3,902 research outputs found

    Evaluation of the first automated thyroglobulin assay

    Get PDF
    The aim of this study was to investigate technical and analytical performance of the first automated thyroglobulin (Tg) assay (DPC-Immulite(R); Diagnostic Products Corporation, Los Angeles, USA). In imprecision studies using several human serum pools ranging from 21 to 58 replicates, a coefficient of variation of 9.0 % was obtained at a mean Tg concentration of 0.84 ng/ml and of 6.1 % at a Tg concentration of 62.1 ng/ml. In a method comparison with a non-automated assay (BRAHMS LUMItest Tg(R), BRAHMS, Berlin, Germany) using 383 sera of 303 patients with thyroid carcinoma, regression analysis according to Passing and Bablock yielded in the following equation: Immulite Tg=1.6 x BRAHMS Tg - 0.1 ng/ml (Pearson's r=0.979). Sera obtained from 59 patients with thyroid carcinoma enabled comparative follow-up studies; in all cases qualitative agreement was found with regard to increase or decrease of serum Tg; in eight cases, however, Tg was detected with the Immulite assay but not with the BRAHMS assay. Further follow-up proved the presence of thyroid tissue in these patients. From these and further methodological data (dilution linearity, interference studies, carry-over study, high-dose hook properties, and short report time) it is concluded that the DPC-Immulite Tg assay meets the requirements of routine diagnostic use

    Deep far infrared ISOPHOT survey in "Selected Area 57", I. Observations and source counts

    Get PDF
    We present here the results of a deep survey in a 0.4 sq.deg. blank field in Selected Area 57 conducted with the ISOPHOT instrument aboard ESAs Infrared Space Observatory (ISO) at both 60 um and 90 um. The resulting sky maps have a spatial resolution of 15 x 23 sq.arcsec. per pixel which is much higher than the 90 x 90 sq.arcsec. pixels of the IRAS All Sky Survey. We describe the main instrumental effects encountered in our data, outline our data reduction and analysis scheme and present astrometry and photometry of the detected point sources. With a formal signal to noise ratio of 6.75 we have source detection limits of 90 mJy at 60 um and 50 mJy at 90 um. To these limits we find cumulated number densities of 5+-3.5 per sq.deg. at 60 um and 14.8+-5.0 per sq.deg.at 90 um. These number densities of sources are found to be lower than previously reported results from ISO but the data do not allow us to discriminate between no-evolution scenarios and various evolutionary models.Comment: 15 pages, 11 figures, accepted by Astronomy & Astrophysic

    Measuring the equation of state of a hard-disc fluid

    Full text link
    We use video microscopy to study a two-dimensional (2D) model fluid of charged colloidal particles suspended in water and compute the pressure from the measured particle configurations. Direct experimental control over the particle density by means of optical tweezers allows the precise measurement of pressure as a function of density. We compare our data with theoretical predictions for the equation of state, the pair-correlation function and the compressibility of a hard-disc fluid and find good agreement, both for the fluid and the solid phase. In particular the location of the transition point agrees well with results from Monte Carlo simulations.Comment: 7 pages, to appear in EPL, slightly corrected versio

    Safety and convenience of once-weekly somapacitan in adult GH deficiency: a 26-week randomized, controlled trial

    Get PDF
    OBJECTIVE: Somapacitan is a reversible albumin-binding growth hormone (GH) derivative, developed for once-weekly administration. This study aimed to evaluate the safety of once-weekly somapacitan vs once-daily Norditropin. Local tolerability and treatment satisfaction were also assessed. DESIGN: 26-week randomized, controlled phase 3 safety and tolerability trial in six countries (Nbib2382939). METHODS: Male or female patients aged 18-79 years with adult GH deficiency (AGHD), treated with once-daily GH for ≥6 months, were randomized to once-weekly somapacitan ( = 61) or once-daily Norditropin ( = 31) administered subcutaneously by pen. Both treatments were dose titrated for 8 weeks to achieve insulin-like growth factor I (IGF-I) standard deviation score (SDS) levels within the normal range, and then administered at a fixed dose. Outcome measures were adverse events (AEs), including injection site reactions; occurrence of anti-somapacitan/anti-GH antibodies and change in treatment satisfaction, assessed using the Treatment Satisfaction Questionnaire for Medication-9 (TSQM-9). RESULTS: Mean IGF-I SDS remained between 0 and 2 SDS throughout the trial in both groups. AEs were mostly mild or moderate and transient in nature. The most common AEs were nasopharyngitis, headache and fatigue in both groups. More than 1500 somapacitan injections were administered and no clinically significant injection site reactions were reported. No anti-somapacitan or anti-GH antibodies were detected. The TSQM-9 score for convenience increased significantly more with somapacitan vs Norditropin ( = 0.0171). CONCLUSIONS: In this 26-week trial in patients with AGHD, somapacitan was well tolerated and no safety issues were identified. Once-weekly somapacitan was reported to be more convenient than once-daily Norditropin

    On the performance of the intermediate Hamiltonian Fock-space coupled-cluster method on linear triatomic molecules: The electronic spectra of NpO2+, NpO22+, and Pu O22

    Get PDF
    International audienceIn this paper we explore the use of the novel relativistic intermediate Hamiltonian Fock-space coupled-cluster method in the calculation of the electronic spectrum for small actinyl ions (NpO2+, NpO22+, and PuO22+). It is established that the method, in combination with uncontracted double-zeta quality basis sets, yields excitation energies in good agreement with experimental values, and better than those obtained previously with other theoretical methods. We propose the reassignment of some of the peaks that were observed experimentally, and confirm other assignments

    A device for extraction, manipulation and stretching of DNA from single human chromosomes

    Get PDF
    We describe the structure and operation of a micro/nanofluidic device in which individual metaphase chromosomes can be isolated and processed without being displaced during exchange of reagents. The change in chromosome morphology as a result of introducing protease into the device was observed by time-lapse imaging; pressure-driven flow was then used to shunt the chromosomal DNA package into a nanoslit. A long linear DNA strand (>1.3 Mbp) was seen to stretch out from the DNA package and along the length of the nanoslit. Delivery of DNA in its native metaphase chromosome package as well as the microfluidic environment prevented DNA from shearing and will be important for preparing ultra-long lengths of DNA for nanofluidic analysis
    • …
    corecore