274 research outputs found

    Time-Resolved Measurement of Interatomic Coulombic Decay in Ne_2

    Get PDF
    The lifetime of interatomic Coulombic decay (ICD) [L. S. Cederbaum et al., Phys. Rev. Lett. 79, 4778 (1997)] in Ne_2 is determined via an extreme ultraviolet pump-probe experiment at the Free-Electron Laser in Hamburg. The pump pulse creates a 2s inner-shell vacancy in one of the two Ne atoms, whereupon the ionized dimer undergoes ICD resulting in a repulsive Ne^{+}(2p^{-1}) - Ne^{+}(2p^{-1}) state, which is probed with a second pulse, removing a further electron. The yield of coincident Ne^{+} - Ne^{2+} pairs is recorded as a function of the pump-probe delay, allowing us to deduce the ICD lifetime of the Ne_{2}^{+}(2s^{-1}) state to be (150 +/- 50) fs in agreement with quantum calculations.Comment: 5 pages, 3 figures, accepted by PRL on July 11th, 201

    Effects of donor/recipient human leukocyte antigen mismatch on human cytomegalovirus replication following liver transplantation.

    Get PDF
    Background Natural immunity against cytomegalovirus (CMV) can control virus replication after solid organ transplantation; however, it is not known which components of the adaptive immune system mediate this protection. We investigated whether this protection requires human leukocyte antigen (HLA) matching between donor and recipient by exploiting the fact that, unlike transplantation of other solid organs, liver transplantation does not require HLA matching, but some donor and recipient pairs may nevertheless be matched by chance. Methods To further investigate this immune control, we determined whether chance HLA matching between donor (D) and recipient (R) in liver transplants affected a range of viral replication parameters. Results In total, 274 liver transplant recipients were stratified according to matches at the HLA A, HLA B, and HLA DR loci. The incidence of CMV viremia, kinetics of replication, and peak viral load were similar between the HLA matched and mismatched patients in the D+/R+ and D−/R+ transplant groups. D+/R− transplants with 1 or 2 mismatches at the HLA DR locus had a higher incidence of CMV viremia >3000 genomes/mL blood compared to patients matched at this locus (78% vs. 17%; P = 0.01). Evidence was seen that matching at the HLA A locus had a small effect on peak viral loads in D+/R− patients, with median peak loads of 3540 and 14,706 genomes/mL in the 0 and combined (1 and 2) mismatch groups, respectively (P = 0.03). Conclusion Overall, our data indicate that, in the setting of liver transplantation, prevention of CMV infection and control of CMV replication by adaptive immunity is minimally influenced by HLA matching of the donor and recipient. Our data raise questions about immune control of CMV in the liver and also about the cells in which the virus is amplified to give rise to CMV viremia

    Nondipole Effects in the Photoionization of Xe 4d5/2 and 4d3/2: Evidence for Quadrupole Satellites

    Full text link
    Measurements of nondipole parameters in spin-orbit-resolved Xe 4d photoionization demonstrate dynamical differences arising from relativistic effects. The experimental data do not agree with relativistic random-phase approximation calculations of single ionization dipole and quadrupole channels. It is suggested that the discrepancy is due to the omission of multiple-excitation quadrupole channels, i.e., quadrupole satellite transitions

    High-repetition-rate and high-photon-flux 70 eV high-harmonic source for coincidence ion imaging of gas-phase molecules

    Full text link
    Unraveling and controlling chemical dynamics requires techniques to image structural changes of molecules with femtosecond temporal and picometer spatial resolution. Ultrashort-pulse x-ray free-electron lasers have significantly advanced the field by enabling advanced pump-probe schemes. There is an increasing interest in using table-top photon sources enabled by high-harmonic generation of ultrashort-pulse lasers for such studies. We present a novel high-harmonic source driven by a 100 kHz fiber laser system, which delivers 1011^{11} photons/s in a single 1.3 eV bandwidth harmonic at 68.6 eV. The combination of record-high photon flux and high repetition rate paves the way for time-resolved studies of the dissociation dynamics of inner-shell ionized molecules in a coincidence detection scheme. First coincidence measurements on CH3_3I are shown and it is outlined how the anticipated advancement of fiber laser technology and improved sample delivery will, in the next step, allow pump-probe studies of ultrafast molecular dynamics with table-top XUV-photon sources. These table-top sources can provide significantly higher repetition rates than the currently operating free-electron lasers and they offer very high temporal resolution due to the intrinsically small timing jitter between pump and probe pulses

