524 research outputs found

    Live User-guided Intrinsic Video For Static Scenes

    Get PDF
    We present a novel real-time approach for user-guided intrinsic decomposition of static scenes captured by an RGB-D sensor. In the first step, we acquire a three-dimensional representation of the scene using a dense volumetric reconstruction framework. The obtained reconstruction serves as a proxy to densely fuse reflectance estimates and to store user-provided constraints in three-dimensional space. User constraints, in the form of constant shading and reflectance strokes, can be placed directly on the real-world geometry using an intuitive touch-based interaction metaphor, or using interactive mouse strokes. Fusing the decomposition results and constraints in three-dimensional space allows for robust propagation of this information to novel views by re-projection.We leverage this information to improve on the decomposition quality of existing intrinsic video decomposition techniques by further constraining the ill-posed decomposition problem. In addition to improved decomposition quality, we show a variety of live augmented reality applications such as recoloring of objects, relighting of scenes and editing of material appearance

    Development of Combined Opto-Acoustical Sensor Modules

    Full text link
    The faint fluxes of cosmic neutrinos expected at very high energies require large instrumented detector volumes. The necessary volumes in combination with a sufficient shielding against background constitute forbidding and complex environments (e.g. the deep sea) as sites for neutrino telescopes. To withstand these environments and to assure the data quality, the sensors have to be reliable and their operation has to be as simple as possible. A compact sensor module design including all necessary components for data acquisition and module calibration would simplify the detector mechanics and ensures the long term operability of the detector. The compact design discussed here combines optical and acoustical sensors inside one module, therefore reducing electronics and additional external instruments for calibration purposes. In this design the acoustical sensor is primary used for acoustic positioning of the module. The module may also be used for acoustic particle detection and marine science if an appropriate acoustical sensor is chosen. First tests of this design are promising concerning the task of calibration. To expand the field of application also towards acoustic particle detection further improvements concerning electromagnetic shielding and adaptation of the single components are necessary.Comment: 4 pages, 2 figures, ARENA2010 proceeding

    Reconstruction methods for acoustic particle detection in the deep sea using clusters of hydrophones

    Full text link
    This article focuses on techniques for acoustic noise reduction, signal filters and source reconstruction. For noise reduction, bandpass filters and cross correlations are found to be efficient and fast ways to improve the signal to noise ratio and identify a possible neutrino-induced acoustic signal. The reconstruction of the position of an acoustic point source in the sea is performed by using small-volume clusters of hydrophones (about 1 cubic meter) for direction reconstruction by a beamforming algorithm. The directional information from a number of such clusters allows for position reconstruction. The algorithms for data filtering, direction and position reconstruction are explained and demonstrated using simulated data.Comment: 7 pages, 13 figure

    Operação cappuccino: os galegos, os cromos, os saldos, as vitaminas e os bacocos!...

    Get PDF
    Já vem sendo sina, de há uns anos a esta parte! É o que dá quando a palavra avião nos faz disparar a adrenalina! É o que dá fugir dele como o diabo da cruz!... É o que dá quando se recorre ao andante de quatro rodas... Nem sempre se vai para onde se deseja! Mas, entre ficar em casa e ir laurear a pevide, ou, simplesmente para o banho de cultura anual, mil vezes a segunda… Este ano voltámos a tripartir o périplo

    Crime e Castigo: "Pecados Públicos" e Disciplinamento Social na Diocese de Viseu (1684-1689)

    Get PDF
    Entre 1684 e 1689 o Tribunal Episcopal da diocese Viseu, cuja presidência cabia ao então bispo D. Ricardo Russel, sentenciou 122 réus, entre leigos e eclesiásticos, julgados maioritariamente por delitos de natureza moral e práticas sexuais consideradas ilícitas. Pretende-se com este estudo dar a conhecer o Auditório Eclesiástico - uma das instituições mais marcantes do poder episcopal pós-tridentino - perscrutando o seu modelo de funcionamento e de actuação, e aferindo qual o impacto que pode ter tido na vigilância e disciplinamento da população da diocese

    Position reconstruction of acoustic sources with the AMADEUS Detector

    Full text link
    This article focuses on techniques for position reconstruction of acoustic point sources with the AMADEUS setup consisting of 36 acoustic sensors in the Mediterranean Sea. The direction reconstruction of an acoustic point source utilizes the information of the 6 small-volume hydrophone clusters of AMADEUS individually. Source position reconstruction is then done by combining the directional information of each cluster. The algorithms for direction and position reconstruction are explained and demonstrated using data taken in the deep sea.Comment: 4 pages, 7 figures, to appear in the proceedings of the 3rd International Workshop on the Acoustic and Radio EeV Neutrino detection Activities, Rome, Ital

    Multi-vessel stenting during primary percutaneous coronary intervention for acute myocardial infarction. A single-center experience

