112 research outputs found
Collateral donor artery physiology and the influence of a chronic total occlusion on fractional flow reserve
Background— The presence of a concomitant chronic total coronary occlusion (CTO) and a large collateral contribution might alter the fractional flow reserve (FFR) of an interrogated vessel, rendering the FFR unreliable at predicting ischemia should the CTO vessel be revascularized and potentially affecting the decision on optimal revascularization strategy. We tested the hypothesis that donor vessel FFR would significantly change after percutaneous coronary intervention of a concomitant CTO. Methods and Results— In consecutive patients undergoing percutaneous coronary intervention of a CTO, coronary pressure and flow velocity were measured at baseline and hyperemia in proximal and distal segments of both nontarget vessels, before and after percutaneous coronary intervention. Hemodynamics including FFR, absolute coronary flow, and the coronary flow velocity–pressure gradient relation were calculated. After successful percutaneous coronary intervention in 34 of 46 patients, FFR in the predominant donor vessel increased from 0.782 to 0.810 (difference, 0.028 [0.012 to 0.044]; P=0.001). Mean decrease in baseline donor vessel absolute flow adjusted for rate pressure product: 177.5 to 139.9 mL/min (difference −37.6 [−62.6 to −12.6]; P=0.005), mean decrease in hyperemic flow: 306.5 to 272.9 mL/min (difference, −33.5 [−58.7 to −8.3]; P=0.011). Change in predominant donor vessel FFR correlated with angiographic (%) diameter stenosis severity (r=0.44; P=0.009) and was strongly related to stenosis severity measured by the coronary flow velocity–pressure gradient relation (r=0.69; P<0.001). Conclusions— Recanalization of a CTO results in a modest increase in the FFR of the predominant collateral donor vessel associated with a reduction in coronary flow. A larger increase in FFR is associated with greater coronary stenosis severity
Recommended from our members
Large area, low capacitance Si(Li) detectors for high rate x-ray applications
Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication procedures, I-V and C-V characteristics, noise performance, and spectral response to 2-60 keV x-rays are described
Germanium Blocked Impurity Band (BIB) detectors
Information is given in viewgraph form. The advantages of the Si blocked impurity band (BIB) detector invented by M. D. Petroff and M. G. Stabelbroek are noted: smaller detection volume leading to a reduction of cosmic ray interference, extended wavelength response because of dopant wavefunction overlap, and photoconductive gain of unity. It is argued that the stated advantages of Si BIB detectors should be realizable for Ge BIB detectors. Information is given on detector development, subtrate choice and preparation, wafer polising, epitaxy, characterization of epi layers, and preliminary Ge BIB detector test results
Recommended from our members
A Sixteen Channel Peak Sensing ADC for Singles Spectra in the FERA Format
To read out multi-element small X-ray detectors for X-ray fluorescence application with synchrotron radiation one needs the capability to record multiple singles spectra for each detector element at high rates. We have developed a sixteen channel 11 bit peak sensing ADC in a CAMAC module. We use the FERA readout bus to place the data into a commercially available histogramming module developed to generate multiple histograms from FERA ADCs. The sixteen channels digitize shaped pulses from the detectors without external gating. The digitizing time is 8 {mu}sec, the peak acquisition time is {>=} 2 {mu}sec. The module contains a LiFO to permit block transfers in order to minimize dead times associated with the readout. There is a common CAMAC controlled analog threshold for noise suppression and a 16 bit mask to enable or disable individual ADCs. Differential non-linearity is less than +8% / -4%. A {gamma}-ray spectrum collected using this ADC is presented
Old Plants, New Tricks:Phenological Research Using Herbarium Specimens
The timing of phenological events, such as leaf-out and flowering, strongly influence plant success and their study is vital to understanding how plants will respond to climate change. Phenological research, however, is often limited by the temporal, geographic, or phylogenetic scope of available data. Hundreds of millions of plant specimens in herbaria worldwide offer a potential solution to this problem, especially as digitization efforts drastically improve access to collections. Herbarium specimens represent snapshots of phenological events and have been reliably used to characterize phenological responses to climate. We review the current state of herbarium-based phenological research, identify potential biases and limitations in the collection, digitization, and interpretation of specimen data, and discuss future opportunities for phenological investigations using herbarium specimens
Mythology as history Theories of origins and formulations of the past in the works of Shelley
SIGLEAvailable from British Library Document Supply Centre- DSC:D77589 / BLDSC - British Library Document Supply CentreGBUnited Kingdo
- …