80 research outputs found

    Sample selection method for arbitrary fading emulation using mode-stirred chambers

    Get PDF
    Mode-stirred chambers (MSC) consist on one or more resonant cavities coupled in some way in order to allow the measurement of different antenna parameters such as antenna efficiency, correlation, diversity gain or MIMO capacity, among others. In a single-cavity mode-stirred chamber, also known as a reverberation chamber (RC), the environment is isotropic and the amplitude of the signal is Rayleigh distributed. Real environments, however, rarely follow an isotropic Rayleigh-fading scenario. Previous results have shown that a Rician-fading emulation can be obtained via hardware modification using an RC. The different methods lack from an accurate emulation performance and are strongly dependent upon chamber size and antenna configurations. With the innate complexity of more-than-one cavity MSC, the coupling structure generates sample sets which are complex enough so as to contain different clusters with diverse fading characteristics. This paper presents a novel method to accurately emulate a more realistic Rician-fading distribution from a Rayleigh-fading distribution by selecting parts of the sample set that forms different statistical ensembles using a complex two-cavity multi-iris-coupled MSC. Sample selection is performed using a genetic algorithm. Results demonstrate the potential of MSCs for versatile MIMO fading emulation and OTA testing. The method is patent protected by EMITE Ing.This work was supported in part by the Spanish National R&D Programme through TEC2008-05811 and by Fundación Séneca, the R&D coordinating agency for the Region of Murcia (Spain) under the 11783/PI/09 project

    Emulation of MIMO rician-fading environments with mode-stirred reverberation chambers

    Get PDF
    Some recent publications have extended the emulating capabilities of mode-stirred reverberation chambers, which are now able to emulate Ricean-fading and non-isotropic environments. Either the need to physically modify existing chambers or multiple sets of measurements is required for these enhancements. In this paper a novel post-processing hybrid tool is presented for the transformation of a Rayleigh-fading emulated environment into a Rician one. The model is tested and compared to outdoor measurements and simulations through the K-factor, correlation, diversity gain and MIMO capacity. Results show an excellent matching performance with no hardware modifications of mode-stirred chambers with just one set of measurements. The method is patent prot cted by EMITE Ing.This work was supported in part by Fundación Séneca, the R&D unit of the Autonomous Region of Murcia (Spain) under project reference 11783/PI/09 and in part by the Spanish National R&D Programme through TEC2008-05811. J. Valenzuela-Valdés is with the EMITE Ingeniería SLNE, Edificio CEEIM, E-30100 Espinardo, Murcia, Spain (e-mail: [email protected]). J. D. Sánchez-Heredia, A. M. Martínez-González, and D. A. Sánchez-Hernández are with the Departamento de Tecnologías de la Información y Comunicaciones, Universidad Politécnica de Cartagena, Cartagena E-30202, Spain (e-mail: [email protected])

    Advances in mode-stirred reverberation chambers for wireless communication performance evaluation

    Get PDF
    Reverberation chambers (RC) are a popular tool for laboratory wireless communication performance evaluation, and their sandardization for Over-The-Air (OTA) measurements is underway. Yet, the inherent limitations of singlecavity RCs to emulate isotropic Rayleigh-fading scenarios with uniform phase distribution and high elevation angular spread put their representation of realistic scenarios into jeopardy. Recent advances in the last few years, however, have solved all these limitations by using more general mode-stirred reverberation chambers (MSC), wherein the number of cavities, their stirring and coupling mechanisms, and their software postprocessing algorithms is far from simple, representing a new era for wireless communications research, development, and over-the-air testing. This article highlights recent advances in the development of second-generation mode-stirred chambers for wireless communications performance evaluatio