    Get PDF
    BACKGROUND: Recanalization of the culprit lesion is the main goal of primary angioplasty for acute ST-segment elevation myocardial infarction (STEMI). Patients presenting with acute myocardial infarction and multivessel disease are, therefore, usually subjected to staged procedures, with the primary percutaneous coronary intervention (PCI) confined to recanalization of the infarct-related artery (IRA). Theoretically at least, early relief of stenoses of non-infarct-related arteries could promote collateral circulation, which could help to limit the infarct size. However, the safety and feasibility of such an approach has not been adequately established. METHODS: In this single-center prospective study we examined 73 consecutive patients who had an acute STEMI and at least one or more lesions > or = 70% in a major epicardial vessel other than the infarct-related artery. In the first 28 patients, forming the multi-vessel (MV) PCI group, all lesions were treated during the primary procedure. In the following 45 patients, forming the culprit-only (CO) PCI group, only the culprit lesion was treated during the initial procedure, followed by either planned-staged or ischemia-driven revascularization of the non-culprit lesions. Fluoroscopy time and contrast dye amount were compared between both groups, and patients were followed up for one year for major adverse cardiac events (MACE) and other significant clinical events. RESULTS: The two groups were well balanced in terms of clinical characteristics, number of diseased vessels and angiographic characteristics of the culprit lesion. In the MV-PCI group, 2.51 lesions per patient were treated using 2.96 +/- 1.34 stents (1.00 lesions and 1.76 +/- 1.17 stents in the CO-PCI group, both p < 0.001). The fluoroscopy time increased from 10.3 (7.2-16.9) min in the CO-PCI group to 12.5 (8.5-19.3) min in the MV-PCI group (p = 0.22), and the amount of contrast used from 200 (180-250) ml to 250 (200-300) ml, respectively (p = 0.16). Peak CK and CK-MB were significantly lower in patients of the MV-PCI group (843 +/- 845 and 135 +/- 125 vs 1652 +/- 1550 and 207 +/- 155 U/l, p < 0.001 and 0.01, respectively). Similar rates of major adverse cardiac events at one year were observed in the two groups (24% and 28% in multi-vessel and culprit treatment groups, p = 0.73). The incidence of new revascularization in both infarct- and non-infarct-related arteries was also similar (24% and 28%, respectively, p = 0.73). CONCLUSION: We may state from this limited experience that a multi-vessel stenting approach for patients with acute STEMI and multi-vessel disease is feasible and probably safe during routine clinical practice. Our data suggest that this approach may help to limit the infarct size. However, larger studies, perhaps using drug-eluting stents, are still needed to further evaluate the safety and efficiency of this procedure, and whether it is associated with a lower need of subsequent revascularization and lower costs

    Walker 256 tumor growth suppression by crotoxin involves formyl peptide receptors and lipoxin a(4)

    Get PDF
    We investigated the effects of Crotoxin (CTX), the main toxin of South American rattlesnake (Crotalus durissus terrificus) venom, on Walker 256 tumor growth, the pain symptoms associated (hyperalgesia and allodynia), and participation of endogenous lipoxin A(4). Treatment with CTX (s.c.), daily, for 5 days reduced tumor growth at the 5th day after injection of Walker 256 carcinoma cells into the plantar surface of adult rat hind paw. This observation was associated with inhibition of new blood vessel formation and decrease in blood vessel diameter. The treatment with CTX raised plasma concentrations of lipoxin A 4 and its natural analogue 15-epi-LXA(4) 4, an effect mediated by formyl peptide receptors (FPRs). In fact, the treatment with Boc-2, an inhibitor of FPRs, abolished the increase in plasma levels of these mediators triggered by CTX. The blockage of these receptors also abolished the inhibitory action of CTX on tumor growth and blood vessel formation and the decrease in blood vessel diameter. Together, the results herein presented demonstrate that CTX increases plasma concentrations of lipoxin A 4 and 15-epi-LXA 4, which might inhibit both tumor growth and formation of new vessels via FPRs.Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (fellowship-CAPES)PAP (fellowship-Secretaria da Saude do Estado de Sao Paulo)FAPESP [07/52447-8]Guggenheim FoundationSpecial Laboratory of Pain and Signaling, Butantan Institute, Avenida Vital Brazil 1500, 05503-900 São Paulo, SP, BrazilCEIS/Department of Biology, Institute of Biosciences of Rio Claro, São Paulo State University (UNESP), Rio Claro, SP, BrazilLaboratory of Pathophysiology, Butantan Institute, Avenida Vital Brazil 1500, 05503-900 São Paulo, SP, BrazilDepartment of Natural Sciences, Mathematics and Education, Agricultural Sciences Center, Federal University of São Carlos, Rodovia Anhanguera Km 174, 13600-970 Araras, SP, BrazilLaboratory of Inflammation and Vascular Pharmacology, Federal University of São Paulo, Rua São Nicolau 210, 09913-030 Diadema, SP, BrazilDepartment of Physiology and Biophysics, Institute of Biomedical Sciences, University of São Paulo, Avenida Professor Lineu Prestes 1524, 05508-900 São Paulo, SP, BrazilDepartment of Pharmacology, Institute of Biomedical Sciences, University of São Paulo, Avenida Professor Lineu Prestes 1524, 05508-900 São Paulo, SP, BrazilLaboratory of Inflammation and Vascular Pharmacology, Federal University of São Paulo, Rua São Nicolau 210, 09913-030 Diadema, SP, BrazilFAPESP: 07/52447-8Web of Scienc

    Science verification of the new FlashCam-based camera in the 28m telescope of H.E.S.S

    Get PDF
    In October 2019 the central 28m telescope of the H.E.S.S. experiment has beenupgraded with a new camera. The camera is based on the FlashCam design whichhas been developed in view of a possible future implementation in themedium-sized telescopes of the Cherenkov Telescope Array (CTA). We report hereon the results of the science verification program that has been performedafter commissioning of the new camera, to show that the camera and softwarepipelines are working up to expectations.<br
    • …
    corecore