92 research outputs found

    Antimicrobial Effect and Surface Tension of Some Chelating Solutions with Added Surfactants

    Get PDF
    Abstract This study assessed the antimicrobial efficacy and surface tension of established irrigating solutions with a new experimental chelating solution in infected dentin tubes. Twenty-five specimens were randomly assigned to each of the irrigating solutions. Twenty specimens were used as negative and positive controls. After 21 days of contamination with E. faecalis, the irrigating solutions MTAD, QMiX and Tetraclean NA were delivered into each infected root canal. The solutions were removed and dentin samples were withdrawn from the root canals with sterile low-speed round burs with increasing ISO diameters. The dentin powder samples obtained with each bur were immediately collected in separate test tubes containing 3 mL of BHI broth. After that, 100 ÎĽL from each test tube was cultured on blood agar. The grown colonies were counted and recorded as colony-forming units (CFU). The surface tension of the irrigants was measured using a Cahn DCA-322 Dynamic Contact Angle Analyzer. A Kruskal Wallis nonparametric ANOVA and a Friedman test were used (p<0.05). Tetraclean NA showed lower surface tension and CFU values than MTAD and QMiX. Better antibacterial action and low surface tension were observed for Tetraclean NA, probably due to the improved penetration into the root canal and dentinal tube

    Modal analysis of semi-enclosed basins

    Get PDF
    Abstract This paper presents a novel technique for the computation of eigenvalues and eigenvectors of partially enclosed basins such as harbours and bays. The procedure makes use of the finite element approximation of the linear shallow water equations, and converts the time-depending problem into an eigenvalues one. The main point of novelty of this research is the mathematical condition used at the boundary that separates the computational domain from the open sea. While classical techniques impose a zero surface elevation (i.e. a nodal line), here an approximate radiation condition is applied. The use of a radiation condition at the open boundary gives a quadratic eigenvalue problem that admits as solution complex eigenvalues and eigenvectors, thus describing the flow in terms of both standing and progressive waves. The new method is applied to an idealized long and narrow harbour, for which an analytical solution of long wave resonance exists, and to the harbour of Marina di Carrara (Italy), for which measurements and previous numerical computation results are available. In both cases the results show good agreement with the available data

    Shear bond strength of one-step self-etch adhesives to dentin : evaluation of NaOCl pretreatment

    Get PDF
    The aim of this study was to evaluate the influence of dentin pretreatment with NaOCl on shear bond strength of four one-step self-etch adhesives with different pH values. Bovine permanent incisors were used. Four one-step self-etch adhesives were tested: Adper? Easy Bond, Futurabond NR, G-aenial Bond, Clearfil S3 Bond. One two-step self-etch adhesive (Clearfil SE Bond) was used as control. Group 1- no pretreatment; group 2- pretratment with 5,25 % NaOCl; group 3- pretreatment with 37 % H3PO4 etching and 5,25 % NaOCl. A hybrid composite resin was inserted into the dentin surface. The specimens were tested in a universal testing machine. The examiners evaluated the fractured surfaces in optical microscope to determine failure modes, quantified with adhesive remnant index (ARI). Dentin pretreatment variably influenced bond strength values of the different adhesive systems. When no dentin pretreatment was applied, no significant differences were found (P >.05) among four adhesives tested. No significant differences were recorded when comparing NaOCl pretreatment with H3PO4 + NaOCl pretreatment for all adhesive tested (P >.05) except Clearfil S3 Bond that showed higher shear bond strength values when H3PO4 was applied. Frequencies of ARI scores were calculated. The influence of dentin pretreatment with NaOCl depends on the composition of each adhesive system used. There was no difference in bond strength values among self-etch adhesives with different pH values

