454 research outputs found

    Study made of corrosion resistance of stainless steel and nickel alloys in nuclear reactor superheaters

    Get PDF
    Experiments performed under conditions found in nuclear reactor superheaters determine the corrosion rate of stainless steel and nickel alloys used in them. Electropolishing was the primary surface treatment before the corrosion test. Corrosion is determined by weight loss of specimens after defilming

    Electromechanical Reliability Testing of Three-Axial Silicon Force Sensors

    Get PDF
    This paper reports on the systematic electromechanical characterization of a new three-axial force sensor used in dimensional metrology of micro components. The siliconbased sensor system consists of piezoresistive mechanicalstress transducers integrated in thin membrane hinges supporting a suspended flexible cross structure. The mechanical behavior of the fragile micromechanical structure isanalyzed for both static and dynamic load cases. This work demonstrates that the silicon microstructure withstands static forces of 1.16N applied orthogonally to the front-side of the structure. A statistical Weibull analysis of the measured data shows that these values are significantly reduced if the normal force is applied to the back of the sensor. Improvements of the sensor system design for future development cycles are derived from the measurement results.Comment: Submitted on behalf of TIMA Editions (http://irevues.inist.fr/tima-editions

    Bedload velocity and backscattering strength from mobile sediment bed: A laboratory investigation comparing bistatic versus monostatic acoustic configuration

    Get PDF
    Despite the many advantages of using active ultrasound sonars, recent studies have shown that the specific acoustic geometry, signal-processing configuration, and complex surface-volume scattering process at the riverbed introduce several uncertainties in bedload estimation. This study presents a comparison of bedload velocity and bottom echo intensity measurements performed by monostatic and bistatic active ultrasound systems. The monostatic configuration is widely applied in the field to measure the apparent velocity at the riverbed with an acoustic current Doppler profiler (ADCP). Two laboratory investigations were conducted in two different hydraulic facilities deploying ADCP Stream Pro, monostatic and bistatic acoustic velocity profilers, manufactured by Ubertone. The bistatic instruments provided more accurate bedload velocity measurements and helped in understanding the acoustic sampling of the monastic systems. The bistatic profiles succeeded in measuring a profile over the active bedload layer, and the monostatic instruments resulted in different bedload velocity estimations depending on the acoustic resolution and sampling. The echo intensity increased in the cells measured within the active bedload layer with respect to the cell measuring the water column above. The cells that sampled the immobile bed surface beneath the bedload layer showed a reduction of the echo intensity compared with the cells above. The acoustic sampling, which combines the measurement volume geometry and internal processing, seems crucial for more accurate outputs. Future research about the use of monostatic instruments in the field should aim to define the best possible setting for the acoustic parameters at a given bedload condition that may be tuned by evaluating the backscattering at the river bottom together with the apparent bedload velocity

    Best practice in undertaking and reporting health technology assessments : Working Group 4 report

    Get PDF
    [Executive Summary] The aim of Working Group 4 has been to develop and disseminate best practice in undertaking and reporting assessments, and to identify needs for methodologic development. Health technology assessment (HTA) is a multidisciplinary activity that systematically examines the technical performance, safety, clinical efficacy, and effectiveness, cost, costeffectiveness, organizational implications, social consequences, legal, and ethical considerations of the application of a health technology (18). HTA activity has been continuously increasing over the last few years. Numerous HTA agencies and other institutions (termed in this report “HTA doers”) across Europe are producing an important and growing amount of HTA information. The objectives of HTA vary considerably between HTA agencies and other actors, from a strictly political decision making–oriented approach regarding advice on market licensure, coverage in benefits catalogue, or investment planning to information directed to providers or to the public. Although there seems to be broad agreement on the general elements that belong to the HTA process, and although HTA doers in Europe use similar principles (41), this is often difficult to see because of differences in language and terminology. In addition, the reporting of the findings from the assessments differs considerably. This reduces comparability and makes it difficult for those undertaking HTA assessments to integrate previous findings from other HTA doers in a subsequent evaluation of the same technology. Transparent and clear reporting is an important step toward disseminating the findings of a HTA; thus, standards that ensure high quality reporting may contribute to a wider dissemination of results. The EUR-ASSESS methodologic subgroup already proposed a framework for conducting and reporting HTA (18), which served as the basis for the current working group. New developments in the last 5 years necessitate revisiting that framework and providing a solid structure for future updates. Giving due attention to these methodologic developments, this report describes the current “best practice” in both undertaking and reporting HTA and identifies the needs for methodologic development. It concludes with specific recommendations and tools for implementing them, e.g., by providing the structure for English-language scientific summary reports and a checklist to assess the methodologic and reporting quality of HTA reports

    Raman microscopy of lithium-manganese-rich transition metal oxide cathodes

    Get PDF
    Lithium-rich and manganese-rich (LMR) layered transition metal (TM) oxide composites with general formula xLi2MnO3 • (1- x)LiMO2 (M = Ni, Co, Mn) are promising cathode candidates for high energy density lithium ion batteries. Lithium-manganese-rich TM oxides crystallize as a nanocomposite layered phase whose structure further evolves with electrochemical cycling. Raman spectroscopy is a powerful tool to monitor the crystal chemistry and correlate phase changes with electrochemical behavior. While several groups have reported Raman spectra of lithium rich TM oxides, the data show considerable variability in terms of both the vibrational features observed and their interpretation. In this study, Raman microscopy is used to investigate lithium-rich and manganese-rich TM cathodes as a function of voltage and electrochemical cycling at various temperatures. No growth of a spinel phase is observed within the cycling conditions. However, analysis of the Raman spectra does indicate the structure of LMR-NMC deviates significantly from an ideal layered phase. The results also highlight the importance of using low laser power and large sample sizes to obtain consistent data sets

