196 research outputs found

    Adaptive feedback analysis and control of programmable stimuli for assessment of cerebrovascular function

    No full text
    The assessment of cerebrovascular regulatory mechanisms often requires flexibly controlled and precisely timed changes in arterial blood pressure (ABP) and/or inspired CO2. In this study, a new system for inducing variations in mean ABP was designed, implemented and tested using programmable sequences and programmable controls to induce pressure changes through bilateral thigh cuffs. The system is also integrated with a computer-controlled switch to select air or a CO2/air mixture to be provided via a face mask. Adaptive feedback control of a pressure generator was required to meet stringent specifications for fast changes, and accuracy in timing and pressure levels applied by the thigh cuffs. The implemented system consists of a PC-based signal analysis/control unit, a pressure control unit and a CO2/air control unit. Initial evaluations were carried out to compare the cuff pressure control performances between adaptive and non-adaptive control configurations. Results show that the adaptive control method can reduce the mean error in sustaining target pressure by 99.57 % and reduce the transient time in pressure increases by 45.21 %. The system has proven a highly effective tool in ongoing research on brain blood flow control

    Revisiting the frequency domain: the multiple and partial coherence of cerebral blood flow velocity in the assessment of dynamic cerebral autoregulation

    Get PDF
    Despite advances in modelling dynamic autoregulation, only part of the variability of cerebral blood flow velocity (CBFV) in the low frequency range has been explained. We investigate whether a multivariate representation can be used for this purpose. Pseudorandom sequences were used to inflate thigh cuffs and to administer 5% CO2. Multiple and partial coherence were estimated, using arterial blood pressure (ABP), end-tidal CO2 (EtCO2) and resistance area product as input and CBFV as output variables. The inclusion of second and third input variables increased the amount of CBFV variability that can be accounted for (p  <  10−4 in both cases). Partial coherence estimates in the low frequency range (<0.07 Hz) were not influenced by the use of thigh cuffs, but CO2 administration had a statistically significant effect (p  <  10−4 in all cases). We conclude that the inclusion of additional inputs of a priori known physiological significance can help account for a greater amount of CBFV variability and may represent a viable alternative to more conventional non-linear modelling. The results of partial coherence analysis suggest that dynamic autoregulation and CO2 reactivity are likely to be the result of different physiological mechanisms

    Detection of impaired cerebral autoregulation improves by increasing arterial blood pressure variability

    No full text
    Although the assessment of dynamic cerebral autoregulation (CA) based on measurements of spontaneous fluctuations in arterial blood pressure (ABP) and cerebral blood flow (CBF) is a convenient and much used method, there remains uncertainty about its reliability. We tested the effects of increasing ABP variability, provoked by a modification of the thigh cuff method, on the ability of the autoregulation index to discriminate between normal and impaired CA, using hypercapnia as a surrogate for dynamic CA impairment. In 30 healthy volunteers, ABP (Finapres) and CBF velocity (CBFV, transcranial Doppler) were recorded at rest and during 5% CO(2) breathing, with and without pseudo-random sequence inflation and deflation of bilateral thigh cuffs. The application of thigh cuffs increased ABP and CBFV variabilities and was not associated with a distortion of the CBFV step response estimates for both normocapnic and hypercapnic conditions (P=0.59 and P=0.96, respectively). Sensitivity and specificity of CA impairment detection were improved with the thigh cuff method, with the area under the receiver-operator curve increasing from 0.746 to 0.859 (P=0.031). We conclude that the new method is a safe, efficient, and appealing alternative to currently existing assessment methods for the investigation of the status of CA

    Coherent averaging of pseudorandom binary stimuli: is the dynamic cerebral autoregulatory response symmetrical?

    Get PDF
    Objective: Previous studies on cerebral autoregulation have shown the existence of hemispheric symmetry, which may be altered in stroke and traumatic brain injury. There is a paucity of data however on whether the response is symmetrical between those disturbances that cause cerebral hyperperfusion, to those that cause hypoperfusion. Our aim was to investigate whether the responses of cerebral autoregulation to haemodynamic stimuli of different directions are symmetrical. &#13; Approach: Using a previously described assessment method, we employed coherent averaging of the cerebral blood flow velocity (CBFV) responses to thigh cuff inflation and deflation, as driven by pseudorandom binary sequences, whilst simultaneously altering the inspired CO2. The symmetry of the autoregulatory response was assessed with regards to two parameters, its speed and gain. Using the first harmonic method, critical closing pressure (CrCP) and resistance area product (RAP) were estimated, and the gain of the autoregulatory response was calculated by performing linear regression between the coherent averages of arterial blood pressure (ABP) and CBFV, ABP and CrCP and finally ABP and RAP. A two-way repeated measures ANOVA was used to assess for the effect of the direction of change in ABP and the method of CO2 administration. &#13; Main results: Our results suggest that whilst the direction of ABP change does not have a significant effect, the effect of CO2 administration method is highly significant (p&lt;10-4). &#13; Significance: This is the first report to report to demonstrate the symmetry of the autoregulatory response to stimuli of different directions as well as the short term dynamics of RAP and CrCP under intermittent and constant hypercapnia. As haemodynamic stimulus direction does not appear to have an influence, our findings validate previous work done using different assessment methods

