58 research outputs found

    Comparison of static chambers to measure CH4 emissions from soils

    Get PDF
    The static chamber method (non-flow-through-non-steady-state chambers) is the most common method to measure fluxes of methane (CH4) from soils. Laboratory comparisons to quantify errors resulting from chamber design, operation and flux calculation methods are rare. We tested fifteen chambers against four flux levels (FL) ranging from 200 to 2300 g CH4m−2 h−1. The measurements were conducted on a calibration tank using three quartz sand types with soil porosities of 53% (dry fine sand, S1), 47% (dry coarse sand, S2), and 33% (wetted fine sand, S3). The chambers tested ranged from 0.06 to 1.8 m in height, and 0.02 to 0.195 m3 in volume, 7 of them were equipped with a fan, and 1 with a vent-tube. We applied linear and exponential flux calculation methods to the chamber data and compared these chamber fluxes to the reference fluxes from the calibration tank. The chambers underestimated the reference fluxes by on average 33% by the linear flux calculation method (Rlin), whereas the chamber fluxes calculated by the exponential flux calculation method (Rexp) did not significantly differ from the reference fluxes (p < 0.05). The flux under- or overestimations were chamber specific and independent of flux level. Increasing chamber height, area and volume significantly reduced the flux underestimation (p < 0.05). Also, the use of non-linear flux calculation method significantly improved the flux estimation; however, simultaneously the uncertainty in the fluxes was increased. We provide correction factors, which can be used to correct the under- or overestimation of the fluxes by the chambers in the experiment.Peer reviewe

    Time series of methane and carbon dioxide concentrations measured in subglacial air, Western Greenland

    No full text
    Time series of methane and carbon dioxide concentrations measured in subglacial air in a cave under the Isunnguate Sermia glacier, Western Greenland. The Isunnguata Sermia is a glacier fed by the Greenland Ice Sheet. The time series are of shorter duration, 1 to 7 hours, and cover a 4-day period from August 23rd - 26th 2016. In situ concentrations of methane and carbon dioxide of the subglacial air were measured using a portable greenhouse gas analyzer based on state-of-the-art cavity ring-down spectroscopy with a measurement precision of 3 ppb and 0.4 ppm for methane and carbon dioxide, respectively and a sampling frequency of 1 hz (GasScouter G4301, Picarro Inc., CA, USA). The analyzer was connected to a flux chamber via a PVC tube (4 meter)
    corecore