265 research outputs found

    In vivo measurements of atrial repolarization alternans based on standard pacemaker technology

    Get PDF
    It has been shown that repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization above a critical heart rate and promotes susceptibility to ventricular arrhythmias. It is unknown whether repolarization alternans is measurable in the atria using standard pacemakers and whether it plays a role in promoting atrial fibrillation. In this work, atrial repolarization alternans amplitude and periodicity are studied in a sheep model of pacing-induced atrial fibrillation. Two pacemakers, each with one right atrial and ventricular lead, were implanted in 4 male sheep after ablation of the atrioventricular junction. The first one was used to deliver rapid pacing for measurements of right atrial repolarization alternans and the second one to record a unipolar electrogram. Atrial repolarization alternans appeared rate-dependent and its amplitude increased as a function of pacing rate. Repolarization alternans was intermittent but no periodicity was detected. An increase of repolarization alternans preceding episodes of non-sustained atrial fibrillation suggests that repolarization alternans is a promising parameter for assessment of atrial fibrillation susceptibility

    Animal model to compare the effects of suture technique on cross-sectional compliance on end-to-side anastomoses

    Get PDF
    Objective: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. Methods: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = π × mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC = δCSAA/δP where δP is the mean pulse pressure and δCSAA is the mean CSAA during cardiac cycle. Results: We collected a total of 1 200 000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94±0.4 mm2 and a mean CSAA in diastole of 26.30±0.5 mm2 (mean δCSAA was 0.64 mm2). CSAC for running suture was 4.5×10−6m2/kPa. For interrupted suture we had a mean CSAA in systole of 21.98±0.2 mm2 and a mean CSAA in diastole of 17.38±0.3 mm2 (mean δCSAA was 4.6±0.1 mm2). CSAC for interrupted suture was 11×10−6 m2/kPa. Conclusions: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo™ anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomose

    Acute ascending aortic dissection complicating open heart surgery: cerebral perfusion defines the outcome

    Get PDF
    Objective: This retrospective study was designed to assess the risks of acute ascending aorta dissection (AAD) as a rare but potentially fatal complication of open heart surgery. Method: Among 8624 cardiac surgical procedures under cardiopulmonary bypass (CPB) and cardioplegic myocardial protection from 1978 to 1997, 10 patients (0.12%) presented with a secondary or so called ‘iatrogenic' AAD. There were seven men and three women, mean age 64±9 years, ranging from 47 to 79. The original procedures involved five coronary artery bypass grafts (CABG), one repeat CABG, one aortic valve replacement (AVR), one AVR and CABG, one mitral valvuloplasty (MVP) and CABG and one ascending aorta replacement. We retrospectively analyzed their hospital records. Results: Group I consisted of seven patients with AAD intraoperatively and group II consisted of three patients who developed acute AAD 8-32 days after cardiac surgery. In group I, treatment consisted of the original procedure, plus grafting of the ascending aorta in six patients and closed plication and aortic wrapping in one. In group II, two patients received a dacron graft and one patient developed lethal tamponnade due to aortic rupture before surgery. Postoperatively, six patients responded well and three died (33%), two patients from group I on the 2nd postoperative day with severe post-anoxic encephalopathy, and one from group II with severe peroperative cardiogenic shock. Conclusion: Preventing AAD with the appropriate means remains standard practice in cardiac surgery. If AAD occurs, it requires prompt diagnosis and interposition graft to allow a better prognosis. Intraoperative AAD happens at the beginning of CPB jeopardizing perfusion of the supra-aortic arterie

    Evaluation of Ablation Patterns Using a Biophysical Model of Atrial Fibrillation

    Get PDF
    Atrial fibrillation (AF) is the most common form of cardiac arrhythmia. Surgical/Radiofrequency (RF) ablation is a therapeutic procedure that consists of creating lines of conduction block to interrupt AF. The present study evaluated 13 different ablation patterns by means of a biophysical model of the human atria. In this model, ablation lines were abruptly applied transmurally during simulated sustained AF, and success rate, time to AF termination and average beat-to-beat interval were documented. The gold standard Cox's Maze III procedure was taken as reference. The effectiveness of twelve less invasive patterns was compared to it. In some of these incomplete lines (entailing a gap) were simulated. Finally, the computer simulations were compared to clinical data. The results show that the model reproduces observations made in vivo: (1) the Maze III is the most efficient ablation procedure; (2) less invasive patterns should include lines in both right and left atrium; (3) incomplete ablation lines between the pulmonary veins and the mitral valve annulus lead to uncommon flutter; (4) computer simulations of incomplete lines are consistent with clinical results of non-transumural RF ablation. Biophysical modeling may therefore be considered as a useful tool for understanding the mechanisms underlying AF therapie

    Intermittent atrial tachycardia facilitates atrial fibrillation by a shortening of activation recovery interval