    In vitro antibacterial activity of different pulp capping materials

    Get PDF
    Background: Direct pulp capping involves the application of a dental material to seal communications between the exposed pulp and the oral cavity (mechanical and carious pulp exposures) in an attempt to act as a barrier, protect the dental pulp complex and preserve its vitality. The aim of this study was to evaluate and compare, by the agar disc diffusion test, the antimicrobial activity of six different pulp-capping materials: Dycal (Dentsply), Calcicur (Voco), Calcimol LC (Voco), TheraCal LC (Bisco), MTA Angelus (Angelus), Biodentine (Septodont). Material and Methods: Streptococcus salivarius , Streptococcus sanguis and Streptococcus mutans strains were selected to evaluate the antimicrobial activity by the agar disc diffusion test of different pulp capping materials. Paper disks were impregnated whit each pulp capping materials and placed onto culture agar-plates pre-adsorbed with bacterial cells and further incubated for 24 h at 37°C. The growth inhibition zones around each pulp capping materials were recorded and compared for each bacterial strain. Results: For the investigation of the antibacterial properties the ANOVA showed the presence of significant differences among the various materials. Tukey test showed that MTA-based materials induced lower growth inhibition zones. Conclusions: MTA-based products show a discrete antibacterial activity varying from calcium hydroxide-based materials which present an higher antibacterial activity

    Fluoride release and uptake abilities of different fissure sealants

    Get PDF
    Background: The long-term capability of resin sealants and glass ionomer cements to release fluoride is associated to a reduction in pit and fissure caries. The regular use of fluoride varnishes/toothpastes can result in the absorption of fluoride into the sealant. The objective of the present study was to assess the fluoride release/uptake capacities of different fissure sealants. Material and Methods: Three different fissure sealants (Fuji Triage/GC, Fissurit FX/Voco and Grandio Seal/Voco) were examined. Ten discs of each material were prepared. Each disc was incubated with distilled water and then the solution analyzed for diluted for fluoride concentration, using a combination of fluoride electrode (OrionGP 1 S/N 13824, Orion Research Inc, Boston, MA, USA) connected to an expandable ion analyzer (Orion 720A, Orion Research Inc, Boston, MA, USA). Standard curves between 1 and 100 ppm F- were used to calibrate the electrode. Cumulative fluoride release was measured on days 1, 2, 3, 5, 7, 21, 35 and 49, then two different fluoride varnishes/ pastes (Profluorid Varnish/Voco, MI Paste Plus/GC), were applied to the sealants tested, and fluoride release (after reuptake) was measured on days 56, 70 and 84. Results: Kruskal Wallis test confirmed significant differences in fluoride release between Fuji Triage/GC and Fissurit FX/Voco and Grandio Seal/Voco from day 1 ( P < 0.001). The application of fluoride varnish Profluorid Varnish enhanced the fluoride release for all sealants ( P < 0.05). MI Paste Plus enhanced the fluoride release for all sealants except for Fuji Triage/GC ( P > 0.05). Conclusions: The GIC-based sealant (Fuji Triage/GC) released significantly more fluoride than the resin sealants tested. The exposure to the fluoridated varnish (Profluorid Varnish) significantly recharged the sealants tested more than the CPP-ACPF toothpaste (MI Paste Plus)

    Remineralizing effect of a zinc-hydroxyapatite toothpaste on enamel erosion caused by soft drinks : ultrastructural analysis

    Get PDF
    The aim of the present in vitro study was to evaluate the protective effects of a zinc-hydroxyapatite toothpaste on repairing enamel erosion produced by a soft drink (Coca-Cola) compared to toothpastes with and without fluoride using Scanning Electron Microscopy (SEM). Fifty specimens were assigned to 5 groups of 10 specimens each. (Group 1: no erosive challenge, no toothpaste treatment, group 2: erosive challenge, no toothpaste treatment, 3: erosive challenge, toothpaste without fluoride, group 4: erosive challenge, fluoride toothpaste treatment, group 5: erosive challenge, zinc-hydroxyapatite toothpaste treatment). Repeated erosive challenges were provided by immersing bovine enamel specimens (10 per group) in a soft drink for 2 min (6mL, room temperature) at 0, 8, 24 and 32 h. After each erosive challenge, the toothpastes were applied neat onto the surface of specimens for 3 min without brushing and removed with distilled water. Between treatments the specimens were kept in artificial saliva. The surface of each specimen was imaged by SEM. Statistically significant differences were found between the samples used as control and those immersed in Coca-Cola (group 1 and 2): indeed among all groups the highest grade of damage was found in group 2. Instead the lowest grade was recorded in the samples of group 5 (Zinc hydroxyapatite toothpaste). The results of this study confirmed the potential benefit the Zn-HAP technology could provide in protecting enamel from erosive acid challenges. The treatment of erosively challenged enamel with Zn-Hap toothpaste showed a clear protective effect

