1,400 research outputs found
Discovery of Localized Regions of Excess 10-TeV Cosmic Rays
An analysis of 7 years of Milagro data performed on a 10-degree angular scale
has found two localized regions of excess of unknown origin with greater than
12 sigma significance. Both regions are inconsistent with gamma-ray emission
with high confidence. One of the regions has a different energy spectrum than
the isotropic cosmic-ray flux at a level of 4.6 sigma, and it is consistent
with hard spectrum protons with an exponential cutoff, with the most
significant excess at ~10 TeV. Potential causes of these excesses are explored,
but no compelling explanations are found.Comment: Submitted to PhysRevLet
TeV Gamma-Ray Sources from a Survey of the Galactic Plane with Milagro
A survey of Galactic gamma-ray sources at a median energy of ~20 TeV has been
performed using the Milagro Gamma Ray Observatory. Eight candidate sources of
TeV emission are detected with pre-trials significance in the
region of Galactic longitude and latitude
. Four of these sources, including the Crab nebula
and the recently published MGRO J2019+37, are observed with significances
after accounting for the trials involved in searching the 3800
square degree region. All four of these sources are also coincident with EGRET
sources. Two of the lower significance sources are coincident with EGRET
sources and one of these sources is Geminga. The other two candidates are in
the Cygnus region of the Galaxy. Several of the sources appear to be spatially
extended. The fluxes of the sources at 20 TeV range from ~25% of the Crab flux
to nearly as bright as the Crab.Comment: Submitted to Ap
Milagro Constraints on Very High Energy Emission from Short Duration Gamma-Ray Bursts
Recent rapid localizations of short, hard gamma-ray bursts (GRBs) by the
Swift and HETE satellites have led to the observation of the first afterglows
and the measurement of the first redshifts from this type of burst. Detection
of >100 GeV counterparts would place powerful constraints on GRB mechanisms.
Seventeen short duration (< 5 s) GRBs detected by satellites occurred within
the field of view of the Milagro gamma-ray observatory between 2000 January and
2006 December. We have searched the Milagro data for >100 GeV counterparts to
these GRBs and find no significant emission correlated with these bursts. Due
to the absorption of high-energy gamma rays by the extragalactic background
light (EBL), detections are only expected for redshifts less than ~0.5. While
most long duration GRBs occur at redshifts higher than 0.5, the opposite is
thought to be true of short GRBs. Lack of a detected VHE signal thus allows
setting meaningful fluence limits. One GRB in the sample (050509b) has a likely
association with a galaxy at a redshift of 0.225, while another (051103) has
been tentatively linked to the nearby galaxy M81. Fluence limits are corrected
for EBL absorption, either using the known measured redshift, or computing the
corresponding absorption for a redshift of 0.1 and 0.5, as well as for the case
of z=0.Comment: Accepted for publication in the Astrophysical Journa
The Study of TeV Variability and Duty Cycle of Mrk 421 from 3 Years of Observations with the Milagro Observatory
TeV flaring activity with time scales as short as tens of minutes and an
orphan TeV flare have been observed from the blazar Markarian 421 (Mrk 421).
The TeV emission from Mrk 421 is believed to be produced by leptonic
synchrotron self-Compton (SSC) emission. In this scenario, correlations between
the X-ray and the TeV fluxes are expected, TeV orphan flares are hardly
explained and the activity (measured as duty cycle) of the source at TeV
energies is expected to be equal or less than that observed in X-rays if only
SSC is considered. To estimate the TeV duty cycle of Mrk 421 and to establish
limits on its variability at different time scales, we continuously observed
Mrk 421 with the Milagro observatory. Mrk 421 was detected by Milagro with a
statistical significance of 7.1 standard deviations between 2005 September 21
and 2008 March 15. The observed spectrum is consistent with previous
observations by VERITAS. We estimate the duty cycle of Mrk 421 for energies
above 1 TeV for different hypothesis of the baseline flux and for different
flare selections and we compare our results with the X-ray duty cycle estimated
by Resconi et al. 2009. The robustness of the results is discussed.Comment: 27 pages, 6 figures, ApJ accepte
Evidence for TeV Emission from GRB 970417a
Milagrito, a detector sensitive to very high energy gamma rays, monitored the
northern sky from February 1997 through May 1998. With a large field of view
and a high duty cycle, this instrument was well suited to perform a search for
TeV gamma-ray bursts (GRBs). We report on a search made for TeV counterparts to
GRBs observed by BATSE. BATSE detected 54 GRBs within the field of view of
Milagrito during this period. An excess of events coincident in time and space
with one of these bursts, GRB 970417a, was observed by Milagrito. The excess
has a chance probability of of being a fluctuation of the
background. The probability for observing an excess at least this large from
any of the 54 bursts is . No significant correlations were
