97 research outputs found

    The Effect of Hydrofluoric Acid Etching Duration on the Surface Micromorphology, Roughness, and Wettability of Dental Ceramics

    Get PDF
    The current laboratory study is evaluating the effect of hydrofluoric acid etching duration on the surface characteristics of five silica-based glass ceramics. Changes in the pore pattern, crystal structure, roughness, and wettability were compared and evaluated. Seventy-five rectangularly shaped specimens were cut from each material (IPS e-max (TM), Dentsply Celtra (TM), Vita Suprinity (TM), Vita mark II (TM), and Vita Suprinity FC (TM)); the sectioned samples were finished, polished, and ultrasonically cleaned. Specimens were randomly assigned into study groups: control (no etching) and four experimental groups (20, 40, 80 and 160 s of etching). The etched surfaces' microstructure including crystal structure, pore pattern, pore depth, and pore width was studied under a scanning electron microscope, and the surface roughness and wettability were analyzed using a non-contact surface profilometer and a contact angle measuring device, respectively. The results were statistically analyzed using one-way analysis of variance (ANOVA) and the post hoc Tukey's test. The results showed a significant change in the pore number, pore pattern, crystal structure, surface roughness, and wettability with increased etching duration. Etching for a short time resulted in small pores, and etching for longer times resulted in wider, irregular grooves. A significant increase in the surface roughness and wettability was observed with an increase in the etching duration. The findings also suggested a strong association between the surface roughness and wettability

    Assessment of CAD-CAM polymers for digitally fabricated complete dentures

    Get PDF
    Statement of problemInformation on the mechanical properties of the materials used for manufacturing computer-engineered complete dentures is scarce.PurposeThe purpose of this in vitro study was to evaluate the mechanical properties of 3 prepolymerized polymethyl methacrylate (PMMA) resins used in the fabrication of computer-aided design and computer-aided manufacturing (CAD-CAM) milled complete dentures (CDs), as well as 2 denture base polymers used for conventionally fabricated CDs.Material and methodsThree CAD-CAM materials were evaluated: Degos Dental L-Temp, IvoBase CAD, and Zirkonzahn Temp Basic Tissue. Two materials used for conventionally manufactured dentures were also included as controls (Palapress and Paladon 65). Each material type was sectioned into bars for flexural strength, nanohardness, elastic modulus, and surface microhardness evaluation (n=8/material). Half of the specimens were stored in water for 30 days, while the other half was dry-stored. A 2-way ANOVA was conducted to detect the effect of material and storage on the evaluated properties (α=.05). Linear contrasts were conducted to compare the differences among the 3 types of CAD-CAM material and the conventional ones.ResultsMaterial type and storage had a significant influence on the flexural strength, nanohardness, elastic modulus, and surface hardness of the materials investigated (PP=1.000). In terms of nanohardness, no difference was found when comparing Palapress with Paladon, as well as IvoBase CAD with Zirkonzahn Temp Basic (P=1.000). A nonsignificant interaction in terms of surface hardness was also found between IvoBase CAD and Palapress (P=.575).ConclusionsThe tested materials showed variation in their mechanical properties, with satisfactory behavior of the CAD-CAM materials. However, the results obtained when testing the materials used for the conventional fabrication of complete dentures suggest that their use might still be advisable.</div

    Preliminary fabrication and characterization of electron beam melted Ti-6Al-4V customized dental implant

    Get PDF
    The current study was aimed to fabricate customized root form dental implant using additive manufacturing technique for the replacement of missing teeth. The root form dental implant was designed using Geomagic (TM) and Magics (TM), the designed implant was directly manufactured by layering technique using ARCAM A2 (TM) electron beam melting system by employing medical grade Ti- 6Al-4V alloy powder. Furthermore, the fabricated implant was characterized in terms of certain clinically important parameters such as surface microstructure, surface topography, chemical purity and internal porosity. Results confirmed that, fabrication of customized dental implants using additive rapid manufacturing technology offers an attractive method to produce extremely pure form of customized titanium dental implants, the rough and porous surface texture obtained is expected to provide better initial implant stabilization and superior osseointegration. (C) 2016 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University

    Mother’s physical activity during pregnancy and newborn’s brain cortical development

