1,166 research outputs found

    Tribological behaviour of copper oxide nanoparticle suspension

    Get PDF
    This work presents and discusses the tribological behaviour of nanoparticle suspensions in a polyalphaolefin (PAO6). CuO nanoparticles were separately dispersed at 0.5, 1.0 and 2.0% wt. in PAO6 using an ultrasonic probe for 2 minutes. AW properties were obtained using a TE53SLIM tribometer with a block-on-ring configuration and EP properties were obtained using a Four-Ball machine according to ASTM D2783. Wear surfaces were analyzed by SEM and EDS after tests. The study led to the following conclusions: nanoparticle suspensions exhibited reductions in friction and wear compared to the base oil; CuO suspensions showed the highest friction coefficient and lowest wear per nanoparticle content of 2%; all concentrations of nanoparticles improved the EP properties of PAO6; CuO showed better results at 0.5% wt. of nanoparticles; and the antiwear mechanism of nanoparticulate additive was produced by tribo-sintering

    Viscosity and tribology of copper oxide nanofluids

    Get PDF
    Nanofluids, a term proposed by Choi in 1995 [1], are composites consisting of solid nanoparticles with sizes varying generally from 1 to 100 nm dispersed in a liquid. Numerous nanoparticles used as oil additives have been investigated in recent years [2-7]. Results show that they deposit on the rubbing surface and improve the tribological properties of the base oil, displaying good friction and wear reduction characteristics even at concentrations below 2%wt. Although the viscosity of the nanofluids is a property of crucial importance for film forming, and hence friction and wear reduction, which are characteristic of lubricants, only Hwang et al. [8] have studied thermal characteristics, kinematic viscosity and tribological properties of nanofluids simultaneously. In this paper, we present measurements of dynamic viscosity of nanofluids formed by copper oxide nanoparticles dispersed in a polyalphaolefin, for temperatures and concentrations varying from 20 to 60ÂşC and 0.5 to 2% wt., respectively. Dependence of the nanofluid viscosity to the solid fraction and temperature was compared with existing models and its influence on lubrication was also analysed

    Tribological behavior of oils additised with a phosphonium-derived ionic liquid compared to a commercial oil

    Get PDF
    Purpose: The purpose of this paper is to study the antifriction, antiwear and tribolayer formation properties of the trihexyltetradecylphosphonium bis(2,4,4-trimethylpentyl) phosphinate ionic liquid (IL) as additive at 1 wt.% in two base oils and their mixtures, comparing the results with those of a commercial oil. Design/methodology/approach: The mixture of the base oils used in the formulation of the commercial oil SAE 0W20 plus the IL was tested under rolling/sliding and reciprocating conditions to determine the so-called Stribeck curve, the tribolayer formation and the antifriction and antiwear behaviors. Findings: The use of this IL as additive in these oils does not change their viscosity; improves the antifriction and antiwear properties of the base oils, making equal or outperforming these properties of the SAE 0W20; and the thickness and formation rate of the tribolayer resulting from the IL-surface interaction is highly dependent on the type of base oil and influence on the friction and wear results. Originality/value: The use of this IL allows to replace partial or totally commercial antifriction and antiwear additives. Peer review: The peer review history for this article is available at: https://publons.com/publon/10.1108/ILT-05-2020-0179/

    Corrosion activity and solubility in polar oils of three bis(trifluoromethylsulfonyl) imide/bis(trifluoromethylsulfonyl) amide ([NTF2]) anion-based ionic liquids.

    Get PDF
    The corrosion behaviour and solubility of three bis(trifluoromethylsulfonyl)amide1 ([NTf2]) anion-based ionic liquids: 1-dodecyl-3-methylimidazolium bis(trifluoromethylsulfonyl)amide ([C12MIM][NTf2]), tributylmethylammonium bis(trifluoromethylsulfonyl)amide ([N4441][NTf2]), and methyltrioctylammonium bis(trifluoromethylsulfonyl)amide ([N1888][NTf2]), as a component in a mixture with different base oils were analysed. Six polar oils suitable for use in lubrication were utilized as base oil. Solubility tests were performed by using turbidimetry, and corrosion was checked at 4 v/v% by examining the roughness and chemical composition of the surface after 21 days. The results showed that long carbon chains in the cation improve the solubility greatly in diesters and slightly in polyolesters. Corrosion was not detected at this concentration

    Lubrication performance of an ammonium cation-based ionic liquid used as an additive in a polar oil.

    Get PDF
    This paper studies the tribological behavior of the ionic liquid methyltrioctylammonium bis(trifluoromethylsulfonyl)imide ([N 1888 ][NTf 2 ]) as additive at different concentrations (1.25, 2.50, 3.75 and 5.00 wt%) in a polar base oil (diester). A tribometer using a ball-on-disk reciprocating configuration under fully flooded lubrication was used at a frequency of 15 Hz, at three different loads (40, 80 and 120 N), stroke length of 4 mm, and duration of 45 min. Worn surface on the disk was studied by confocal microscopy, SEM and XPS. Main results showed similar coefficient of friction for all lubricant samples; but different wear results were found at different loads, probably related with the chemical states found for fluorine on the worn surface and the temperature-dependent adsorption-desorption processes

    Tribological performance of three fatty acid anion-based ionic liquids (FAILs) used as lubricant additive