detected from the other bursts.Comment: 10 pages, 3 figure
Spectrum and Morphology of the Two Brightest Milagro Sources in the Cygnus Region: MGRO J2019+37 and MGRO J2031+41
The Cygnus region is a very bright and complex portion of the TeV sky, host
to unidentified sources and a diffuse excess with respect to conventional
cosmic-ray propagation models. Two of the brightest TeV sources, MGRO J2019+37
and MGRO J2031+41, are analyzed using Milagro data with a new technique, and
their emission is tested under two different spectral assumptions: a power law
and a power law with an exponential cutoff. The new analysis technique is based
on an energy estimator that uses the fraction of photomultiplier tubes in the
observatory that detect the extensive air shower. The photon spectrum is
measured in the range 1 to 200 TeV using the last 3 years of Milagro data
(2005-2008), with the detector in its final configuration. MGRO J2019+37 is
detected with a significance of 12.3 standard deviations (), and is
better fit by a power law with an exponential cutoff than by a simple power
law, with a probability % (F-test). The best-fitting parameters for the
power law with exponential cutoff model are a normalization at 10 TeV of
, a spectral
index of and a cutoff energy of TeV. MGRO
J2031+41 is detected with a significance of 7.3, with no evidence of a
cutoff. The best-fitting parameters for a power law are a normalization of
and a
spectral index of . The overall flux is subject to an
30% systematic uncertainty. The systematic uncertainty on the power law
indices is 0.1. A comparison with previous results from TeV J2032+4130,
MGRO J2031+41 and MGRO J2019+37 is also presented.Comment: 11 pages, 10 figure
The Intrinsic Origin of Spin Echoes in Dipolar Solids Generated by Strong Pi Pulses
In spectroscopy, it is conventional to treat pulses much stronger than the
linewidth as delta-functions. In NMR, this assumption leads to the prediction
that pi pulses do not refocus the dipolar coupling. However, NMR spin echo
measurements in dipolar solids defy these conventional expectations when more
than one pi pulse is used. Observed effects include a long tail in the CPMG
echo train for short delays between pi pulses, an even-odd asymmetry in the
echo amplitudes for long delays, an unusual fingerprint pattern for
intermediate delays, and a strong sensitivity to pi-pulse phase. Experiments
that set limits on possible extrinsic causes for the phenomena are reported. We
find that the action of the system's internal Hamiltonian during any real pulse
is sufficient to cause the effects. Exact numerical calculations, combined with
average Hamiltonian theory, identify novel terms that are sensitive to
parameters such as pulse phase, dipolar coupling, and system size.
Visualization of the entire density matrix shows a unique flow of quantum
coherence from non-observable to observable channels when applying repeated pi
pulses.Comment: 24 pages, 27 figures. Revised from helpful referee comments. Added
new Table IV, new paragraphs on pages 3 and 1
First results of a study of TeV emission from GRBs in Milagrito
Milagrito, a detector sensitive to γ-rays at TeV energies, monitored the northern sky during the period February 1997 through May 1998. With a large field of view and high duty cycle, this instrument was used to perform a search for TeV counterparts to γ-ray bursts. Within the Milagrito field of view 54 γ-ray bursts at keV energies were observed by the Burst And Transient Satellite Experiment (BATSE) aboard the Compton Gamma-Ray Observatory. This paper describes the results of a preliminary analysis to search for TeV emission correlated with BATSE detected bursts. Milagrito detected an excess of events coincident both spatially and temporally with GRB 970417a, with chance probability 2.8×10−5 within the BATSE error radius. No other significant correlations were detected. Since 54 bursts were examined the chance probability of observing an excess with this significance in any of these bursts is 1.5×10−3. The statistical aspects and physical implications of this result are discussed
Calibration of the Milagro Cosmic Ray Telescope
The Milagro detector is an air shower array which uses the water Cherenkov
technique and is capable of continuously monitoring the sky at energies near 1
TeV. The detector consists of 20000 metric tons of pure water instrumented with
723 photo-multiplier tubes (PMTs). The PMTs are arranged in a two-layer
structure on a lattice of 3 m spacing covering 5000 area. The direction
of the shower is determined from the relative timing of the PMT signals,
necessitating a common time reference and amplitude slewing corrections to
improve the time resolution. The calibration system to provide these consists
of a pulsed laser driving 30 diffusing light sources deployed in the pond to
allow cross-calibration of the PMTs. The system is capable of calibrating times
and the pulse-heights from the PMTs using the time-over-threshold technique.
The absolute energy scale is provided using single muons passing through the
detector. The description of the calibration system of the Milagro detector and
its prototype Milagrito will be presented.Comment: 4 pages, submitted to the XXVI International Cosmic Ray Conferenc
- …