    MIMO TIS/TRP active testing with second-generation mode-stirred chambers

    Get PDF
    With the first 4G trials scheduled for 2010 and the compulsory use of MIMO into both WiMAX and LTE standards, MIMO technology has finally exploded. Mobile Internet Peripherals and Devices are said to take a market share of 30% of all handsets and non-handsets wireless devices by 2013. In this complex scenario, antenna engineering has gained a tremendous importance. While the use of multiple antennas in the base station or access point (AP) is usually feasible, user terminals have size and weight restrictions that make the use of conventional antenna elements such as dipoles or patch antennas problematic. Thus, novel array topologies and antenna elements for multi-antenna systems are of great interest. But not only new geometries and designs are required, but also the antenna engineer is faced with a novel way to evaluate performance. While the parameters to characterize antennas in general are well defined and worldwide accepted, the way to evaluate the performance of an antenna array for MIMO is still an open issue, since multiple new concepts have to be considered, such as pattern diversity, corrrelation among elements, fading environment or polarization diversity, among others. Typical active parameters being currently tested for 2G and 3G systems are Total Radiated Power (TRP) and Total Isotropic Sensitivity (TIS). 4G systems are already envisioned to require more complex active testing due their inherently embedded MIMO technology. In this article, the way of using a second generation mode-stirred chamber (EMITE Ing E300 MIMO Analyzer) connected to a rradiocommunications tester (Rohde & Schwarz CMU200) to characterize wireless devices by measuring TRP and TIS is decribed. Measurements have been perormed for the UMTS system, but are simply extende to other systems. Since second-generation mode-stirred chambers can emulate a wide variety of Rayleigh, Rician, isotropic and non-isotropic scenarios, the procedure described in this paper opens the door for more advanced evaluation of active parameters for a variety of fading scenarios, which is unheard of in the wireless communications arena.Ministerio de Educación y Cienci

    Training load and heart rate variability in acute exposure to hypobaric hypoxia: A case study

    Get PDF
    Objetivo: Analizar el control de la carga de entrenamientoen la estrategia de aclimatación empleada por dos atletas amateur (mujer y hombre) antes de una ascensión exitosa a 5460 metros. Metodología: Durante 195 días consecutivos se realizaron mediciones basales de variabilidad de la frecuencia cardiaca (VFC). Se obtuvieron cuatro muestras de sangre durante la semana previa al evento principal (Pre), inmediatamente antes de la ascensión (Pre A), después (Post A) y una semana de recuperación (Post C). Resultados:Los registros diarios de VFC matutinos parecen ser una forma útil para monitorizar el estado de equilibrio simpático-parasimpático en montañistas antes de abordar las sesiones de entrenamiento. Se observó que ambos sujetos aumentaron sus niveles de leucocitos y neutrófilos exhibiendo variaciones sobre 60% entre las condiciones pre A y post B. Eritrocitos, hematocrito y hemoglobina presentaron tras la exposición aguda a 5460 m disminuciones, lo que coincide conlas diferencias porcentuales en plaquetas entre ambos sujetos (-3% y -51%). Conclusiones: Los registros diarios de VFC matutinos y de 5 minutos de duración parecen ser una forma útil para monitorizar el estado de equilibrio simpático-parasimpático. Se observaron cambios significativos en algunas células de la serie blanca.Aim: To analyzethe control of training load for an acclimatization strategy employed by two amateur athletes (female and male) prior to a successful ascent to 5460 meters. Methodology:Baseline heart rate variability (HRV) measurements were taken for 195 consecutive days. Four blood samples were taken the week before the main event (Pre), pre-ascent (Pre A), post-ascent (Post A), and one-week post-ascent (Post C). Results:Daily morning HRV recordings were useful for monitoring the state of sympathetic-parasympathetic balance in mountaineers prior to tackling training sessions. Both subjects had increased leukocytes and neutrophil levels, exhibiting variations over 60% between pre-A and post-B conditions. Erythrocytes, hematocrit, and haemoglobin decreased after acute exposure to 5460 m, coinciding with changes in platelet levels between both subjects (-3% and -51%). Conclusions:Daily morning and 5-min HRV recordings are a useful way for monitoring the state of sympathetic-parasympathetic balance. Significant changes were observed in some white blood cells

    Carga de entrenamiento y variabilidad de la frecuencia cardiaca en una exposición aguda a la hipoxia hipobárica: Estudio de caso