    Human monoclonal antibodies that neutralize anthrax toxin by inhibiting heptamer assembly

    Get PDF
    A panel of human anti-anthrax protective antigen IgG1 monoclonal antibodies were evaluated to determine the mechanism of toxin neutralization. AVP-22G12, AVP-1C6 and AVP-21D9 bound to the protective antigen with picomolar affinities to distinct non-overlapping linear epitopes. Two of the antibodies neutralized the anthrax toxin by completely inhibiting the protective antigen oligomer assembly process in vitro

    Courtship pheromones in parasitic wasps: comparison of bioactive and inactive hydrocarbon profiles by multivariate statistical methods

    Get PDF
    Cuticular hydrocarbons play a significant role in the regulation of cuticular permeability and also in the chemical communication of insects. In the parasitoid Lariophagus distinguendus (Hymenoptera: Pteromalidae), male courtship behavior is mediated by a female-produced sex pheromone. Previous studies have shown that the chemicals involved are already present in the pupal stage of both males and females. However, pheromonal activity in males decreases shortly after emergence. This pheromonal deactivation occurs only in living males, suggesting an active process rather than simple evaporation of bioactive compounds. Here, we present evidence that the sex pheromone of L. distinguendus is composed of a series of cuticular hydrocarbons. Filter paper disks treated with nonpolar fractions of cuticular extracts of freshly emerged males and females, 72-hr-old females, and yellowish pupae caused arrestment and stimulated key elements of courtship behavior in males, whereas fractions of 72-hr-old males did not. Sixty-four hydrocarbons with chain length between C25 and C37 were identified in the fractions by gas chromatography-mass spectrometry (GC-MS). Methyl-branched alkanes with one to four methyl groups were major components, along with traces of n-alkanes and monoalkenes. Principal component analysis, based on the relative amounts of the compounds, revealed that cuticular hydrocarbon composition differed among all five groups. By using partial least squares-discriminant analysis, we determined a series of components that differentiate bioactive and bioinactive hydrocarbon profiles, and may be responsible for pheromonal activity of hydrocarbon fractions in L. distinguendus

    Human anti-anthrax protective antigen neutralizing monoclonal antibodies derived from donors vaccinated with anthrax vaccine adsorbed

    Get PDF
    BACKGROUND: Potent anthrax toxin neutralizing human monoclonal antibodies were generated from peripheral blood lymphocytes obtained from Anthrax Vaccine Adsorbed (AVA) immune donors. The anti-anthrax toxin human monoclonal antibodies were evaluated for neutralization of anthrax lethal toxin in vivo in the Fisher 344 rat bolus toxin challenge model. METHODS: Human peripheral blood lymphocytes from AVA immunized donors were engrafted into severe combined immunodeficient (SCID) mice. Vaccination with anthrax protective antigen and lethal factor produced a significant increase in antigen specific human IgG in the mouse serum. The antibody producing lymphocytes were immortalized by hybridoma formation. The genes encoding the protective antibodies were rescued and stable cell lines expressing full-length human immunoglobulin were established. The antibodies were characterized by; (1) surface plasmon resonance; (2) inhibition of toxin in an in vitro mouse macrophage cell line protection assay and (3) in vivo in a Fischer 344 bolus lethal toxin challenge model. RESULTS: The range of antibodies generated were diverse with evidence of extensive hyper mutation, and all were of very high affinity for PA83~1 × 10(-10-11)M. Moreover all the antibodies were potent inhibitors of anthrax lethal toxin in vitro. A single IV dose of AVP-21D9 or AVP-22G12 was found to confer full protection with as little as 0.5× (AVP-21D9) and 1× (AVP-22G12) molar equivalence relative to the anthrax toxin in the rat challenge prophylaxis model. CONCLUSION: Here we describe a powerful technology to capture the recall antibody response to AVA vaccination and provide detailed molecular characterization of the protective human monoclonal antibodies. AVP-21D9, AVP-22G12 and AVP-1C6 protect rats from anthrax lethal toxin at low dose. Aglycosylated versions of the most potent antibodies are also protective in vivo, suggesting that lethal toxin neutralization is not Fc effector mediated. The protective effect of AVP-21D9 persists for at least one week in rats. These potent fully human anti-PA toxin-neutralizing antibodies are attractive candidates for prophylaxis and/or treatment against Anthrax Class A bioterrorism toxins

    Environmentally assisted cracking in light water reactors. Semiannual report, July 1998-December 1998.

    Get PDF
    This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors from July 1998 to December 1998. Topics that have been investigated include (a) environmental effects on fatigue S-N behavior of primary pressure boundary materials, (b) irradiation-assisted stress corrosion cracking of austenitic stainless steels (SSs), and (c) EAC of Alloys 600 and 690. Fatigue tests have been conducted to determine the crack initiation and crack growth characteristics of austenitic SSs in LWR environments. Procedures are presented for incorporating the effects of reactor coolant environments on the fatigue life of pressure vessel and piping steels. Slow-strain-rate tensile tests and posttest fractographic analyses were conducted on several model SS alloys irradiated to {approx}0.3 and 0.9 x 10{sup 21} n {center_dot} cm{sup -2} (E > 1 MeV) in helium at 289 C in the Halden reactor. The results have been used to determine the influence of alloying and impurity elements on the susceptibility of these steels to irradiation-assisted stress corrosion cracking. Fracture toughness J-R curve tests were also conducted on two heats of Type 304 SS that were irradiated to {approx}0.3 x 10{sup 21} n {center_dot} cm{sup -2} in the Halden reactor. Crack-growth-rate tests have been conducted on compact-tension specimens of Alloys 600 and 690 under constant load to evaluate the resistance of these alloys to stress corrosion cracking in LWR environments
    corecore