129 research outputs found

    The Relationship between Eating Behaviors of Children and Mothers, and Nutritional Status of Children

    Get PDF
    Introduction: Parents have a significant impact on child nutrition and the child's eating habits in long-term behavior. This study aims to examine the effects of mothers' attitudes on the eating behaviors of children and the determination of their nutritional status.Method: Children's eating habits and mothers' eating attitudes were examined in 417 children with face-to-face interviews using the Child Feeding Questionnaire (CFQ). The participants' anthropometric characteristics were determined, and body mass indexes (kg/m2) were calculated. AnthroPlus software was used to determine the children's BMI-for-age Z-scores. BeBiS nutrition information system was used to assess children's food intake.Results: The mothers' median BMI was above the overweight threshold. The lowest CFQ score was for perceived child weight, and the maximum score was for food restriction. Significant differences were found in mothers ages, mothers' BMIs, children's WAZ and BAZ scores, and BMIs, weight (p<0.001), perceived parent weight scores (p=0.04), and pressure to eat (p=0.04). Families should be conscious about nutrition for the protection and promotion of children's health

    Electrospun nanofiber membranes for adsorption of dye molecules from textile wastewater

    Get PDF
    The nanofiber membranes prepared by the electrospinning method have unique properties such as high specific surface area and high porosity with fine pores. These properties led electrospun nanofiber membranes to use for the removal of dye molecules from textile wastewater. In this study, a hydrophobic Thermoplastic Polyurethane (TPU) and a hydrophilic Poly (vinyl alcohol) (PVA) were selected for producing electrospun nanofibers and their sorption capacities were investigated. The largest sorption capacity reached to maximum 88.31 mg/g, belong to BTCA cross-linked PVA membranes due to hydrophilic character of PVA. Contrary to expectation, hydrophobic character of TPU was dominant and incorporation of CD to the TPU nanofibers did not affect the sorption of the TPU membranes, and showed very low adsorption capacity (14.48 mg/g). © Published under licence by IOP Publishing Ltd

    Laser treatment in diabetic retinopathy

    Get PDF
    Diabetic retinopathy is a leading cause of visual impairment and blindness in developed countries due to macular edema and proliferative diabetic retinopathy (PDR). For both complications laser treatment may offer proven therapy: the Diabetic Retinopathy Study demonstrated that panretinal scatter photocoagulation reduces the risk of severe visual loss by >= 50% in eyes with high-risk characteristics. Pan-retinal scatter coagulation may also be beneficial in other PDR and severe nonproliferative diabetic retinopathy (NPDR) under certain conditions. For clinically significant macular edema the Early Treatment of Diabetic Retinopathy Study could show that immediate focal laser photocoagulation reduces the risk of moderate visual loss by at least 50%. When and how to perform laser treatment is described in detail, offering a proven treatment for many problems associated with diabetic retinopathy based on a high evidence level. Copyright (c) 2007 S. Karger AG, Basel

    Intravitreal vs. subtenon triamcinolone acetonide for the treatment of diabetic cystoid macular edema

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To assess the efficacy of the intravitreal (IVT) injection of Triamcinolone Acetonide (TA) as compared to posterior subtenon (SBT) capsule injection for the treatment of cystoid diabetic macular edema.</p> <p>Methods</p> <p>Fourteen patients with type II diabetes mellitus and on insulin treatment, presenting diffuse cystoid macular edema were recruited. Before TA injection all focal lakes were treated by laser photocoagulation. In the same patients one eye was assigned to 4 mg IVT injection of TA and the fellow eye was then treated with 40 mg SBT injection of TA. Before and one, three and six months after treatment we measured visual acuity with ETDRS chart as well as thickness of the macula with optical coherence tomography (OCT) and intraocular pressure (IOP).</p> <p>Results</p> <p>The eyes treated with an IVT injection displayed significant improvement in visual acuity, both after one (0.491 ± 0.070; p < 0.001) and three months (0.500 ± 0.089; p < 0.001) of treatment. Significant improvement was displayed also in eyes treated with an SBT injection, again after one (0.455 ± 0.069; p < 0.001) and three months (0.427 ± 0.065; p < 0.001). The difference between an IVT injection (0.809 ± 0.083) and SBT injection (0.460 ± 0.072) becomes significant six months after the treatment (p < 0.001).</p> <p>Macular thickness of the eyes treated with IVT injection was significantly reduced both after one (222.7 ± 13.4 μm; p < 0.001) and after three months (228.1 ± 10.6 μm; p < 0.001) of treatment. The eyes treated with SBT injection displayed significant improvement after one (220.1 ± 15.1 μm; p < 0.001) and after three months (231.3 ± 10.9 μm; p < 0.001). The difference between the eyes treated with IVT injection (385.2 ± 11.3 μm) and those treated with SBT injection (235.4 ± 8.7 μm) becomes significant six months after the treatment (p < 0.001).</p> <p>Intraocular pressure of the eyes treated with IVT injection significantly increased after one month (17.7 ± 1.1 mm/Hg; p < 0.020), three (18.2 ± 1.2 mm/Hg; p < 0.003) and six month (18.1 ± 1.3 mm/Hg; p < 0.007) when compared to baseline value (16.1 ± 1.402 mm/Hg). In the SBT injection eyes we didn't display a significant increase of intraocular pressure after one (16.4 ± 1.2 mm/Hg; p < 0.450), three (16.3 ± 1.1 mm/Hg; p < 0.630) and six months (16.2 ± 1.1 mm/Hg; p < 0.720) when compared to baseline value (16.2 ± 1.3 mm/Hg).</p> <p>Conclusion</p> <p>The parabulbar subtenon approach can be considered a valid alternative to the intravitreal injection.</p> <p>Trial registration</p> <p>Current Controlled Trials <b>ISRCTN67086909</b></p

    A comprehensive overview of radioguided surgery using gamma detection probe technology

    Get PDF
    The concept of radioguided surgery, which was first developed some 60 years ago, involves the use of a radiation detection probe system for the intraoperative detection of radionuclides. The use of gamma detection probe technology in radioguided surgery has tremendously expanded and has evolved into what is now considered an established discipline within the practice of surgery, revolutionizing the surgical management of many malignancies, including breast cancer, melanoma, and colorectal cancer, as well as the surgical management of parathyroid disease. The impact of radioguided surgery on the surgical management of cancer patients includes providing vital and real-time information to the surgeon regarding the location and extent of disease, as well as regarding the assessment of surgical resection margins. Additionally, it has allowed the surgeon to minimize the surgical invasiveness of many diagnostic and therapeutic procedures, while still maintaining maximum benefit to the cancer patient. In the current review, we have attempted to comprehensively evaluate the history, technical aspects, and clinical applications of radioguided surgery using gamma detection probe technology

    Corticosteroids in ophthalmology : drug delivery innovations, pharmacology, clinical applications, and future perspectives

    Get PDF

    Akciǧer Kanserinde 7. Tnm Evrelemesinden 8.'Ye Doǧru

    No full text
    Scopu

    Nonlinear Schrödinger equation with growing potential on infinite metric graphs

    No full text
    The paper deals with nonlinear Schrödinger equations on infinite metric graphs. We assume that the linear potential is infinitely growing. We prove an existence and multiplicity result that covers both self-focusing and defocusing cases. Furthermore, under some additional assumptions we show that solutions obtained bifurcate from trivial ones. We prove that these solutions are superexponentially localized. Our approach is variational and based on generalized Nehari manifold. © 2019 Elsevier Lt
    • …
    corecore