    Determinants of the dynamic cerebral critical closing pressure response to changes in mean arterial pressure

    Get PDF
    Objective. Cerebral critical closing pressure (CrCP) represents the value of arterial blood pressure (BP) where cerebral blood flow (CBF) becomes zero. Its dynamic response to a step change in mean BP (MAP) has been shown to reflect CBF autoregulation, but robust methods for its estimation are lacking. We aim to improve the quality of estimates of the CrCP dynamic response. Approach. Retrospective analysis of 437 healthy subjects (aged 18–87 years, 218 males) baseline recordings with measurements of cerebral blood velocity in the middle cerebral artery (MCAv, transcranial Doppler), non-invasive arterial BP (Finometer) and end-tidal CO2 (EtCO2, capnography). For each cardiac cycle CrCP was estimated from the instantaneous MCAv-BP relationship. Transfer function analysis of the MAP and MCAv (MAP-MCAv) and CrCP (MAP-CrCP) allowed estimation of the corresponding step responses (SR) to changes in MAP, with the output in MCAv (SRVMCAv) representing the autoregulation index (ARI), ranging from 0 to 9. Four main parameters were considered as potential determinants of the SRVCrCP temporal pattern, including the coherence function, MAP spectral power and the reconstruction error for SRVMAP, from the other three separate SRs. Main results. The reconstruction error for SRVMAP was the main determinant of SRVCrCP signal quality, by removing the largest number of outliers (Grubbs test) compared to the other three parameters. SRVCrCP showed highly significant (p < 0.001) changes with time, but its amplitude or temporal pattern was not influenced by sex or age. The main physiological determinants of SRVCrCP were the ARI and the mean CrCP for the entire 5 min baseline period. The early phase (2–3 s) of SRVCrCP response was influenced by heart rate whereas the late phase (10–14 s) was influenced by diastolic BP. Significance. These results should allow better planning and quality of future research and clinical trials of novel metrics of CBF regulation

    Dynamic cerebral autoregulation reproducibility is affected by physiological variability

    Get PDF
    Parameters describing dynamic cerebral autoregulation (DCA) have limited reproducibility. In an international, multi-center study, we evaluated the influence of multiple analytical methods on the reproducibility of DCA. Fourteen participating centers analyzed repeated measurements from 75 healthy subjects, consisting of 5 min of spontaneous fluctuations in blood pressure and cerebral blood flow velocity signals, based on their usual methods of analysis. DCA methods were grouped into three broad categories, depending on output types: (1) transfer function analysis (TFA); (2) autoregulation index (ARI); and (3) correlation coefficient. Only TFA gain in the low frequency (LF) band showed good reproducibility in approximately half of the estimates of gain, defined as an intraclass correlation coefficient (ICC) of > 0.6. None of the other DCA metrics had good reproducibility. For TFA-like and ARI-like methods, ICCs were lower than values obtained with surrogate data (p less than 0.05). For TFA-like methods, ICCs were lower for the very LF band (gain 0.38 ± 0.057, phase 0.17 ± 0.13) than for LF band (gain 0.59 ± 0.078, phase 0.39 ± 0.11, p ? 0.001 for both gain and phase). For ARI-like methods, the mean ICC was 0.30 ± 0.12 and for the correlation methods 0.24 ± 0.23. Based on comparisons with ICC estimates obtained from surrogate data, we conclude that physiological variability or non-stationarity is likely to be the main reason for the poor reproducibility of DCA parameters. Copyright © 2019 Sanders, Elting, Panerai, Aries, Bor-Seng-Shu, Caicedo, Chacon, Gommer, Van Huffel, Jara, Kostoglou, Mahdi, Marmarelis, Mitsis, Müller, Nikolic, Nogueira, Payne, Puppo, Shin, Simpson, Tarumi, Yelicich, Zhang and Claassen

    Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    Get PDF
    BACKGROUND: Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI) of Arterial Wall Motion (AWM) and to quantify simple wall motion indices in normal and diseased carotid arteries. METHODS: 224 normal and diseased carotid arteries (0–100% stenoses) were imaged in 126 patients (age 25–88 years, mean 68 ± 11). Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. RESULTS: AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. CONCLUSION: Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI
    • …
    corecore