    Charge transfer in dissociating iodomethane and fluoromethane molecules ionized by intense femtosecond X-ray pulses

    Get PDF
    Citation: Boll, R., Erk, B., Coffee, R., Trippel, S., Kierspel, T., Bomme, C., . . . Rudenko, A. (2016). Charge transfer in dissociating iodomethane and fluoromethane molecules ionized by intense femtosecond X-ray pulses. Structural Dynamics, 3(4). doi:10.1063/1.4944344Additional Authors: Marchenko, T.;Miron, C.;Patanen, M.;Osipov, T.;Schorb, S.;Simon, M.;Swiggers, M.;Techert, S.;Ueda, K.;Bostedt, C.;Rolles, D.;Rudenko, A.Ultrafast electron transfer in dissociating iodomethane and fluoromethane molecules was studied at the Linac Coherent Light Source free-electron laser using an ultraviolet-pump, X-ray-probe scheme. The results for both molecules are discussed with respect to the nature of their UV excitation and different chemical properties. Signatures of long-distance intramolecular charge transfer are observed for both species, and a quantitative analysis of its distance dependence in iodomethane is carried out for charge states up to I21+. The reconstructed critical distances for electron transfer are in good agreement with a classical over-the-barrier model and with an earlier experiment employing a near-infrared pump pulse. © 2016 Author(s)

    Identification of absolute geometries of cis and trans molecular isomers by Coulomb Explosion Imaging

    Get PDF
    Citation: Ablikim, U., Bomme, C., Xiong, H., Savelyev, E., Obaid, R., Kaderiya, B., . . . Rolles, D. (2016). Identification of absolute geometries of cis and trans molecular isomers by Coulomb Explosion Imaging. Scientific Reports, 6, 8. doi:10.1038/srep38202An experimental route to identify and separate geometric isomers by means of coincident Coulomb explosion imaging is presented, allowing isomer-resolved photoionization studies on isomerically mixed samples. We demonstrate the technique on cis/trans 1,2-dibromoethene (C2H2Br2). The momentum correlation between the bromine ions in a three-body fragmentation process induced by bromine 3d inner-shell photoionization is used to identify the cis and trans structures of the isomers. The experimentally determined momentum correlations and the isomer-resolved fragment-ion kinetic energies are matched closely by a classical Coulomb explosion model

    Coupled motion of Xe clusters and quantum vortices in He nanodroplets

    Get PDF
    Citation: Jones, C. F., Bernando, C., Tanyag, R. M. P., Bacellar, C., Ferguson, K. R., Gomez, L. F., . . . Vilesov, A. F. (2016). Coupled motion of Xe clusters and quantum vortices in He nanodroplets. Physical Review B - Condensed Matter and Materials Physics, 93(18). doi:10.1103/PhysRevB.93.180510Additional Authors: Erk, B.;Foucar, L.;Hartmann, R.;Neumark, D. M.;Epp, S. W.;Englert, L.;Siefermann, K. R.;Weise, F.;Rudek, B.;Sturm, F. P.;Ullrich, J.;Bostedt, C.;Gessner, O.;Vilesov, A. F.Single He nanodroplets doped with Xe atoms are studied via ultrafast coherent x-ray diffraction imaging. The diffraction images show that rotating He nanodroplets about 200 nm in diameter contain a small number of symmetrically arranged quantum vortices decorated with Xe clusters. Unexpected large distances of the vortices from the droplet center (?0.7-0.8 droplet radii) are explained by a significant contribution of the Xe dopants to the total angular momentum of the droplets and a stabilization of widely spaced vortex configurations by the trapped Xe clusters. © 2016 American Physical Society
    • …
    corecore