485 research outputs found

    Negative parental responses to coming out and family functioning in a sample of lesbian and gay young adults

    Get PDF
    Parental responses to youths' coming out (CO) are crucial to the subsequent adjustment of children and family. The present study investigated the negative parental reaction to the disclosure of same-sex attraction and the differences between maternal and paternal responses, as reported by their homosexual daughters and sons. Participants' perceptions of their parents' reactions (evaluated through the Perceived Parental Reactions Scale, PPRS), age at coming out, gender, parental political orientation, and religiosity involvement, the family functioning (assessed through the Family Adaptability and Cohesion Evaluation Scales, FACES IV), were assessed in 164 Italian gay and lesbian young adults. Pearson correlation coefficients were calculated to assess the relation between family functioning and parental reaction to CO. The paired sample t-test was used to compare mothers and fathers' scores on the PPRS. Hierarchical multiple regression was conducted to analyze the relevance of each variable. No differences were found between mothers and fathers in their reaction to the disclosure. The analysis showed that a negative reaction to coming out was predicted by parents' right-wing political conservatism, strong religious beliefs, and higher scores in the scales Rigid and Enmeshed. Findings confirm that a negative parental reaction is the result of poor family resources to face a stressful situation and a strong belief in traditional values. These results have important implications in both clinical and social fields

    An in vitro study comparing a peripherally inserted central catheter to a conventional central venous catheter: no difference in static and dynamic pressure transmission

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Early goal directed therapy improves survival in patients with septic shock. Central venous pressure (CVP) monitoring is essential to guide adequate resuscitation. Use of peripherally inserted central catheters (PICC) is increasing, but little data exists comparing a PICC to a conventional CVP catheter. We studied the accuracy of a novel PICC to transmit static and dynamic pressures <it>in vitro</it>.</p> <p>Methods</p> <p>We designed a device to generate controlled pressures via a column of water allowing simultaneous measurements from a PICC and a standard triple lumen catheter. Digital transducers were used to obtain all pressure readings. Measurements of static pressures over a physiologic range were recorded using 5Fr and 6Fr dual lumen PICCs. Additionally, random repetitive pressure pulses were applied to the column of water to simulate physiologic intravascular pressure variations. The resultant PICC and control waveforms were recorded simultaneously.</p> <p>Results</p> <p>Six-hundred thirty measurements were made using the 5 Fr and 6 Fr PICCs. The average bias determined by Bland-Altman plot was 0.043 mmHg for 5 Fr PICC and 0.023 mmHg for 6 Fr PICC with a difference range of 1.0 to -1.0. The correlation coefficient for both catheters was 1.0 (p-value < 0.001). Dynamic pressure waveforms plotted simultaneously between PICC and control revealed equal peaks and troughs.</p> <p>Conclusion</p> <p><it>In vitro</it>, no static or dynamic pressure differences were found between the PICC and a conventional CVP catheter. Clinical studies are required to assess whether the novel PICC has bedside equivalence to conventional catheters when measuring central venous pressures.</p

    The prognosis of allocentric and egocentric neglect : evidence from clinical scans

    Get PDF
    We contrasted the neuroanatomical substrates of sub-acute and chronic visuospatial deficits associated with different aspects of unilateral neglect using computed tomography scans acquired as part of routine clinical diagnosis. Voxel-wise statistical analyses were conducted on a group of 160 stroke patients scanned at a sub-acute stage. Lesion-deficit relationships were assessed across the whole brain, separately for grey and white matter. We assessed lesions that were associated with behavioural performance (i) at a sub-acute stage (within 3 months of the stroke) and (ii) at a chronic stage (after 9 months post stroke). Allocentric and egocentric neglect symptoms at the sub-acute stage were associated with lesions to dissociated regions within the frontal lobe, amongst other regions. However the frontal lesions were not associated with neglect at the chronic stage. On the other hand, lesions in the angular gyrus were associated with persistent allocentric neglect. In contrast, lesions within the superior temporal gyrus extending into the supramarginal gyrus, as well as lesions within the basal ganglia and insula, were associated with persistent egocentric neglect. Damage within the temporo-parietal junction was associated with both types of neglect at the sub-acute stage and 9 months later. Furthermore, white matter disconnections resulting from damage along the superior longitudinal fasciculus were associated with both types of neglect and critically related to both sub-acute and chronic deficits. Finally, there was a significant difference in the lesion volume between patients who recovered from neglect and patients with chronic deficits. The findings presented provide evidence that (i) the lesion location and lesion size can be used to successfully predict the outcome of neglect based on clinical CT scans, (ii) lesion location alone can serve as a critical predictor for persistent neglect symptoms, (iii) wide spread lesions are associated with neglect symptoms at the sub-acute stage but only some of these are critical for predicting whether neglect will become a chronic disorder and (iv) the severity of behavioural symptoms can be a useful predictor of recovery in the absence of neuroimaging findings on clinical scans. We discuss the implications for understanding the symptoms of the neglect syndrome, the recovery of function and the use of clinical scans to predict outcome