    Get PDF
    Introduction: We recently observed in a chronic ovine model that a shortening of action potential duration (APD) as assessed by the activation recovery interval (ARI) may be a mechanism whereby pacing-induced atrial tachycardia (PIAT) facilitates atrial fibrillation (AF), mediated by a return to 1:1 atrial capture after the effective refractory period has been reached. The aim of the present study is to evaluate the effect of long term intermittent burst pacing on ARI before induction of AF.Methods: We specifically developed a chronic ovine model of PIAT using two pacemakers (PM) each with a right atrial (RA) lead separated by ∼2cm. The 1st PM (Vitatron T70) was used to record a broadband unipolar RA EGM (800 Hz, 0.4 Hz high pass filter). The 2nd was used to deliver PIAT during electrophysiological protocols at decremental pacing CL (400 beats, from 400 to 110ms) and long term intermittent RA burst pacing to promote electrical remodeling (5s of burst followed by 2s of sinus rhythm) until onset of sustained AF. ARI was defined as the time difference between the peak of the atrial repolarization wave and the first atrial depolarization. The mean ARIs of paired sequences (before and after remodeling), each consisting of 20 beats were compared.Results: As shown in the figure, ARIs (n=4 sheep, 46 recordings) decreased post remodeling compared to baseline (86±19 vs 103±12 ms, p<0.05). There was no difference in atrial structure as assessed by light microscopy between control and remodeled sheep.Conclusions: Using standard pacemaker technology, atrial ARIs as a surrogate of APDs were successfully measured in vivo during the electrical remodeling process leading to AF. The facilitation of AF by PIAT mimicking salvos from pulmonary veins is heralded by a significant shortening of ARI

    Gefäßchirurgische Ausbildung in endovaskulärer Technik in Lausanne

    Get PDF
    Zusammenfassung: Zwischen 1995 und 2005 wuchs die Anzahl der jährlich von uns mit endovaskulären Techniken versorgten Aortenaneurysmen (EVAR) von 0 auf 50, und dies auf allen Stufen der Aorta. Zu unserer Organisation gehören ein breites Team von Chirurgen, ein Lager mit 3kompletten Familien von Endoprothesen (gerade Endoprothesen, konische Endoprothesen, und Bifurkationen), ein mobiler Wagen mit Zubehör (Einführungsbestecke, Führungsdrähte, Katheter, Ballone etc.) und ein Apparat auf Rädern für die intravaskuläre Ultraschalluntersuchung (IVUS). Letzterer erlaubt es zusammen mit einer mobilen Durchleuchtungsanlage (C-Bogen), in jedem Operationssaal unserer Institution endovaskulär Aneurysmen zu analysieren, und dies in der Regel ohne Angiographie bzw. Kontrastmittel. Deshalb sind wir nicht mehr auf eine ausgiebige bildgebende präoperative Abklärung potenzieller Kandidaten für eine endovaskuläre Sanierung von Aneurysmen angewiesen und können rupturierte Aneurysmen der Bauchaorta oder der thorakalen Aorta ohne Verzug behandeln. Bei der endovaskulären Sanierung von Aortenaneurysmen unterscheiden wir zwischen Prozessschritten (Indikationsstellung, Darstellung der Zugangsgefäße, Ausmessen mittels IVUS und Roadmapping mittels Durchleuchtung, Implantatwahl, Implantatinsertion, Positionierung, Implantatabwurf, Erfolgsbeurteilung, Rekonstruktion der Zugangsgefäße und Nachkontrolle) und Kompetenzstufen (Assistent, Oberarzt, Leitender Arzt). Unsere ultraschallgestützte Technik zur endovaskulären Sanierung von Aneurysmen wurde mittels IVUS-Transporter und Telementoring erfolgreich auch anderen Institutionen zur Verfügung gestell

    Acute ascending aortic dissection complicating open heart surgery: cerebral perfusion defines the outcome

    Get PDF
    OBJECTIVE: This retrospective study was designed to assess the risks of acute ascending aorta dissection (AAD) as a rare but potentially fatal complication of open heart surgery. METHOD: Among 8624 cardiac surgical procedures under cardiopulmonary bypass (CPB) and cardioplegic myocardial protection from 1978 to 1997, 10 patients (0.12%) presented with a secondary or so called 'iatrogenic' AAD. There were seven men and three women, mean age 64 +/- 9 years, ranging from 47 to 79. The original procedures involved five coronary artery bypass grafts (CABG), one repeat CABG, one aortic valve replacement (AVR), one AVR and CABG, one mitral valvuloplasty (MVP) and CABG and one ascending aorta replacement. We retrospectively analyzed their hospital records. RESULTS: Group I consisted of seven patients with AAD intraoperatively and group II consisted of three patients who developed acute AAD 8-32 days after cardiac surgery. In group I, treatment consisted of the original procedure, plus grafting of the ascending aorta in six patients and closed plication and aortic wrapping in one. In group II, two patients received a dacron graft and one patient developed lethal tamponnade due to aortic rupture before surgery. Postoperatively, six patients responded well and three died (33%), two patients from group I on the 2nd postoperative day with severe post-anoxic encephalopathy, and one from group II with severe peroperative cardiogenic shock. CONCLUSION: Preventing AAD with the appropriate means remains standard practice in cardiac surgery. If AAD occurs, it requires prompt diagnosis and interposition graft to allow a better prognosis. Intraoperative AAD happens at the beginning of CPB jeopardizing perfusion of the supra-aortic arteries

    Aorto-subclavian thromboembolism: a rare complication associated with moderate ovarian hyperstimulation syndrome

    Get PDF
    The case of an arterial aorto-subclavian thromboembolism associated with a moderate ovarian hyperstimulation syndrome (OHSS) and following ovulation induction for in-vitro fertilization in a young woman is reported. Because of the lack of response to systemic thrombolysis, a left postero-lateral thoracotomy was performed on day 8 after embryo transfer. A fibrinocruoric embolus situated at the junction of the left subclavian artery from the aorta was removed through a left subclavian arteriotomy. The distal axillary embolus was removed by a retrograde balloon catheter embolectomy. A moderate OHSS was observed. The ovarian stimulation and OHSS-related risks of thromboembolism are discussed. We conclude that, in the absence of risk factors, counselling about possible complications resulting from stimulation must be emphasized
    corecore