    Get PDF
    This paper studies the tribological behavior of three fatty acid anion-based ionic liquids: methyltrioctylammonium octanoate ([N8881][C8:0]), methyltrioctylammonium laurate ([N8881][C12:0]) and methyltrioctylammonium palmitate ([N8881][C16:0]) used as additive at 0.5, 1 and 2 wt% in an ester base oil. The tribological experiments were performed in two different tribometers: a Bruker UMT-3 using a reciprocating “ball-on-disc” configuration for pure sliding tests and a Mini Traction Machine (MTM) for rolling/sliding tests. After sliding tests, the wear scar was analyzed by scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) and X-ray photoelectron spectroscopy (XPS). Sliding tests results showed both friction and wear reduction of the mixtures with respect to the ester only at 25 °C. The worse tribological behavior at 100 °C could be attributed to the moderate thermal stability of these ionic liquids. Under rolling/sliding conditions, samples displayed similar antifriction and ECR behavior than the base oil at high speeds, changing to a higher friction and lower ECR at low speeds and increasing temperatures. EDX analysis showed mainly the steel disc elements. The XPS oxygen signal showed higher amount of C[dbnd]O bond on the worn surface after reciprocating tests at 25 °C, which could be attributable to IL-surface interaction and can explain the better wear reduction performance

    Friction, wear and corrosion behavior of environmentally-friendly fatty acid ionic liquids

    Get PDF
    © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This research deals with the tribological behavior and corrosion performance of three novel fatty acid anion-based ionic liquids (FAILs): methyltrioctylammonium hexanoate ([N8,8,8,1 ][C6:0 ]), methyltrioctylammonium octadecanoate ([N8,8,8,1 ][C18:0 ]) and methyltrioctylammonium octadec-9-enoate ([N8,8,8,1 ][C18:1 ]), employed for the first time as neat lubricant with five different material pairs: steel–steel, steel–aluminum alloy, steel–bronze, steel–cast iron and steel–tungsten carbide. These novel substances were previously obtained from fatty acids via metathesis reactions, identified struc-turally via NMR (nuclear magnetic resonance) and FTIR (Fourier-transform infrared spectroscopy) techniques, and then characterized from a physicochemical (density, water solubility, viscosity, viscosity index and refractive index) and environmental (bacterial toxicity and biodegradability) points of view. The corrosion behavior of the three FAILs was studied by exposure at room temperature, while friction and wear tests were performed with a reciprocating ball-on-disc configuration. The main results and conclusions obtained were: (1) Corrosion in the presence of the three FAILs is observed only on the bronze surface; (2) All FAILs presented similar tribological behavior as lubricants for each tested material pair; (3) XPS (X-ray photoelectron spectroscopy) analysis indicated that the surface behavior of the three FAILs in each material pair was similar, with low chemical interaction with the surfaces

    Lubrication Properties of the Ionic Liquid Dodecyl-3 Methylimidazolium bis(trifluoromethylsulfonyl)imide

    Get PDF
    © 2017, Springer Science+Business Media, LLC, part of Springer Nature. The ionic liquid (IL) dodecyl-3 methylimidazolium bis(trifluoromethylsulfonyl)imide was tested as neat lubricant and as additive (at 1 and 4 wt%) in a polar oil (diester). Tribological tests were performed using a reciprocating configuration for 90 min at 30 and 70 N, 10 Hz, 4 mm stroke length, and at room temperature and 100 °C. Wear volume and surface–IL interaction were determined by confocal microscopy, SEM, and XPS. The main findings were: Neat ionic liquid showed the best tribological behavior; the IL-containing mixtures had similar behavior than the base oil at the lower load; meanwhile, the mixture with 4 wt% of IL outperformed the antiwear behavior of the neat base oil at the higher load; surface–IL chemical interaction was found mainly at 100 °C

    Endoscopical and pathological dissociation in severe colitis induced by immune-checkpoint inhibitors

    Get PDF
    Checkpoint inhibitors have improved the survival of patients with advanced tumors and show a manageable toxicity profile. However, auto-immune colitis remains a relevant side effect, and combinations of anti-PD1/PDL1 and anti-CTLA-4 increase its incidence and severity. Here, we report the case of a 50-year-old patient diagnosed with stage IV cervical cancer that relapsed following radical surgery, external radiation/brachytherapy and standard chemotherapy. She was subsequently treated with Nivolumab and Ipilimumab combination and developed grade 2 colitis presenting a dissociation between endoscopic and pathological findings. At cycle 10 the patient reported grade 3 diarrhea and abdominal discomfort, without blood or mucus in the stools. Immunotherapy was withheld and a colonoscopy was performed, showing normal mucosa in the entire colon. Puzzlingly, histologic evaluation of randomly sampled mucosal biopsy of the distal colon showed an intense intraepithelial lymphocyte infiltration with crypt loss and some regenerating crypts with a few apoptotic bodies set in a chronically inflamed lamina propria, consistent with the microscopic diagnosis of colitis. Treatment with methylprednisolone 2 mg/kg was initiated which led to a decrease in the number of stools to grade 1. Additional investigations to exclude other causes of diarrhea rendered negative results. The patient experienced a major partial response and, following the resolution of diarrhea, she was re-challenged again with immunotherapy, with the reappearance of grade 2 diarrhea, leading to permanent immunotherapy interruption. We conclude and propose that performing random colonic biopsies should be considered in cases of immune checkpoint-associated unexplained diarrhea, even when colonoscopy shows macroscopically normal colonic mucosa inflammatory lesions
    • …
    corecore