480 research outputs found

    Ten Year Operating Test Results and Post-Test Analysis of a 1/10 Segment Stirling Sodium Heat Pipe, Phase III

    Get PDF
    High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described

    Improved Thin, Flexible Heat Pipes

    Get PDF
    Flexible heat pipes of an improved type are fabricated as layers of different materials laminated together into vacuum- tight sheets or tapes. In comparison with prior flexible heat pipes, these flexible heat pipes are less susceptible to leakage. Other advantages of these flexible heat pipes, relative to prior flexible heat pipes, include high reliability and greater ease and lower cost of fabrication. Because these heat pipes are very thin, they are highly flexible. When coated on outside surfaces with adhesives, these flexible heat pipes can be applied, like common adhesive tapes, to the surfaces of heat sinks and objects to be cooled, even if those surfaces are curved

    Post-Test Analysis of a 10-Year Sodium Heat Pipe Life Test

    Get PDF
    High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 years) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described. Lessons learned and future life test plans are also discussed

    An Overview of Long Duration Sodium Heat Pipe Tests

    Get PDF
    High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed

    City-level air quality improvement in the Beijing-Tianjin-Hebei region from 2016/17 to 2017/18 heating seasons: Attributions and process analysis

    Get PDF
    With the implementation of clean air strategies, PM_(2.5) pollution abatement has been observed in the “2 + 26” cities in the Beijing-Tianjin-Hebei (BTH) region (referred to as the BTH2+26) and their surrounding areas. To identify the drivers for PM_(2.5) concentration decreases in the BTH2+26 cites from the 2016/17 heating season (HS1617) to the 2017/18 heating season (HS1718), we investigated the contributions of meteorological conditions and emission-reduction measures by Community Multi-Scale Air Quality (CMAQ) model simulations. The source apportionments of five sector sources (i.e., agriculture, industry, power plants, traffic and residential), and regional sources (i.e., local, within-BTH: other cities within the BTH2+26 cities, outside-BTH, and boundary conditions (BCON)) to the PM_(2.5) decreases in the BTH2+26 cities were estimated with the Integrated Source Apportionment Method (ISAM). Mean PM_(2.5) concentrations in the BTH2+26 cities substantially decreased from 77.4 to 152.5 μg m⁻³ in HS1617 to 52.9–101.9 μg m⁻³ in HS1718, with the numbers of heavy haze (daily PM_(2.5) ≥150 μg m⁻³) days decreasing from 17-77 to 5–30 days. The model simulation results indicated that the PM_(2.5) concentration decreases in most of the BTH2+26 cities were attributed to emission reductions (0.4–55.0 μg m⁻³, 2.3–81.6% of total), but the favorable meteorological conditions also played important roles (1.9–25.4 μg m⁻³, 18.4–97.7%). Residential sources dominated the PM_(2.5) reductions, leading to decreases in average PM_(2.5) concentrations by more than 30 μg m⁻³ in severely polluted cities (i.e., Shijiazhuang, Baoding, Xingtai, and Beijing). Regional source analyses showed that both local and within-BTH sources were significant contributors to PM_(2.5) concentrations for most cities. Emission controls in local and within-BTH sources in HS1718 decreased the average PM_(2.5) concentrations by 0.1–47.2 μg m⁻³ and 0.3–22.1 μg m⁻³, respectively, relative to those in HS1617. Here we demonstrate that a combination of favorable meteorological conditions and anthropogenic emission reductions contributed to the improvement of air quality from HS1617 to HS1718 in the BTH2+26 cities

    Hard-core Yukawa model for two-dimensional charge stabilized colloids

    Full text link
    The hyper-netted chain (HNC) and Percus-Yevick (PY) approximations are used to study the phase diagram of a simple hard-core Yukawa model of charge-stabilized colloidal particles in a two-dimensional system. We calculate the static structure factor and the pair distribution function over a wide range of parameters. Using the statics correlation functions we present an estimate for the liquid-solid phase diagram for the wide range of the parameters.Comment: 7 pages, 9figure
    corecore