11 research outputs found

    ADAPTATION OF LITTLEARS AUDITORY QUESTIONNAIRE IN TAMIL

    Get PDF
    Objectives: To adapt the LittlEARS Questionnaire in Tamil language and evaluate it in Tamil speaking cochlear implant children. Methods: LEAQ was translated to the Tamil language by a back-translation method following the guidelines of the World Health Organisation. The translated version was later administered to 100 randomly selected parents of cochlear implantees, scoring was done out of 35 for each child. Statistical analysis was done using SPSS software version 20.0 were descriptive statistics were carried out extracting the mean, standard deviation and range. Results: The results got did not significantly deviate from the normative, thus being able to quantify hierarchical auditory development skills and performance of children. Conclusion: LEAQ is a good subjective tool that can measure the outcome of cochlear implant/hearing aids, it must be translated and validated based on cultural and linguistic background.  Article visualizations

    Audiological practice and COVID-19: recommendations that audiological centers can use to maintain the safety and quality of service-expert opinion

    No full text
    Purpose Audiology is an essential service for some patient groups and some interventions. This article sets forth experience-based recommendations for how audiological centers can continue to safely and effectively function during COVID-19. Methods The recommendations are the result of panel discussion and are based on the clinical experience of the panelists/authors. Results The recommendations cover which patient groups and which interventions should be treated when and whether this can be performed in the clinic or remotely; how to maintain the safety of workplace via optimizing patient flow within the clinic and the sanitation of rooms and equipment; and overcoming communication challenges that COVID-19 intensifies. Conclusion For essential audiological services to continue under COVID-19, safety measures must be implemented and maintained, and treatment and communication strategies must be adapted to offset communication difficulties due to personal protective equipment (PPE) and social distancing and to bolster patient confidence. In short, it is vital that staff feel safe, that patients either feel the clinic is safe enough to visit or that remote treatment may be an option, and that clinics and patients have a broad agreement on the urgency of any needed service. We hope that these recommendations help clinics effectively accomplish these goals

    Minimal outcome measurements in pediatric cochlear implant users : a consensus paper

    Get PDF
    The benefits of cochlear implantation in children with severe hearing impairments are widely known; however, there is no consensus regarding which minimal outcome measurements (MOMs) should be used to determine outcomes in this population with pediatric cochlear implant (CI). Therefore, the authors aim to propose a MOM test battery for pediatric CI recipients that can facilitate international multi-center research and collaboration. A pediatric MOM test battery was developed and agreed-upon by members of the HEARRING group across 30 expert clinics in the field of hearing implantation. The MOM test battery was chosen based on a literature search that focused on outcome measurements applied in clinical trials involving children with a hearing implant. Members of the HEARRING group were then asked to evaluate each of the pediatric MOM tests used. The final pediatric MOM test battery was defined for different chronological age categories (six weeks–18 years) at different suggested test intervals. The test battery includes objective hearing measurements, aided and unaided audiometry, speech perception tests in quiet and in noise, subjective hearing assessments, assessment of language development, and mental and motor development. This study presents a consensus on a MOM test battery for pediatric CI recipients that was agreed upon by members of the HEARRING group. This test battery should allow for international multi-center research to be able to extend and share evidence that will guide future clinical practice and research efforts in pediatric populations with CI.http://www.b-ent.beam2022Speech-Language Pathology and Audiolog

    Hearing preservation cochlear implantation in children:The HEARRING Group consensus and practice guide

    No full text
    International audienceOBJECTIVES: To provide multidisciplinary cochlear implant teams with a current consensus statement to support hearing preservation cochlear implantation (HPCI) in children, including those children with symptomatic partial deafness (PD) where the intention is to use electric-acoustic stimulation (EAS). The main objectives are to provide guidelines on who is a candidate, how to assess these children and when to implant if Med-El Flex electrode arrays are chosen for implantation. METHODS: The HEARRING group reviewed the current evidence and practice regarding the management of children to be considered for HPCI surgery emphasizing the assessment needed prior to implantation in order to demonstrate the benefits in these children over time. The consensus statement addresses following three key questions: (1) Should these children be treated? (2) How to identify these children? (3) How to manage these children? SUMMARY: The HEARRING group concludes that irrespective of the degree of residual hearing present, the concepts of hearing and structure preservation should be applied in every child undergoing cochlear implantation and that HPCI is a safe and reliable treatment option. Early detection and multidisciplinary assessment are key to the identification of children with symptomatic PD, these children should undergo HPCI as early as possible

    Quality standards for bone conduction implants.

    No full text
    CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints
    corecore