52 research outputs found

    Special Section Guest Editorial: Pioneer in Biomedical Optics: Introduction to the Special Section in Honor of Steven L. Jacques

    Get PDF
    This guest editorial introduces the special section honoring Prof. Steven L. Jacques. We present this special section of the Journal of Biomedical Optics in honor of Steven L. Jacques, PhD, a leading pioneer in the field of biomedical optics. In the late eighties, Steve was part of a small group of researchers from various disciplines who clearly saw the potential of light and optics for new approaches to medical diagnostics and treatment of various diseases. Since then the field has grown exponentially and biomedical optics has become an integral part in many medical disciplines. Through his work and many seminal contributions, Steve has actively shaped this development

    In Vitro Evaluation of Fluorescence Glucose Biosensor Response

    Get PDF
    Rapid, accurate, and minimally-invasive glucose biosensors based on Förster Resonance Energy Transfer (FRET) for glucose measurement have the potential to enhance diabetes control. However, a standard set of in vitro approaches for evaluating optical glucose biosensor response under controlled conditions would facilitate technological innovation and clinical translation. Towards this end, we have identified key characteristics and response test methods, fabricated FRET-based glucose biosensors, and characterized biosensor performance using these test methods. The biosensors were based on competitive binding between dextran and glucose to concanavalin A and incorporated long-wavelength fluorescence dye pairs. Testing characteristics included spectral response, linearity, sensitivity, limit of detection, kinetic response, reversibility, stability, precision, and accuracy. The biosensor demonstrated a fluorescence change of 45% in the presence of 400 mg/dL glucose, a mean absolute relative difference of less than 11%, a limit of detection of 25 mg/dL, a response time of 15 min, and a decay in fluorescence intensity of 72% over 30 days. The battery of tests presented here for objective, quantitative in vitro evaluation of FRET glucose biosensors performance have the potential to form the basis of future consensus standards. By implementing these test methods for a long-visible-wavelength biosensor, we were able to demonstrate strengths and weaknesses with a new level of thoroughness and rigor

    Special Section Guest Editorial: Pioneer in Biomedical Optics: Introduction to the Special Section in Honor of Steven L. Jacques

    Get PDF
    This guest editorial introduces the special section honoring Prof. Steven L. Jacques. We present this special section of the Journal of Biomedical Optics in honor of Steven L. Jacques, PhD, a leading pioneer in the field of biomedical optics. In the late eighties, Steve was part of a small group of researchers from various disciplines who clearly saw the potential of light and optics for new approaches to medical diagnostics and treatment of various diseases. Since then the field has grown exponentially and biomedical optics has become an integral part in many medical disciplines. Through his work and many seminal contributions, Steve has actively shaped this development

    Mueller matrix imaging for collagen scoring in mice model of pregnancy

    Get PDF
    Preterm birth risk is associated with early softening of the uterine cervix in pregnancy due to the accelerated remodeling of collagen extracellular matrix. Studies of mice model of pregnancy were performed with an imaging Mueller polarimeter at different time points of pregnancy to find polarimetric parameters for collagen scoring. Mueller matrix images of the unstained sections of mice uterine cervices were taken at day 6 and day 18 of 19-days gestation period and at different spatial locations through the cervices. The logarithmic decomposition of the recorded Mueller matrices mapped the depolarization, linear retardance, and azimuth of the optical axis of cervical tissue. These images highlighted both the inner structure of cervix and the arrangement of cervical collagen fibers confirmed by the second harmonic generation microscopy. The statistical analysis and two-Gaussians fit of the distributions of linear retardance and linear depolarization in the entire images of cervical tissue (without manual selection of the specific regions of interest) quantified the randomization of collagen fibers alignment with gestation time. At day 18 the remodeling of cervical extracellular matrix of collagen was measurable at the external cervical os that is available for the direct optical observations in vivo. It supports the assumption that imaging Mueller polarimetry holds promise for the fast and accurate collagen scoring in pregnancy and the assessment of the preterm birth risk

    Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring

    Get PDF
    Photoplethysmography (PPG) is a low-cost, noninvasive optical technique that uses change in light transmission with changes in blood volume within tissue to provide information for cardiovascular health and fitness. As remote health and wearable medical devices become more prevalent, PPG devices are being developed as part of wearable systems to monitor parameters such as heart rate (HR) that do not require complex analysis of the PPG waveform. However, complex analyses of the PPG waveform yield valuable clinical information, such as: blood pressure, respiratory information, sympathetic nervous system activity, and heart rate variability. Systems aiming to derive such complex parameters do not always account for realistic sources of noise, as testing is performed within controlled parameter spaces. A wearable monitoring tool to be used beyond fitness and heart rate must account for noise sources originating from individual patient variations (e.g., skin tone, obesity, age, and gender), physiology (e.g., respiration, venous pulsation, body site of measurement, and body temperature), and external perturbations of the device itself (e.g., motion artifact, ambient light, and applied pressure to the skin). Here, we present a comprehensive review of the literature that aims to summarize these noise sources for future PPG device development for use in health monitoring

    Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI)

    Get PDF
    Cardiovascular disease is one of the leading causes of death in the United States and obesity significantly increases the risk of cardiovascular disease. The measurement of blood pressure (BP) is critical in monitoring and managing cardiovascular disease hence new wearable devices are being developed to make BP more accessible to physicians and patients. Several wearables utilize photoplethysmography from the wrist vasculature to derive BP assessment although many of these devices are still at the experimental stage. With the ultimate goal of supporting instrument development, we have developed a model of the photoplethysmographic waveform derived from the radial artery at the volar surface of the wrist. To do so we have utilized the relation between vessel biomechanics through Finite Element Method and Monte Carlo light transport model. The model shows similar features to that seen in PPG waveform captured using an off the shelf device. We observe the influence of body mass index on the PPG signal. A degradation the PPG signal of up to 40% in AC to DC signal ratio was thus observed

    Symmetric decomposition of Mueller matrices reveals a new parametric space for polarimetric assistance in colon cancer histopathology

    Get PDF
    Tissue polarimetry could be identified as a complementary optical and non-invasive technique to assist the gold standard histopathology analysis of tissue. In general, polarimetric diagnostics is based on tracing different polarimetric responses (including light depolarization) in tissue zones with structure altered by the benign and pre/cancerous formations. In this manuscript, both healthy and malignant tissue zones of a thick formalin-fixed colon specimen were used for Mueller matrix measurements. Additionally, two more Mueller matrices from Monte Carlo simulation and tissue mimicking phantom were also evaluated, in order to assess polarimetric char- acterization and modeling of turbid media. Symmetric decomposition algorithm of Mueller matrices developed in house was adopted to extract both polarization and depolarization properties, encoded in the Mueller matrix elements. The decomposition products allowed to reveal important information about the internal tissue struc- ture and morphology. The depolarization and polarization parameters were found to follow the particular trends that depend on a choice of parametric space

    The 2023 wearable photoplethysmography roadmap

    Get PDF
    Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology
    • …
    corecore