    Get PDF
    Objetivo: Analizar el control de la carga de entrenamiento en la estrategia de aclimatación empleada por dos atletas amateur (mujer y hombre) antes de una ascensión exitosa a 5460 metros. Metodología: Durante 195 días consecutivos se realizaron mediciones basales de variabilidad de la frecuencia cardiaca (VFC). Se obtuvieron cuatro muestras de sangre durante la semana previa al evento principal (Pre), inmediatamente antes de la ascensión (Pre A), después (Post A) y una semana de recuperación (Post C). Resultados: Los registros diarios de VFC matutinos parecen ser una forma útil para monitorizar el estado de equilibrio simpático-parasimpático en montañistas antes de abordar las sesiones de entrenamiento. Se observó que ambos sujetos aumentaron sus niveles de leucocitos y neutrófilos exhibiendo variaciones sobre 60% entre las condiciones pre A y post B. Eritrocitos, hematocrito y hemoglobina presentaron tras la exposición aguda a 5460 m disminuciones, lo que coincide con las diferencias porcentuales en plaquetas entre ambos sujetos (-3% y -51%). Conclusiones: Los registros diarios de VFC matutinos y de 5 minutos de duración parecen ser una forma útil para monitorizar el estado de equilibrio simpático-parasimpático. Se observaron cambios significativos en algunas células de la serie blanca

    Complicaciones de la endocarditis infecciosa en un paciente con válvula aórtica bicúspide

    Get PDF
    We present a 50-year-old male with two-month history of constitutional syndrome diagnosed with subacute infective endocarditis due to susceptible Streptococcus sanguinis. Echocardiography revealed a bicuspid aortic valve with severe stenosis and regurgitation, a 13mm vegetation, a second vegetation in the mitral-aortic intervalvular fibrosa, abscess, and pseudoaneurysm. The CT scan was crucial in order to identify two peripheral embolisms and to anatomically define the perivalvular extension of the disease for the surgical planning. The patient underwent urgent surgery and subsequently developed complete atrioventricular block that required pacemaker implantation.Presentamos el caso de un varón de 50 años con síndrome constitucional de dos meses de evolución diagnosticado de endocarditis infecciosa subaguda por Streptococcus sanguinis sensible. En la ecocardiografía se objetivó una válvula aórtica bicúspide con estenosis e insuficiencia severas, una vegetación de 13mm, una segunda vegetación en la unión mitroaórtica, absceso y pseudoaneurisma. El TAC fue de relevante importancia al identificar dos embolias periféricas y definir anatómicamente la extensión perivalvular de la enfermedad de cara a la planificación quirúrgica. El paciente fue sometido a cirugía urgente y posteriormente desarrolló bloqueo auriculoventricular completo que precisó de implante de marcapasos

    Distancia natural de acoplamiento de una cabeza humana a una antena en la banda C de WiMAX

    Get PDF
    En esta contribución, un plano coronal de cabeza humana es expuesto a 4 W de potencia radiada por un dipolo de media onda a 5725 MHz, correspondientes a la Potencia Isotrópica Radiada Equivalente (PIRE) máxima permitida en la Banda C de WiMAX. Se proporcionan tanto la TAE (Tasa de Absorción Especifica) como los incrementos de temperatura asociados a la exposición electromagnética, para distintos escenarios. Se evalúa el efecto en el confort térmico de los procesos termorregulatorios humanos. Se presenta un importante efecto de adaptación entre el dipolo y la cabeza humana, así como al cráneo como protector del encéfalo ante tensiones térmicas debidas a exposición a campo EM Como resultado del estudio, se podrian derivar restricciones básicas más precisas combinando los límites de TAE con la respuesta térmica asociadaAsociación de Jóvenes Investigadores de Cartagena, (AJICT). Universidad Politécnica de Cartagena. Escuela Técnica Superior de Ingeniería Industrial UPCT, (ETSII). Escuela Técnica Superior de Ingeniería Agronómica, (ETSIA), Escuela Técnica Superior de Ingeniería de Telecomunicación (ETSIT). Escuela de Ingeniería de Caminos, Canales, y Puertos y de Ingeniería de Minas, (EICM). Fundación Séneca, Agencia Regional de Ciencia y Tecnología. Parque Tecnológico de Fuente Álamo. Grupo Aquilin

