1,395 research outputs found

    An innovative technique for the investigation of the 4-fold forbidden beta-decay of 50^{50}V

    Full text link
    For the first time a Vanadium-based crystal was operated as cryogenic particle detector. The scintillating low temperature calorimetric technique was used for the characterization of a 22 g YVO4_4 crystal aiming at the investigation of the 4-fold forbidden non-unique β−\beta^- decay of 50^{50}V. The excellent bolometric performance of the compound together with high light output of the crystal makes it an outstanding technique for the study of such elusive rate process. The internal radioactive contaminations of the crystal are also investigated showing that an improvement on the current status of material selection and purification are needed, 235/238^{235/238}U and 232^{232}Th are measured at the level of 28 mBq/kg, 1.3 Bq/kg and 28 mBq/kg, respectively. In this work, we also discuss a future upgrade of the experimental set-up which may pave the road for the detection of the rare 50^{50}V β−\beta^- decay

    Cryogenic light detectors with enhanced performance for rare events physics

    Full text link
    We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, and (3) it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath. We tested this new technique with a 16 cm2^2 Ge light detector with thermistor readout sitting on the surface of a large TeO2_2 bolometer. The light collection efficiency was increased by greater than 50\% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20~eV RMS that, together with increased light collection, enabled us to obtain the best α\alpha vs β/γ\beta/\gamma discrimination ever obtained with massive TeO2_2 crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.Comment: 6 pages, 4 figure

    Background suppression in massive TeO2_2 bolometers with Neganov-Luke amplified light detectors

    Full text link
    Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0νββ\nu\beta\beta). The observation of such decay would demonstrate the violation of lepton number, and at the same time it would necessarily imply that neutrinos have a Majorana character. The sensitivity of cryogenic detectors based on TeO2_2 is strongly limited by the alpha background in the region of interest for the 0νββ\nu\beta\beta of 130^{130}Te. It has been demonstrated that particle discrimination in TeO2_2 bolometers is possible measuring the Cherenkov light produced by particle interactions. However an event-by-event discrimination with NTD-based light detectors has to be demonstrated. We will discuss the performance of a highly-sensitive light detector exploiting the Neganov-Luke effect for signal amplification. The detector, being operated with NTD-thermistor and coupled to a 750 g TeO2_2 crystal, shows the ability for an event-by-event identification of electron/gamma and alpha particles. The extremely low detector baseline noise, RMS 19 eV, demonstrates the possibility to enhance the sensitivity of TeO2_2-based 0νββ\nu\beta\beta experiment to an unprecedented level

    Upgrading Monocytes Therapy for Critical Limb Ischemia Patient Treatment: Pre-Clinical and GMP-Validation Aspects

    Get PDF
    Advanced cell therapy medicinal products (ATMP) are at the forefront of a new range of biopharmaceuticals. The use of ATMP has evolved and increased in the last decades, representing a new approach to treating diseases that are not effectively managed with conventional treatments. The standard worldwide recognized for drug production is the Good Manufacturing Practices (GMP), widely used in the pharma production of synthesized drugs but applying also to ATMP. GMP guidelines are worldwide recognized standards to manufacture medicinal products to guarantee high quality, safety, and efficacy. In this report, we describe the pre-clinical and the GMP upgrade of peripheral blood mononuclear cell (PBMC) preparation, starting from peripheral blood and ending up with a GMP-grade clinical product ready to be used in patients with critical limb ischemia (CLI). We also evaluated production in hypoxic conditions to increase PBMC functional activity and angiogenic potential. Furthermore, we extensively analyzed the storage and transport conditions of the final product as required by the regulatory body for ATMPs. Altogether, results suggest that the whole manufacturing process can be performed for clinical application. Peripheral blood collected by a physician should be transported at room temperature, and PBMCs should be isolated in a clean room within 8 h of venipuncture. Frozen cells can be stored in nitrogen vapors and thawed for up to 12 months. PBMCs resuspended in 5% human albumin solution should be stored and transported at 4 degrees C before injection in patients within 24 h to thawing. Hypoxic conditioning of PBMCs should be implemented for clinical application, as it showed a significant enhancement of PBMC functional activity, in particular with increased adhesion, migration, and oxidative stress resistance. We demonstrated the feasibility and the quality of a GMP-enriched suspension of monocytes as an ATMP, tested in a clean room facility for all aspects related to production in respect of all the GMP criteria that allow its use as an ATMP. We think that these results could ease the way to the clinical application of ATMPs

    Dual career couples in academia, international mobility and dual career services in Europe

    Get PDF
    The number of dual career couples in academia is growing due to the increasing proportion of women with a doctoral degree and the greater propensity of women to choose another academic as their partner. At the same time, international mobility is required for career advancement in academia creating challenges for dual career couples where both partners pursue careers. This paper has two objectives: a) to raise the increasingly important issue of dual career couples in academia and the gendered effect that the pressure for mobility has on career advancement and work-life interference, and b) to present examples of recently established dual career services of higher education institutions in Germany, Denmark and Switzerland, responding to the needs of the growing population of dual career couples. Due to long established practices of dual career services in the US, the European examples will be compared with US practices. This paper raises the significance of considering dual career couples in institutional policies that aim for an internationally excellent and diversified academic workforce. It will appraise dual career services according to whether they reinforce or address gender inequalities and provide recommendations to HEIs interested in developing services and programmes for dual career couples

    Reducing the impact of radioactivity on quantum circuits in a deep-underground facility

    Get PDF
    As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor fifty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware
    • …
    corecore