14 research outputs found

    Sicilia—silicon carbide detectors for intense luminosity investigations and applications

    Get PDF
    Silicon carbide (SiC) is a compound semiconductor, which is considered as a possible alternative to silicon for particles and photons detection. Its characteristics make it very promising for the next generation of nuclear and particle physics experiments at high beam luminosity. Silicon Carbide detectors for Intense Luminosity Investigations and Applications (SiCILIA) is a project starting as a collaboration between the Italian National Institute of Nuclear Physics (INFN) and IMM-CNR, aiming at the realization of innovative detection systems based on SiC. In this paper, we discuss the main features of silicon carbide as a material and its potential application in the field of particles and photons detectors, the project structure and the strategies used for the prototype realization, and the first results concerning prototype production and their performance

    Detailed reproduction of the neutron emission from the compact DT neutron generator used as an in-situ 14 MeV calibration neutron source at JET

    Get PDF
    A compact DT neutron generator (NG) based on the mixed-beam operation was used as a calibration neutron source in the latest in-situ calibration of neutron detectors at the Joint European Torus (JET). In order to meet the requirement for the total uncertainty of the neutron detector calibration below ±10 %, the neutron emission properties had to be experimentally characterized and reproduced through detailed modelling of the neutron source characteristics and geometry of the neutron generator. The detailed neutronics simulations were an essential part of both NG characterization and JET neutron detector calibration. The complex neutron emission properties of the NG were reproduced through a combination of simulations and highresolution neutron spectroscopy measurements. This meant that six different DT neutron source components resulting from NG's mixed beam operation were explicitly simulated and their relative intensities scaled based on experimentally obtained neutron spectrum measurements. Furthermore, the detailed model of the NG's geometry was produced based on information from the supplier of the NG and images from a computer tomography (CT) scan. Finally, the positioning of the neutron source inside the JET tokamak during in-situ calibration was reproduced based on the information from the remote handling system (RHS) at JET, the system responsible for the positioning of the source during the calibration experiment. The extensive effort presented in the paper significantly contributed to the total uncertainties of the calibration factors well within the target value of ±10 %

    Detailed reproduction of the neutron emission from the compact DT neutron generator used as an in-situ 14 MeV calibration neutron source at JET

    No full text
    A compact DT neutron generator (NG) based on the mixed-beam operation was used as a calibration neutron source in the latest in-situ calibration of neutron detectors at the Joint European Torus (JET). In order to meet the requirement for the total uncertainty of the neutron detector calibration below ±10 %, the neutron emission properties had to be experimentally characterized and reproduced through detailed modelling of the neutron source characteristics and geometry of the neutron generator. The detailed neutronics simulations were an essential part of both NG characterization and JET neutron detector calibration. The complex neutron emission properties of the NG were reproduced through a combination of simulations and highresolution neutron spectroscopy measurements. This meant that six different DT neutron source components resulting from NG's mixed beam operation were explicitly simulated and their relative intensities scaled based on experimentally obtained neutron spectrum measurements. Furthermore, the detailed model of the NG's geometry was produced based on information from the supplier of the NG and images from a computer tomography (CT) scan. Finally, the positioning of the neutron source inside the JET tokamak during in-situ calibration was reproduced based on the information from the remote handling system (RHS) at JET, the system responsible for the positioning of the source during the calibration experiment. The extensive effort presented in the paper significantly contributed to the total uncertainties of the calibration factors well within the target value of ±10 %

    Development of the BAND-GEM detector solution for SANS experiments

    No full text
    New high count rate detectors are needed for future spallation neutron sources where large areas and high efficiency (>50%) detectors are envisaged. In this framework, GEM is one of the explored detector technologies since they feature good spatial resolution ( 20% in the wavelength range of interest for SANS instruments. A system of thin lamellas (250 ÎĽm) of dielectric material coated with 1 ÎĽm layer of 10^{10}B4_{4}C has been built and positioned in the first detector gap, orthogonally to the cathode. By tilting the lamellas system with respect to the beam, there is a significant increase of effective thickness of the borated material crossed by the neutrons. As a consequence, both interaction probability and detection efficiency are increased. This paper presents the results of the performance of the first prototype of BAND-GEM detector in terms of efficiency (as a function of tilting angle)