    Fibroelastoma en el ventrículo izquierdo: un hallazgo muy poco frecuente

    Get PDF
    The evaluation of cardiac masses is a relatively frequent clinical problem for cardiac imaging techniques. We present the case of a cardiac mass with an unusual location in which imaging techniques made it possible to guide the diagnosis, which, how could it be otherwise, was confirmed in surgery.La valoración de las masas cardíacas es un problema clínico relativamente frecuente para las técnicas de imagen cardíca. Presentamos el caso de una masa cardíaca con localización inusual en el que las técnicas de imagen permitieron orientar el diagnóstico, que como no puede ser de otro modo, se confirmó en la cirugía

    El Derecho a la intimidad: nuevos y viejos debates

    Get PDF
    En la presente publicación se abordan una serie de temas sobre el derecho a la intimidad que han sido y siguen siendo, por su importancia, debatidos tanto en la doctrina como en la jurisprudencia nacional como internacional. De este modo, se ha analizado, entre otros, el concepto del derecho a la intimidad, sus alcances, así como su reconocimiento en la constitución y los tratados y convenios internacionales tanto del ámbito europeo como americano. También se ha analizado la importancia del test de proporcionalidad para evitar que en el marco de una investigación penal las intervenciones corporales sean inconstitucionales o afecten el núcleo esencial del derecho a la intimidad.This publication addresses a series of topics on the right to privacy that have been and continue to be important in debate, both in national and international jurisprudence. In this way, it has been analyzed, among others, the concept of the right to privacy, its scope, as well as its recognition in the constitution and international treaties and conventions, both European and American. The importance of the proportionality test has also been analyzed to avoid that in the framework of a criminal investigation, corporal interventions are unconstitutional or affect the essential core of the right to privacy.Presentación / Juan José López Ortega (pp. 9-13). -- I. El derecho a la intimidad. 1. La utilización de medios técnicos de observación y vigilancia en la Lecrim (LO 13/15) / Juan José López Ortega (pp. 15-47). -- 2. Sobre el derecho fundamental a la intimidad. Breves reflexiones jurídicas / Manuel Alejandro Donato Ramírez (pp. 49-99). -- II. El derecho a la intimidad en la jurisprudencia constitucional y convencional: el Tribunal Constitucional español, el Tribunal Europeo de Derechos humanos y la Corte Interamericana de Derechos humanos. 3. El derecho a la intimidad en la Constitución española y la jurisprudencia del Tribunal Europeo de Derechos humano / Alejandro Jiménez Pérez (pp. 101-113). -- 4. La intimidad como parte de la dignidad del ser humano en el Convenio europeo de derechos humanos y la Convención americana de derechos humanos / Juan Diego Salon Piedra (pp. 115-130). -- III. El derecho a la intimidad y la investigación penal 5. El derecho a la intimidad y la investigación penal: una ponderación de derechos / Carlos Patricio Serrano (pp. 131-147). -- 6. El derecho a la intimidad como límite de las intervenciones corporales en el marco del proceso penal / Fredy Valenzuela Ylizarbe (pp. 149-164). -- 7. Las intervenciones corporales, la intimidad y otros derechos: especial referencia a las diligencias de cacheo / Gerson W. Camarena Aliaga y Ana Lucía Heredia Muñoz (pp. 165-180). -- IV. El derecho a la intimidad y las nuevas tecnologías 8. El derecho a la intimidad en el contexto de las nuevas tecnologías de comunicación e información / Zoila Macavilca Román (pp. 181-192).-- 9. El derecho a la intimidad y el nuevo delito de sexting / Miriam Sánchez Sánchez (pp. 193-208). -- 10. El derecho a la intimidad y la amenaza del terrorismo: una nueva configuración de la intimidad y su regulación / Carmen González Vaz (pp. 209-224)
    corecore