40 research outputs found

    Evaluation of detailed aromatic mechanisms (MCMv3 and MCMv3.1) against environmental chamber data

    Get PDF
    International audienceA high quality dataset on the photo-oxidation of benzene, toluene, p-xylene and 1,3,5-trimethylbenzene has been obtained from experiments in the European Photoreactor (EUPHORE), a large outdoor environmental reaction chamber. The experiments were designed to test sensitive features of detailed aromatic mechanisms, and the dataset has been used to evaluate the performance of the Master Chemical Mechanism Version 3 (MCMv3). An updated version (MCMv3.1) was constructed based on recent experimental data, and details of its development are described in a companion paper. The MCMv3.1 aromatic mechanisms have also been evaluated using the EUPHORE dataset. Significant deficiencies have been identified in the mechanisms, in particular: 1) an over-estimation of the ozone concentration, 2) an under-estimation of the NO oxidation rate, 3) an under-estimation of OH. The use of MCMv3.1 improves the model-measurement agreement in some areas but significant discrepancies remain

    Measurements of photo-oxidation products from the reaction of a series of alkyl-benzenes with hydroxyl radicals during EXACT using comprehensive gas chromatography

    Get PDF
    Photo-oxidation products from the reaction of a series of alkyl-benzenes, (benzene, toluene, <i>p</i>-xylene and 1,3,5-trimethyl-benzene) with hydroxyl radicals in the presence of NO<sub>x</sub> have been investigated using comprehensive gas chromatography (GCxGC). A GCxGC system has been developed which utilises valve modulation and independent separations as a function of both volatility and polarity. A number of carbonyl-type compounds were identified during a series of reactions carried out at the European Photoreactor (EUPHORE), a large volume outdoor reaction chamber in Valencia, Spain. Experiments were carried as part of the EXACT project (<b>E</b>ffects of the o<b>X</b>idation of <b>A</b>romatic <b>C</b>ompounds in the <b>T</b>roposphere). Two litre chamber air samples were cryo-focused, with a sampling frequency of 30 minutes, allowing the evolution of species to be followed over oxidation periods of 3-6 hours. To facilitate product identification, several carbonyl compounds, which were possible products of the photo-oxidation, were synthesised and used as reference standards.<br> <br> For toluene reactions, observed oxygenated intermediates found included the co-eluting pair <font face='Symbol'>a</font>-angelicalactone/4-oxo-2-pentenal, maleic anhydride, citraconic anhydride, benzaldehyde and <i>p</i>-methyl benzoquinone. In the <i>p</i>-xylene experiment, the products identified were E/Z-hex-3-en-2,5-dione and citraconic anhydride. For 1,3,5-TMB reactions, the products identified were 3,5-dimethylbenzaldehyde, 3,5-dimethyl-3H-furan-2-one and 3-methyl-5-methylene-5H-furan-2-one. Preliminary quantification was carried out on identified compounds using liquid standards. Comparison of FTIR and GCxGC for the measurement of the parent aromatics generally showed good agreement. Comparison of the concentrations observed by GCxGC to concentration-time profiles simulated using the Master Chemical Mechanism, MCMv3, demonstrates that this mechanism significantly over-predicts the concentrations of many product compounds and highlights the uncertainties which exist in our understanding of the atmospheric oxidation of aromatics

    Linezolid for infective endocarditis. A structured approach based on a national database experience

    Get PDF
    Current data on the frequency and efficacy of linezolid (LNZ) in infective endocarditis (IE) are based on small retrospective series. We used a national database to evaluate the effectiveness of LNZ in IE. This is a retrospective study of IE patients in the Spanish GAMES database who received LNZ. We defined 3 levels of therapeutic impact: LNZ 50% of the total treatment, and > 50% of the LNZ doses prescribed in the first weeks of treatment), and LNZ ? 7 days not fulfilling the high-impact criteria (LNZ-NHI). Effectiveness of LNZ was assessed using propensity score matching and multivariate analysis of high-impact cases in comparison to patients not treated with LNZ from the GAMES database matched for age-adjusted comorbidity Charlson index, heart failure, renal failure, prosthetic and intracardiac IE device, left-sided IE, and Staphylococcus aureus. Primary outcomes were in-hospital mortality and one-year mortality. Secondary outcomes included IE complications and relapses

    Role of age and comorbidities in mortality of patients with infective endocarditis

    Get PDF
    Purpose: The aim of this study was to analyse the characteristics of patients with IE in three groups of age and to assess the ability of age and the Charlson Comorbidity Index (CCI) to predict mortality. Methods: Prospective cohort study of all patients with IE included in the GAMES Spanish database between 2008 and 2015. Patients were stratified into three age groups:<65 years, 65 to 80 years, and = 80 years.The area under the receiver-operating characteristic (AUROC) curve was calculated to quantify the diagnostic accuracy of the CCI to predict mortality risk. Results: A total of 3120 patients with IE (1327 < 65 years;1291 65-80 years;502 = 80 years) were enrolled.Fever and heart failure were the most common presentations of IE, with no differences among age groups.Patients =80 years who underwent surgery were significantly lower compared with other age groups (14.3%, 65 years; 20.5%, 65-79 years; 31.3%, =80 years). In-hospital mortality was lower in the <65-year group (20.3%, <65 years;30.1%, 65-79 years;34.7%, =80 years;p < 0.001) as well as 1-year mortality (3.2%, <65 years; 5.5%, 65-80 years;7.6%, =80 years; p = 0.003).Independent predictors of mortality were age = 80 years (hazard ratio [HR]:2.78;95% confidence interval [CI]:2.32–3.34), CCI = 3 (HR:1.62; 95% CI:1.39–1.88), and non-performed surgery (HR:1.64;95% CI:11.16–1.58).When the three age groups were compared, the AUROC curve for CCI was significantly larger for patients aged <65 years(p < 0.001) for both in-hospital and 1-year mortality. Conclusion: There were no differences in the clinical presentation of IE between the groups. Age = 80 years, high comorbidity (measured by CCI), and non-performance of surgery were independent predictors of mortality in patients with IE.CCI could help to identify those patients with IE and surgical indication who present a lower risk of in-hospital and 1-year mortality after surgery, especially in the <65-year group

    Validation of the calibration of a laser-induced fluorescence instrument for the measurement of OH radicals in the atmosphere

    Get PDF
    An assessment of the accuracy of OH concentrations measured in a smog chamber by a calibrated laser-induced fluorescence (LIF) instrument has been made, in the course of 9 experiments performed to study the photo-oxidation of benzene, toluene, 1,3,5-trimethylbenzene, para-xylene, ortho-cresol and ethene at the European Photoreactor facility (EUPHORE). The LIF system was calibrated via the water photolysis / ozone actinometry approach. OH concentrations were inferred from the instantaneous rate of removal of each hydrocarbon species (measured by FTIR or HPLC) via the appropriate rate coefficient for their reaction with OH, and compared with those obtained from the LIF system. Good agreement between the two approaches was found for all species with the exception of 1,3,5-trimethylbenzene, for which OH concentrations inferred from hydrocarbon removal were a factor of 3 lower than those measured by the LIF system. From the remaining 8 experiments, an overall value of 1.15&plusmn;0.13 (&plusmn;1&sigma;) was obtained for [OH]LIF / [OH]Hydrocarbon Decay, compared with the estimated uncertainty in the accuracy of the water photolysis / ozone actinometry OH calibration technique of 26% (1&sigma;)

    Adaptive fuzzy control for inter-vehicle gap keeping

    No full text
    corecore