    Diffraction measurements with a boron-based GEM neutron detector

    No full text
    The research of reliable substitutes of 3He detectors is an important task for the affordability of new neutron scattering instrumentation for future spallation sources like the European Spallation Source. GEM (Gas Electron Multiplier)-based detectors represent a valid alternative since they can combine high-rate capability, coverage of up to 1 m21\ \text{m}^{2} area and good intrinsic spatial resolution (for this detector class it can be better than 0.5 mm). The first neutron diffraction measurements performed using a borated GEM detector are reported. The detector has an active area of 10×5 cm210 \times 5\ \text{cm}^{2} and is equipped with a borated cathode. The GEM detector was read out using the standard ISIS Data Acquisition System. The comparison with measurements performed with standard 3He detectors shows that the broadening of the peaks measured on the diffractogram obtained with the GEM is 20–30% wider than the one obtained by 3He tubes but the active area of the GEM is twice that of 3He tubes. The GEM resolution is improved if half of its active area is considered. The signal-to-background ratio of the GEM is about 1.5 to 2 times lower than that of 3He. This measurement proves that GEM detectors can be used for neutron diffraction measurements and paves the way for their use at future neutron spallation sources

    Thermal and fast neutron detection with two CLYC scintillators

    No full text
    © 2014 IEEE. The crystal Cs2LiYCl6:Ce (CLYC) is a very interesting scintillator material because of its excellent energy resolution and its capability to identify gamma rays and fast/thermal neutrons. In this work, the response to gamma, thermal and fast neutrons of two CLYC 1x1 crystals was measured: the first one, enriched with 6Li at 95% is ideal for thermal neutron measurements while the second one, enriched with 7Li at 99% is suitable for fast neutron measurements. The crystals were coupled to quartz window R6231-1000MOD HAMAMATSU PMTs. The thermal neutrons were measured in both detectors using an AmBe source in the gamma spectroscopy laboratory of the University of Milano, Italy. The measurements of fast neutrons were performed at Frascati (Italy) Neutron Generator facility providing neutrons of 14.1 MeV and 2.5 MeV.status: publishe

    Evolution in boron-based GEM detectors for diffraction measurements : From planar to 3D converters

    No full text
    The so-called '3He-crisis' has motivated the neutron detector community to undertake an intense R&D programme in order to develop technologies alternative to standard 3He tubes and suitable for neutron detection systems in future spallation sources such as the European spallation source (ESS). Boron-based GEM (gas electron multiplier) detectors are a promising '3He-free' technology for thermal neutron detection in neutron scattering experiments. In this paper the evolution of boron-based GEM detectors from planar to 3D converters with an application in diffraction measurements is presented. The use of 3D converters coupled with GEMs allows for an optimization of the detector performances. Three different detectors were used for diffraction measurements on the INES instrument at the ISIS spallation source. The performances of the GEM-detectors are compared with those of conventional 3He tubes installed on the INES instrument. The conceptual detector with the 3D converter used in this paper reached a count rate per unit area of about 25% relative to the currently installed 3He tube. Its timing resolution is similar and the signal-to-background ratio (S/B) is 2 times lower

    I-BAND-GEM : a new way for improving BAND-GEM efficiency to thermal and cold neutrons

    No full text
    .The BAND-GEM detector represents one of the novel thermal neutron detection devices that have been developed in order to fulfil the needs of high intensity neutron sources that, like ESS (the European Spallation Source), will start operation in the next few years. The first version of this detector featured a detection efficiency of about 40% for neutrons with a wavelength of 4 angstrom, a spatial resolution of about 6mm and a rate capability in the order of some MHz/cm(2). The novelty of this device is represented by an improved 3D converter cathode (10 cm thick) based on (B4C)-B-10-coated aluminum grids positioned in a controlled gas mixture volume put on top of a Triple GEM amplifying stage. The position where the neutron interacts in the converter depends on their energy and it was observed that the first version of the detector would suffer from an efficiency decrease for long (>5 angstrom) neutron wavelength. This paper describes how the new 3D cathode allowed improving the detection efficiency at long neutron wavelengths while keeping all the benefits of the first BAND-GEM version
    corecore