708 research outputs found
Relationship between bank vole abundance, seroprevalence and human hantavirus infections
Reil, D., Imholt, C., Schmidt, S., Rosenfeld, U.M., Ulrich, R.G., Eccard, J.A., Jacob, J
ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument
The Dark Energy Spectroscopic Instrument (DESI) is under construction to
measure the expansion history of the universe using the baryon acoustic
oscillations technique. The spectra of 35 million galaxies and quasars over
14,000 square degrees will be measured during a 5-year survey. A new prime
focus corrector for the Mayall telescope at Kitt Peak National Observatory will
deliver light to 5,000 individually targeted fiber-fed robotic positioners. The
fibers in turn feed ten broadband multi-object spectrographs. We describe the
ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall
telescope from August 14 to September 30, 2016. ProtoDESI was an on-sky
technology demonstration with the goal to reduce technical risks associated
with aligning optical fibers with targets using robotic fiber positioners and
maintaining the stability required to operate DESI. The ProtoDESI prime focus
instrument, consisting of three fiber positioners, illuminated fiducials, and a
guide camera, was installed behind the existing Mosaic corrector on the Mayall
telescope. A Fiber View Camera was mounted in the Cassegrain cage of the
telescope and provided feedback metrology for positioning the fibers. ProtoDESI
also provided a platform for early integration of hardware with the DESI
Instrument Control System that controls the subsystems, provides communication
with the Telescope Control System, and collects instrument telemetry data.
Lacking a spectrograph, ProtoDESI monitored the output of the fibers using a
Fiber Photometry Camera mounted on the prime focus instrument. ProtoDESI was
successful in acquiring targets with the robotically positioned fibers and
demonstrated that the DESI guiding requirements can be met.Comment: Accepted versio
Observations of Microwave Continuum Emission from Air Shower Plasmas
We investigate a possible new technique for microwave measurements of
ultra-high energy cosmic ray (UHECR) extensive air showers which relies on
detection of expected continuum radiation in the microwave range, caused by
free-electron collisions with neutrals in the tenuous plasma left after the
passage of the shower. We performed an initial experiment at the AWA (Argonne
Wakefield Accelerator) laboratory in 2003 and measured broadband microwave
emission from air ionized via high energy electrons and photons. A follow-up
experiment at SLAC (Stanford Linear Accelerator Center) in summer of 2004
confirmed the major features of the previous AWA observations with better
precision and made additional measurements relevant to the calorimetric
capabilities of the method. Prompted by these results we built a prototype
detector using satellite television technology, and have made measurements
indicating possible detection of cosmic ray extensive air showers. The method,
if confirmed by experiments now in progress, could provide a high-duty cycle
complement to current nitrogen fluorescence observations of UHECR, which are
limited to dark, clear nights. By contrast, decimeter microwave observations
can be made both night and day, in clear or cloudy weather, or even in the
presence of moderate precipitation.Comment: 15 pages, 13 figure
Observations of the Askaryan Effect in Ice
We report on the first observations of the Askaryan effect in ice: coherent
impulsive radio Cherenkov radiation from the charge asymmetry in an
electromagnetic (EM) shower. Such radiation has been observed in silica sand
and rock salt, but this is the first direct observation from an EM shower in
ice. These measurements are important since the majority of experiments to date
that rely on the effect for ultra-high energy neutrino detection are being
performed using ice as the target medium. As part of the complete validation
process for the Antarctic Impulsive Transient Antenna (ANITA) experiment, we
performed an experiment at the Stanford Linear Accelerator Center (SLAC) in
June 2006 using a 7.5 metric ton ice target, yielding results fully consistent
with theoretical expectations.Comment: 4 pages, 5 figures, minor correction
Cosmic Rays: The Second Knee and Beyond
We conduct a review of experimental results on Ultra-High Energy Cosmic Rays
(UHECR's) including measurements of the features of the spectrum, the
composition of the primary particle flux and the search for anisotropy in event
arrival direction. We find that while there is a general consensus on the
features in the spectrum -- the Second Knee, the Ankle, and (to a lesser
extent) the GZK Cutoff -- there is little consensus on the composition of the
primaries that accompany these features. This lack of consensus on the
composition makes interpretation of the agreed upon features problematic. There
is also little direct evidence about potential sources of UHECRs, as early
reports of arrival direction anisotropies have not been confirmed in
independent measurements.Comment: 46 pages, 30 figures. Topical Review to appear in J. Physics
Astrometric calibration and performance of the Dark Energy Camera
We characterize the ability of the Dark Energy Camera (DECam) to perform
relative astrometry across its 500~Mpix, 3 deg^2 science field of view, and
across 4 years of operation. This is done using internal comparisons of ~4x10^7
measurements of high-S/N stellar images obtained in repeat visits to fields of
moderate stellar density, with the telescope dithered to move the sources
around the array. An empirical astrometric model includes terms for: optical
distortions; stray electric fields in the CCD detectors; chromatic terms in the
instrumental and atmospheric optics; shifts in CCD relative positions of up to
~10 um when the DECam temperature cycles; and low-order distortions to each
exposure from changes in atmospheric refraction and telescope alignment. Errors
in this astrometric model are dominated by stochastic variations with typical
amplitudes of 10-30 mas (in a 30 s exposure) and 5-10 arcmin coherence length,
plausibly attributed to Kolmogorov-spectrum atmospheric turbulence. The size of
these atmospheric distortions is not closely related to the seeing. Given an
astrometric reference catalog at density ~0.7 arcmin^{-2}, e.g. from Gaia, the
typical atmospheric distortions can be interpolated to 7 mas RMS accuracy (for
30 s exposures) with 1 arcmin coherence length for residual errors. Remaining
detectable error contributors are 2-4 mas RMS from unmodelled stray electric
fields in the devices, and another 2-4 mas RMS from focal plane shifts between
camera thermal cycles. Thus the astrometric solution for a single DECam
exposure is accurate to 3-6 mas (0.02 pixels, or 300 nm) on the focal plane,
plus the stochastic atmospheric distortion.Comment: Submitted to PAS
- …