    Influence of Temperature on the Antibacterial Activity of Sodium Hypochlorite

    Get PDF
    The aim of this study was to compare the antimicrobial activity of 5.25% NaOCl, Hypoclean and Chlor-Xtra at 20 °C and 45 °C in bovine root dentin. One-hundred-and-seventy dentin tubes prepared from bovine maxillary incisors were infected for 21 days with Enterococcus faecalis. The specimens were divided into the following groups: 1. 5.25% NaOCl 20 °C; 2. Hypoclean 20 °C; 3. Chlor-Xtra 20 °C; 4. 5.25% % NaOCl 45 °C; 5. Hypoclean 45 °C; 6. Chlor-Xtra 45 °C; 7. positive control; 8. negative control. Dentin chips were collected with round burs into Brain Heart Infusion (BHI) broth. After culturing, the number of colony- forming units (CFU) was counted. Statistical analyses were performed using descriptive statistics (mean, standard deviation, median), Shapiro-Wilk test, ANOVA and Tukey test. Significance level was set at p<0.05. In all experimental groups, CFU was minimum after treatment (day 0) and the obtained results were significantly different from each other at any period (p<0.05). After treatment, the Hypoclean and Chlor-Xtra showed the lowest numbers of CFU at 20 °C and 45 °C, whereas 5.25% NaOCl showed the highest number of CFU at both temperatures. In each group, the number of CFUs increased significantly with time (p<0.05). The antibacterial activity of Hypoclean and Chlor-Xtra at 45 °C were significantly greater than other tested solutions

    Differences between panoramic and Cone Beam-CT in the surgical evaluation of lower third molars

    Get PDF
    The aim of this study was to evaluate the ability to identify the contiguity between the root of the mandibular third molar and the mandibular canal (MC) in panoramic radiographs compared with Cone Beam-CT. Panoramic radiographs of 326 third molars and CBCT radiographs of 86 cases indicated for surgery and considered at risk were evaluated. The following signs were assessed in panoramic radiographs as risk factors: radiolucent band, loss of MC border, change in MC direction, MC narrowing, root narrowing, root deviation, bifid apex, superimposition, and contact between the root third molar and the MC. Radiographic signs associated with absence of MC cortical bone are: radiolucent band, loss of MC border, change in MC direction, and superimposition. The number of risk factors was significantly increased with an increasing depth of inclusion. CBCT revealed a significant association between the absence of MC cortical bone and a lingual or interradicular position of the MC. In cases in which panoramic radiographs do not exclude contiguity between the MC and tooth, careful assessment the signs and risks on CBCT radiographs is indicated for proper identification of the relationships between anatomic structures

    Effect of glycine pretreatment on the shear bond strength of a CAD/CAM resin nano ceramic material to dentin

    Get PDF
    Background: The purpose of this study was to evaluate the effect of glycine pretreatment on the shear bond strength between dentin and a CAD/CAM resin nano ceramic material (LavaTM Ultimate Restorative), bonded together with adhesive cements using three different luting protocols (total-etch; self-etch; self-adhesive). Material and Methods: Thirty cylinders were milled from resin nano ceramic blocks with CAD/CAM technology. The cylinders were subsequently cemented to the exposed dentin of 30 bovine permanent mandibular incisors. The specimens were assigned into six groups of five teeth each according to luting procedure and dentin pretreatment. In the first two groups (A1, A2) 10 cylinders were cemented using a total-etch protocol; in groups B1 and B2, 10 cylinders were cemented using a self-etch protocol; in groups C1 and C2, 10 cylinders were cemented using a self-adhesive protocol; in groups A1, B1 and C1 the dentinal surface was also treated with glycine powder. All cemented specimens were submitted to a shear bond strength test. Statistical analysis was performed with Stata 9.0 software. Results: ANOVA showed the presence of significant differences among the various groups ( P <0.0001). Conclusions: Glycine did not change the different bond strength demonstrated by the various luting protocols tested. Conventional resin composite cements used together with a self-etch adhesive reported the highest values. However the use of glycine seems to increase the bond strength of self-adhesive resin cements
    • …
    corecore