    NuSTAR and XMM-Newton observations of NGC 1365: Extreme absorption variability and a constant inner accretion disk

    Get PDF
    We present a spectral analysis of four coordinated NuSTAR+XMM-Newton observations of the Seyfert galaxy NGC 1365. These exhibit an extreme level of spectral variability, which is primarily due to variable line-of-sight absorption, revealing relatively unobscured states in this source for the first time. Despite the diverse range of absorption states, each of the observations displays the same characteristic signatures of relativistic reflection from the inner accretion disk. Through time-resolved spectroscopy we find that the strength of the relativistic iron line and the Compton reflection hump relative to the intrinsic continuum are well correlated, as expected if they are two aspects of the same broadband reflection spectrum. We apply self-consistent disk reflection models to these time-resolved spectra in order to constrain the inner disk parameters, allowing for variable, partially covering absorption to account for the vastly different absorption states observed. Each of the four observations is treated independently to test the consistency of the results obtained for the black hole spin and the disk inclination, which should not vary on observable timescales. We find both the spin and the inclination determined from the reflection spectrum to be consistent, confirming NGC 1365 hosts a rapidly rotating black hole; in all cases the dimensionless spin parameter is constrained to be a* > 0.97 (at 90% statistical confidence or better)

    Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients

    Get PDF
    Background: Monitoring of cardiac output and blood pressure are standard procedures in critical care medicine. Traditionally, invasive techniques like pulmonary artery catheter (PAC) and arterial catheters are widely used. Invasiveness bears many risks of deleterious complications. Therefore, a noninvasive reliable cardiac output (CO) and blood pressure monitoring system could improve the safety of cardiac monitoring. The aim of the present study was to compare a noninvasive versus a standard invasive cardiovascular monitoring system. Methods: Nexfin HD is a continuous noninvasive blood pressure and cardiac output monitor system and is based on the development of the pulsatile unloading of the finger arterial walls using an inflatable finger cuff. During continuous BP measurement CO is calculated. We included 10 patients with standard invasive cardiac monitoring system (pulmonary artery catheter and arterial catheter) comparing invasively obtained data to the data collected noninvasively using the Nexfin HD. Results: Correlation between mean arterial pressure measured with the standard arterial monitoring system and the Nexfin HD was r2 = 0.67 with a bias of -2 mmHg and two standard deviations of ± 16 mmHg. Correlation between CO derived from PAC and the Nexfin HD was r2 = 0.83 with a bias of 0.23 l/min and two standard deviations of ± 2.1 l/min; the percentage error was 29%. Conclusion: Although the noninvasive CO measurement appears promising, the noninvasive blood pressure assessment is clearly less reliable than the invasively measured blood pressure. Therefore, according to the present data application of the Nexfin HD monitoring system in the ICU cannot be recommended generally. Whether such a tool might be reliable in certain critically ill patients remains to be determined

    Genealogies of Slavery

    Get PDF
    This chapter addresses the concept of slavery, exploring its character and significance as a dark page in history, but also as a specifically criminological and zemiological problem, in the context of international law and human rights. By tracing the ambiguities of slavery in international law and international development, the harms associated with slavery are considered. Harms include both those statutorily proscribed, and those that are not, but that can still be regarded as socially destructive. Traditionally, antislavery has been considered within the parameters of abolition and criminalization. In this context recently, anti-trafficking has emerged as a key issue in contemporary anti-slavery work. While valuable, anti-trafficking is shown to have significant limitations. It advances criminalization and stigmatization of the most vulnerable and further perpetuates harm. At the same time, it identifies structural conditions like poverty, vulnerability, and “unfreedom” of movement only to put them aside. Linked to exploitation, violence and zemia, the chapter brings to the fore some crucial questions concerning the prospects of systemic theory in the investigation of slavery, that highlight the root causes of slavery, primarily poverty and inequality. Therefore, the chapter counterposes an alternative approach in which the orienting target is not abolition of slavery but advancing structural changes against social harm
    corecore