102 research outputs found

    Multiplex enzyme activity imaging by MALDI-IMS of substrate library conversions

    Get PDF
    Enzymes are fundamental to biological processes and involved in most pathologies. Here we demonstrate the concept of simultaneously mapping multiple enzyme activities (EA) by applying enzyme substrate libraries to tissue sections and analyzing their conversion by matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS). To that end, we spray-applied a solution of 20 naturally derived peptides that are known substrates for proteases, kinases, and phosphatases to zinc-fixed paraffin tissue sections of mouse kidneys. After enzyme conversion for 5 to 120 min at 37 °C and matrix application, the tissue sections were imaged by MALDI-IMS. We could image incubation time-dependently 16 of the applied substrates with differing signal intensities and 12 masses of expected products. Utilizing inherent enzyme amplification, EA-IMS can become a powerful tool to locally study multiple, potentially even lowly expressed, enzyme activities, networks, and their pharmaceutical modulation. Differences in the substrate detectability highlight the need for future optimizations

    rapmad: Robust analysis of peptide microarray data

    Get PDF
    Background: Peptide microarrays offer an enormous potential as a screening tool for peptidomics experiments and have recently seen an increased field of application ranging from immunological studies to systems biology. By allowing the parallel analysis of thousands of peptides in a single run they are suitable for high-throughput settings. Since data characteristics of peptide microarrays differ from DNA oligonucleotide microarrays, computational methods need to be tailored to these specifications to allow a robust and automated data analysis. While follow-up experiments can ensure the specificity of results, sensitivity cannot be recovered in later steps. Providing sensitivity is thus a primary goal of data analysis procedures. To this end we created rapmad (Robust Alignment of Peptide MicroArray Data), a novel computational tool implemented in R. Results: We evaluated rapmad in antibody reactivity experiments for several thousand peptide spots and compared it to two existing algorithms for the analysis of peptide microarrays. rapmad displays competitive and superior behavior to existing software solutions. Particularly, it shows substantially improved sensitivity for low intensity settings without sacrificing specificity. It thereby contributes to increasing the effectiveness of high throughput screening experiments. Conclusions: rapmad allows the robust and sensitive, automated analysis of high-throughput peptide array data. The rapmad R-package as well as the data sets are available from http://www.tron-mz.de/compmed

    Induced photon correlations through the overlap of two four-wave mixing processes in integrated cavities

    Get PDF
    Induced photon correlations are directly demonstrated by exploring two coupled nonlinear processes in an integrated device. Using orthogonally polarized modes within an integrated microring cavity, phase matching of two different nonlinear four-wave mixing processes is achieved simultaneously, wherein both processes share one target frequency mode, while their other frequency modes differ. The overlap of these modes leads to the coupling of both nonlinear processes, producing photon correlations. The nature of this process is confirmed by means of time- and power-dependent photon correlation measurements. These findings are relevant to the fundamental understanding of spontaneous parametric effects as well as single-photon-induced processes, and their effect on optical quantum state generation and control

    Identification of novel antiacetylated vimentin antibodies in patients with early inflammatory arthritis

    Get PDF
    OBJECTIVE: To investigate serum antibody reactivity against a panel of post-translationally modified vimentin peptides (PTMPs) in patients with early inflammatory arthritis. METHODS: A panel of PTMPs was developed. Microtitre plates were coated with peptides derived from vimentin that were identical in length and composition except at one amino acid that was changed to introduce one of three post-translational modifications (PTMs)—either a citrullinated, carbamylated or acetylated residue. Sera of 268 treatment-naive patients with early inflammatory arthritis and symptoms ≤3 months' duration were tested. Patients were assigned to one of three outcome categories at 18-month follow-up (rheumatoid arthritis (RA), persistent non-RA arthritis and resolving arthritis). RESULTS: Antibodies against citrullinated, carbamylated and acetylated vimentin peptides were detected in the sera of patients with early inflammatory arthritis. The proportion of patients seropositive for all antibody types was significantly higher in the RA group than in the other groups. Anti cyclic citrullinated peptide (CCP)-positive patients with RA had higher numbers of peptides recognised and higher levels of antibodies against those peptides, representing a distinct profile compared with the other groups. CONCLUSIONS: We show for the first time that antibodies against acetylated vimentin are present in the sera of patients with early RA and confirm and extend previous observations regarding anticitrullinated and anticarbamylated antibodies

    Primary ChAdOx1 vaccination does not reactivate pre-existing, cross-reactive immunity

    Get PDF
    Currently available COVID-19 vaccines include inactivated virus, live attenuated virus, mRNA-based, viral vectored and adjuvanted protein-subunit-based vaccines. All of them contain the spike glycoprotein as the main immunogen and result in reduced disease severity upon SARS-CoV-2 infection. While we and others have shown that mRNA-based vaccination reactivates pre-existing, cross-reactive immunity, the effect of vector vaccines in this regard is unknown. Here, we studied cellular and humoral responses in heterologous adenovirus-vector-based ChAdOx1 nCOV-19 (AZ; Vaxzeria, AstraZeneca) and mRNA-based BNT162b2 (BNT; Comirnaty, BioNTech/Pfizer) vaccination and compared it to a homologous BNT vaccination regimen. AZ primary vaccination did not lead to measurable reactivation of cross-reactive cellular and humoral immunity compared to BNT primary vaccination. Moreover, humoral immunity induced by primary vaccination with AZ displayed differences in linear spike peptide epitope coverage and a lack of anti-S2 IgG antibodies. Contrary to primary AZ vaccination, secondary vaccination with BNT reactivated pre-existing, cross-reactive immunity, comparable to homologous primary and secondary mRNA vaccination. While induced anti-S1 IgG antibody titers were higher after heterologous vaccination, induced CD4(+) T cell responses were highest in homologous vaccinated. However, the overall TCR repertoire breadth was comparable between heterologous AZ-BNT-vaccinated and homologous BNT-BNT-vaccinated individuals, matching TCR repertoire breadths after SARS-CoV-2 infection, too. The reasons why AZ and BNT primary vaccination elicits different immune response patterns to essentially the same antigen, and the associated benefits and risks, need further investigation to inform vaccine and vaccination schedule development

    Building ProteomeTools based on a complete synthetic human proteome.

    Get PDF
    We describe ProteomeTools, a project building molecular and digital tools from the human proteome to facilitate biomedical research. Here we report the generation and multimodal liquid chromatography-tandem mass spectrometry analysis of \u3e330,000 synthetic tryptic peptides representing essentially all canonical human gene products, and we exemplify the utility of these data in several applications. The resource (available at http://www.proteometools.org) will be extended to \u3e1 million peptides, and all data will be shared with the community via ProteomicsDB and ProteomeXchange

    Barriers and opportunities for implementation of a brief psychological intervention for post-ICU mental distress in the primary care setting – results from a qualitative sub-study of the PICTURE trial

    Get PDF

    Belle II Pixel Detector Commissioning and Operational Experience

    Get PDF
    corecore