18,263 research outputs found

    From car to bike. Marketing and dialogue as a driver of change

    Get PDF
    The Paris Climate Agreement has sent a key message to the international community regarding the need to increase efforts to move towards a low-carbon economy and help slow climate change, while underpinning global long-term economic growth and sustainable development. COP 21 recognizes the social, economic and environmental value of voluntary mitigation actions and their co-benefits for adaptation, health and sustainable development. In this framework, the PTP Cycle project, running from 2013 to 2016 and funded by the European Commission through the Intelligent Energy Europe program, introduces a non-market approach through voluntary participation in the adoption of sustainable transport modes such as cycling, based on marketing to potential customers through Personalized Travel Plans. The medium-sized city of Burgos (Spain) and the cities of Ljubljana, Riga, Antwerp and London (boroughs of Haringey and Greenwich) developed a new policy instrument (Personalized Travel Plans) in order to increase bike patronage. Beyond potential savings of CO2, the results show that PTP as a form of Active Mobility Consultancy is a suitable instrument to influence modal shift to public transport, walking and cycling, and to address the challenges of climate change, while fostering sustainable transportation by changing mobility behaviour. These results, matching with the state-of-the-art of studies and pilot applications in other countries, allows deriving differentiated results for medium-size and large urban areas

    Transient increases in intracellular calcium and reactive oxygen species levels in TCam-2 cells exposed to microgravity

    Get PDF
    The effects of microgravity on functions of the human body are well described, including alterations in the male and female reproductive systems. In the present study, TCam-2 cells, which are considered a good model of mitotically active male germ cells, were used to investigate intracellular signalling and cell metabolism during exposure to simulated microgravity, a condition that affects cell shape and cytoskeletal architecture. After a 24 hour exposure to simulated microgravity, TCam-2 cells showed 1) a decreased proliferation rate and a delay in cell cycle progression, 2) increased anaerobic metabolism accompanied by increased levels of intracellular Ca(2+), reactive oxygen species and superoxide anion and modifications in mitochondrial morphology. Interestingly, all these events were transient and were no longer evident after 48 hours of exposure. The presence of antioxidants prevented not only the effects described above but also the modifications in cytoskeletal architecture and the activation of the autophagy process induced by simulated microgravity. In conclusion, in the TCam-2 cell model, simulated microgravity activated the oxidative machinery, triggering transient macroscopic cell events, such as a reduction in the proliferation rate, changes in cytoskeleton-driven shape and autophagy activation

    Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

    Get PDF
    On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values

    Comment on ``Two Time Scales and Violation of the Fluctuation-Dissipation Theorem in a Finite Dimensional Model for Structural Glasses''

    Full text link
    In cond-mat/0002074 Ricci-Tersenghi et al. find two linear regimes in the fluctuation-dissipation relation between density-density correlations and associated responses of the Frustrated Ising Lattice Gas. Here we show that this result does not seem to correspond to the equilibrium quantities of the model, by measuring the overlap distribution P(q) of the density and comparing the FDR expected on the ground of the P(q) with the one measured in the off-equilibrium experiments.Comment: RevTeX, 1 page, 2 eps figures, Comment on F. Ricci-Tersenghi et al., Phys. Rev. Lett. 84, 4473 (2000

    Stellar archeology of the nearby LINER galaxies NGC 4579 and NGC 4736

    Full text link
    Stellar archeology of nearby LINER galaxies may reveal if there is a stellar young population that may be responsible for the LINER phenomenon. We show results for the classical LINER galaxies NGC 4579 and NGC 4736 and find no evidence of such populations.Comment: 2 pages, 2 figures, to be published in the Proceedings of the IAU Symposium no. 26

    Laparoscopic totally extraperitoneal inguinal hernia repair in the elderly: A prospective control study

    Get PDF
    Inguinal hernia (IH) repair can be obtained with both open and laparoscopic techniques, which are usually performed using a transabdominal preperitoneal (TAPP) or a totally extraperitoneal (TEP) approach. The aim of the study was to evaluate whether the results of laparoscopic TEP IH repair in the elderly ( 6565 years old) are different with respect to results obtained in younger patients. One hundred and four consecutive patients (four women and 100 men, median age of 57 years, range=21-85 years) with unilateral (N=21, 20.2%) or bilateral (N=83, 79.8%) IH were prospectively enrolled in the study. Patients were divided into two groups according to their age: group A (N=68, 65.4%) aged <65 years and group B (N=36, 34.6%) aged 6565 years. The mean operative time was not significantly different between groups (48\ub120 vs. 52\ub120 min, p=0.33). One case of increased PaCO2 was observed in each group (p=0.72) and two and one case of pneumoperitoneum (p=0.57) in groups A and B, respectively. Two (1.9%) patients (one in each group; p=0.55) required TEP conversion. Mild postoperative complications developed in four patients of each group (p=0.44). After one-year follow-up, three (2.9%) recurrences occurred (group 1=1, group 2=2, p=0.55), both in patients who had undergone direct IH repair. The overall postoperative relative risk of complications related to age was 1.08 (95% confidence interval=0.91-1.27, p=0.53). In conclusion, our results suggest that in patients with IH scheduled for TEP repair, age does not represent a contraindication to surgery in terms of complication rate and postoperative results

