatomical total shoulder arthroplasty:protocol for a retrospective, multicentre study

    Get PDF
    INTRODUCTION: Despite technological advancements in recent years, glenoid component loosening remains a common complication after anatomical total shoulder arthroplasty (ATSA) and is one of the main causes of revision surgery. Increasing emphasis is placed on the prevention of glenoid component failure. Previous studies have successfully predicted range of motion, patient-reported outcomes and short-term complications after ATSA using machine learning methods, but an accurate predictive model for (glenoid component) revision is currently lacking. This study aims to use a large international database to accurately predict aseptic loosening of the glenoid component after ATSA using machine learning algorithms.METHODS AND ANALYSIS: For this multicentre, retrospective study, individual patient data will be compiled from previously published studies reporting revision of ATSA. A systematic literature search will be performed in Medline (PubMed) identifying all studies reporting outcomes of ATSA. Authors will be contacted and invited to participate in the Machine Learning Consortium by sharing their anonymised databases. All databases reporting revisions after ATSA will be included, and individual patients with a follow-up less than 2 years or a fracture as the indication for ATSA will be excluded. First, features (predictive variables) will be identified using a random forest feature selection. The resulting features from the compiled database will be used to train various machine learning algorithms (stochastic gradient boosting, random forest, support vector machine, neural network and elastic-net penalised logistic regression). The developed and validated algorithms will be evaluated across discrimination (c-statistic), calibration, the Brier score and the decision curve analysis. The best-performing algorithm will be used to create an open-access online prediction tool.ETHICS AND DISSEMINATION: Data will be collected adhering to the WHO regulation on data sharing. An Institutional Review Board review is not applicable. The study results will be published in a peer-reviewed journal.</p

    LO-phonon assisted polariton lasing in a ZnO based microcavity

    Full text link
    Polariton relaxation mechanisms are analysed experimentally and theoretically in a ZnO-based polariton laser. A minimum lasing threshold is obtained when the energy difference between the exciton reservoir and the bottom of the lower polariton branch is resonant with the LO phonon energy. Tuning off this resonance increases the threshold, and exciton-exciton scattering processes become involved in the polariton relaxation. These observations are qualitatively reproduced by simulations based on the numerical solution of the semi-classical Boltzmann equations

    Field-effect control of superconductivity and Rashba spin-orbit coupling in top-gated LaAlO3/SrTiO3 devices

    Full text link
    The recent development in the fabrication of artificial oxide heterostructures opens new avenues in the field of quantum materials by enabling the manipulation of the charge, spin and orbital degrees of freedom. In this context, the discovery of two-dimensional electron gases (2-DEGs) at LAlO3/SrTiO3 interfaces, which exhibit both superconductivity and strong Rashba spin-orbit coupling (SOC), represents a major breakthrough. Here, we report on the realisation of a field-effect LaAlO3/SrTiO3 device, whose physical properties, including superconductivity and SOC, can be tuned over a wide range by a top-gate voltage. We derive a phase diagram, which emphasises a field-effect-induced superconductor-to-insulator quantum phase transition. Magneto-transport measurements indicate that the Rashba coupling constant increases linearly with electrostatic doping. Our results pave the way for the realisation of mesoscopic devices, where these two properties can be manipulated on a local scale by means of top-gates

    Patterned silicon substrates: a common platform for room temperature GaN and ZnO polariton lasers

    Full text link
    A new platform for fabricating polariton lasers operating at room temperature is introduced: nitride-based distributed Bragg reflectors epitaxially grown on patterned silicon substrates. The patterning allows for an enhanced strain relaxation thereby enabling to stack a large number of crack-free AlN/AlGaN pairs and achieve cavity quality factors of several thousands with a large spatial homogeneity. GaN and ZnO active regions are epitaxially grown thereon and the cavities are completed with top dielectric Bragg reflectors. The two structures display strong-coupling and polariton lasing at room temperature and constitute an intermediate step in the way towards integrated polariton devices

    Comparison of the influence of corneo-scleral and scleral lenses on ocular surface and tear film metrics in a presbyopic population

    Get PDF
    PURPOSE: To assess and compare the effect of the corneo-scleral lenses (C-ScL) and scleral lenses (ScL) on tear film parameters and central corneal thickness (CCT) in healthy presbyopic subjects. METHODS: Thirty subjects wore two contact lenses (CLs), randomly assigned, of neutral power, but of different diameters, 12.7mm (C-ScL) and 18mm (ScL) and being equal in the others parameters: material (HS100) and centre thickness (0.29mm). At baseline, 20min after insertion and at 8h, the tear meniscus area (TMA) and CCT was measured (with optical coherence tomography) as well as tear osmolarity. RESULTS: TMA revealed statistical differences for both lenses at 20min (p<0.001), and also at 8h (p=0.003), being greater for the C-ScL. CCT showed statistical differences for both lenses at 20min (p=0.002), and also at 8h (p=0.001), being lower for the C-ScL. Osmolarity did not reveal statistical differences at 20min (p=0.29), while it was statistically different at 8h (p=0.03), being lower for the C-ScL. CONCLUSIONS: C-ScL lead to a lesser reduction in the TMA and a lower induced hypoxic stress than the ScL. Osmolarity levels remained within normal values across the day with no clinical difference between lenses. Both designs can represent a good optical platform for correcting presbyopia as well as protecting the ocular surface by vaulting the cornea

    Flemish Normative Data for the Buschke Selective Reminding Test

    Get PDF
    The purpose of this study was to provide normative data for a Flemish version of the Buschke Selective Reminding Test (SRT). The SRT allows for the simultaneous analysis of several components of verbal memory, such as short and long term retrieval. The Flemish SRT was administered to 3257 neurologically healthy adults (1627 men and 1630 women, age range = 18–94 years). Effects of age, sex and education on SRT performance were assessed. Results indicate that SRT performance decreased with age and that this decline accelerated in men compared to women. Furthermore, an effect of education was found favoring participants who completed a higher education. Normative data quantified through percentile ranks and stratified by age, sex and education level are provided
    corecore