    Get PDF
    Background Physical activity is known to improve mental health, and is regarded as safe and desirable for uncomplicated pregnancy. In this novel study, we aim to evaluate whether there are associations between maternal physical activity during pregnancy and neonatal brain cortical development. Methods Forty-four mother/newborn dyads were included in this longitudinal study. Healthy pregnant women were recruited and their physical activity throughout pregnancy were documented using accelerometers worn for 3–7 days for each of the 6 time points at 4–10, ∼12, ∼18, ∼24, ∼30, and ∼36 weeks of pregnancy. Average daily total steps and daily total activity count as well as daily minutes spent in sedentary/light/moderate/vigorous activity modes were extracted from the accelerometers for each time point. At ∼2 weeks of postnatal age, their newborns underwent an MRI examination of the brain without sedation, and 3D T1-weighted brain structural images were post-processed by the iBEAT2.0 software utilizing advanced deep learning approaches. Cortical surface maps were reconstructed from the segmented brain images and parcellated to 34 regions in each brain hemisphere, and mean cortical thickness for each region was computed for partial correlation analyses with physical activity measures, with appropriate multiple comparison corrections and potential confounders controlled.ResultsAt 4–10 weeks of pregnancy, mother’s daily total activity count positively correlated (FDR corrected P ≤ 0.05) with newborn’s cortical thickness in the left caudal middle frontal gyrus (rho = 0.48, P = 0.04), right medial orbital frontal gyrus (rho = 0.48, P = 0.04), and right transverse temporal gyrus (rho = 0.48, P = 0.04); mother’s daily time in moderate activity mode positively correlated with newborn’s cortical thickness in the right transverse temporal gyrus (rho = 0.53, P = 0.03). At ∼24 weeks of pregnancy, mother’s daily total activity count positively correlated (FDR corrected P ≤ 0.05) with newborn’s cortical thickness in the left (rho = 0.56, P = 0.02) and right isthmus cingulate gyrus (rho = 0.50, P = 0.05). Conclusion We identified significant relationships between physical activity in healthy pregnant women during the 1st and 2nd trimester and brain cortical development in newborns. Higher maternal physical activity level is associated with greater neonatal brain cortical thickness, presumably indicating better cortical development

    Applications of raman spectroscopy in dentistry part II: Soft tissue analysis

    Get PDF
    Raman spectroscopy is rapidly moving from an experimental technique for the analysis of biological molecules to a tool for the real-time clinical diagnosis and in situ evaluation of the oral tissue in medical and dental research. The purpose of this study is to identify various applications of Raman spectroscopy, to evaluate the contemporary status and to explore future directions in the field of dentistry. Several in-depth applications are presented to illustrate Raman spectroscopy in early diagnosis of soft tissue abnormalities. Raman spectroscopy allows to analyze histological and biochemical composition of biological tissues. The technique not only demonstrates its role in the disclosure of dysplasia and malignancy but also in performing guided biopsies, diagnosing sialoliths, and assessment of surgical margins. Raman spectroscopy is used to identify the molecular structures and its components to give substantial information about the chemical structure properties of these molecules. In this paper, we acquaint the utilization of Raman spectroscopy in analyzing the soft tissues in relation to dentistry

    Occurrence of vancomycin-resistant Staphylococcus aureus in the oral cavity of patients with dental caries

    Get PDF
    Oral streptococci are the major group of microbes isolated from oral microflora. They represent frequent pathogens of infective endocarditis (IE), and it is assumed that in most of the cases oral streptococci are acquired via mucosa layer of oral cavity. Staphylococcus aureus is also frequently isolated from IE as it accounts for 20%–30% of all cases. Vancomycin has been the most reliable therapeutic agent against infections caused by methicillin-resistant S. aureus (MRSA). The main objective of this study was to examine the occurrence of S. aureus species in dental caries specimens. Antimicrobial susceptibility testing of S. aureus to four antibiotics namely vancomycin, linezolid, teicoplanin, and daptomycin was performed. Detection of vancomycin resistance was conducted using polymerase chain reaction. Among the tested 150 strains, 98 were MRSA and of that 54 were vancomycin sensitive and 27 were resistant. All 98 MRSA strains were positive for mecA and 36 yielded pvl, whereas 13 carried vanA and only 2 were positive for vanB. Majority of the isolates showed sensitivity toward daptomycin and linezolid. Strains of S. aureus exhibiting decreased susceptibility to different antibiotics like vancomycin, daptomycin, and linezolid severely compromise the therapeutic alternatives and require a considerable amount of time, public awareness, and integrative health-care strategies to prevent the emergence of resistance to these compounds

    RNA delivery by extracellular vesicles in mammalian cells and its applications.

    Get PDF
    The term 'extracellular vesicles' refers to a heterogeneous population of vesicular bodies of cellular origin that derive either from the endosomal compartment (exosomes) or as a result of shedding from the plasma membrane (microvesicles, oncosomes and apoptotic bodies). Extracellular vesicles carry a variety of cargo, including RNAs, proteins, lipids and DNA, which can be taken up by other cells, both in the direct vicinity of the source cell and at distant sites in the body via biofluids, and elicit a variety of phenotypic responses. Owing to their unique biology and roles in cell-cell communication, extracellular vesicles have attracted strong interest, which is further enhanced by their potential clinical utility. Because extracellular vesicles derive their cargo from the contents of the cells that produce them, they are attractive sources of biomarkers for a variety of diseases. Furthermore, studies demonstrating phenotypic effects of specific extracellular vesicle-associated cargo on target cells have stoked interest in extracellular vesicles as therapeutic vehicles. There is particularly strong evidence that the RNA cargo of extracellular vesicles can alter recipient cell gene expression and function. During the past decade, extracellular vesicles and their RNA cargo have become better defined, but many aspects of extracellular vesicle biology remain to be elucidated. These include selective cargo loading resulting in substantial differences between the composition of extracellular vesicles and source cells; heterogeneity in extracellular vesicle size and composition; and undefined mechanisms for the uptake of extracellular vesicles into recipient cells and the fates of their cargo. Further progress in unravelling the basic mechanisms of extracellular vesicle biogenesis, transport, and cargo delivery and function is needed for successful clinical implementation. This Review focuses on the current state of knowledge pertaining to packaging, transport and function of RNAs in extracellular vesicles and outlines the progress made thus far towards their clinical applications
    • …
    corecore