    ALMA observations of the debris disk around the young Solar Analog HD 107146

    Get PDF
    We present ALMA continuum observations at a wavelength of 1.25 mm of the debris disk surrounding the ∼\sim 100 Myr old solar analog HD 107146. The continuum emission extends from about 30 to 150 AU from the central star with a decrease in the surface brightness at intermediate radii. We analyze the ALMA interferometric visibilities using debris disk models with radial profiles for the dust surface density parametrized as i) a single power-law, ii) a single power-law with a gap, and iii) a double power-law. We find that models with a gap of radial width ∼8\sim 8 AU at a distance of ∼80\sim 80 AU from the central star, as well as double power-law models with a dip in the dust surface density at ∼70\sim 70 AU provide significantly better fits to the ALMA data than single power-law models. We discuss possible scenarios for the origin of the HD 107146 debris disk using models of planetesimal belts in which the formation of Pluto-sized objects trigger disruptive collisions of large bodies, as well as models which consider the interaction of a planetary system with a planetesimal belt and spatial variation of the dust opacity across the disk. If future observations with higher angular resolution and sensitivity confirm the fully-depleted gap structure discussed here, a planet with a mass of approximately a few Earth masses in a nearly circular orbit at ∼80\sim 80 AU from the central star would be a possible explanation for the presence of the gap.Comment: (38 pages, 7 figures, accepted for publication in ApJ

    What information could the main actors of liquid biopsy provide? A representative case of non-small cell lung cancer (NSCLC)

    Get PDF
    In non-small cell lung cancer (NSCLC), there is a consensus regarding the use of liquid biopsy, generally, to detect "druggable" mutations and, in particular, to monitor tyrosine kinase inhibitor (TKI) treatments. However, whether circulating tumor cells (CTCs) are better tools than cell-free DNA (cfDNA), is still a matter of debate, mainly concerning which antigen(s) we should use to investigating simultaneously both epithelial and epithelial-to-mesenchymal transient (EMT) phenotype in the same sample of CTCs. To address this item, we exploited here a single-tube liquid biopsy, to detect both epithelial cell adhesion molecule (EpCAM)-positive CTCs and EpCAM-low/negative CTCs, because down-modulation of EpCAM is considered the first step in EMT. Furthermore, we analyzed the DNA from CTCs of four different phenotypes (ctcDNA), according to their EpCAM expression and cytokeratin pattern, and circulating tumor DNA (ctDNA) by droplet digital PCR (ddPCR), in order to disclose activating and resistancedriving mutations. Liquid biopsy reflected spatial and temporal heterogeneity of the tumor under treatment pressure. We provide the proof-of-concept that the complementary use of ctDNA and ctcDNA represents a reliable, minimally invasive and dynamic tool for a more comprehensive view of tumor evolution

    Mapping low and high density clouds in astrophysical nebulae by imaging forbidden line emission

    Full text link
    Emission line ratios have been essential for determining physical parameters such as gas temperature and density in astrophysical gaseous nebulae. With the advent of panoramic spectroscopic devices, images of regions with emission lines related to these physical parameters can, in principle, also be produced. We show that, with observations from modern instruments, it is possible to transform images taken from density sensitive forbidden lines into images of emission from high and low-density clouds by applying a transformation matrix. In order to achieve this, images of the pairs of density sensitive lines as well as the adjacent continuum have to be observed and combined. We have computed the critical densities for a series of pairs of lines in the infrared, optical, ultraviolet and X-rays bands, and calculated the pair line intensity ratios in the high and low-density limit using a 4 and 5 level atom approximation. In order to illustrate the method we applied it to GMOS-IFU data of two galactic nuclei. We conclude that this method provides new information of astrophysical interest, especially for mapping low and high-density clouds; for this reason we call it "the ld/hd imaging method".Comment: 7 pages, 4 figures, accepted for publication on MNRA

    Reducing the linewidth of a diode laser below 30 Hz by stabilization to a reference cavity with finesse above 10^5

    Get PDF
    An extended cavity diode laser operating in the Littrow configuration emitting near 657 nm is stabilized via its injection current to a reference cavity with a finesse of more than 10^5 and a corresponding resonance linewidth of 14 kHz. The laser linewidth is reduced from a few MHz to a value below 30 Hz. The compact and robust setup appears ideal for a portable optical frequency standard using the Calcium intercombination line.Comment: 8 pages, 4 figures on 3 additional pages, corrected version, submitted to Optics Letter
    • …
    corecore