951 research outputs found

    Automatic Segmentation of Posterior Pole Retinal Layers In Patients with Early Stage Glaucoma Using Spectral Domain Optical Coherence Tomography

    Get PDF
    Purpose: To measure Ganglion Cell Layer (GCL) and Retinal Nerve Fiber Layer (RNFL) thickness of the retinal posterior pole in patients with early stage primary open-angle glaucoma (POAG) using the new automatic segmentation technology of spectral domain optical coherence tomograph (SD-OCT). Methods: 37 clinical records of patients with early glaucoma (grade 1 to 2 according to the Glaucoma Staging System 2) and 40 age and sex-matched controls were considered in this case-control observational retrospective study. Automated segmentation of GCL and RNFL was performed in one randomly selected eye from the electronic OCT records of each participant using the new Spectralis SD-OCT segmentation technology (Heidelberg Engineering, Inc., Heidelberg, Germany). Thickness of different retinal layers was obtained from each Posterior Pole volumetric scan. Measurements of the peripapillary RNFL thickness (pRNFLt) were also obtained and then compared with those of posterior pole RNFL thickness (ppRNFLt). Results: Both GCL and RNFL were significantly thinner at the retinal posterior pole in the POAG group as compared to the control group (p<0,0001). Furthermore, pRNFLt was significantly thinner in the glaucoma group as opposed to the control group (p<0,0001). Measurements of pRNFLt were significantly correlated with those of the ppRNFLt (Pearson’s coefficient r=0.863). Conclusions: The new Spectralis SD-OCT automatic segmentation tool may be useful in evaluating structural damage in patients with early glaucoma, by providing complementary measurements to the clinical assessment of glaucoma that could be used in conjunction with other relevant parameters in the diagnosis and the evaluation of the progression of the disease

    Bats Use Magnetite to Detect the Earth's Magnetic Field

    Get PDF
    While the role of magnetic cues for compass orientation has been confirmed in numerous animals, the mechanism of detection is still debated. Two hypotheses have been proposed, one based on a light dependent mechanism, apparently used by birds and another based on a “compass organelle” containing the iron oxide particles magnetite (Fe3O4). Bats have recently been shown to use magnetic cues for compass orientation but the method by which they detect the Earth's magnetic field remains unknown. Here we use the classic “Kalmijn-Blakemore” pulse re-magnetization experiment, whereby the polarity of cellular magnetite is reversed. The results demonstrate that the big brown bat Eptesicus fuscus uses single domain magnetite to detect the Earths magnetic field and the response indicates a polarity based receptor. Polarity detection is a prerequisite for the use of magnetite as a compass and suggests that big brown bats use magnetite to detect the magnetic field as a compass. Our results indicate the possibility that sensory cells in bats contain freely rotating magnetite particles, which appears not to be the case in birds. It is crucial that the ultrastructure of the magnetite containing magnetoreceptors is described for our understanding of magnetoreception in animals

    Risk assessment for the spread of Serratia marcescens within dental-unit waterline systems using Vermamoeba vermiformis

    Get PDF
    Vermamoeba vermiformis is associated with the biofilm ecology of dental-unit waterlines (DUWLs). This study investigated whether V. vermiformis is able to act as a vector for potentially pathogenic bacteria and so aid their dispersal within DUWL systems. Clinical dental water was initially examined for Legionella species by inoculating it onto Legionella selective-medium plates. The molecular identity/profile of the glassy colonies obtained indicated none of these isolates were Legionella species. During this work bacterial colonies were identified as a non-pigmented Serratia marcescens. As the water was from a clinical DUWL which had been treated with Alpronℱ this prompted the question as to whether S. marcescens had developed resistance to the biocide. Exposure to Alpronℱ indicated that this dental biocide was effective, under laboratory conditions, against S. marcescens at up to 1x108 colony forming units/millilitre (cfu/ml). V. vermiformis was cultured for eight weeks on cells of S. marcescens and Escherichia coli. Subsequent electron microscopy showed that V. vermiformis grew equally well on S. marcescens and E. coli (p = 0.0001). Failure to detect the presence of S. marcescens within the encysted amoebae suggests that V. vermiformis is unlikely to act as a vector supporting the growth of this newly isolated, nosocomial bacterium

    Design of the Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial to assess the clinical value of the remote pacemaker interrogation in the management of pacemaker patients

    Get PDF
    Abstract Background Although pacemakers are primarily used for the treatment of bradycardia, diagnostic data available in current pacemakers allow them to be also used as sophisticated, continuous monitoring devices. Easy access to these stored data may assist clinicians in making diagnostic and therapeutic decisions sooner, thus avoiding potential long-term sequelae due to untreated clinical disorders. Internet-based remote device interrogation systems provide clinicians with frequent and complete access to stored data in pacemakers. In addition to monitoring device function, remote monitors may be a helpful tool in assisting physicians in the management of common arrhythmia disorders. Methods The Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial is a prospective, randomized, parallel, unblinded, multicenter, open label clinical trial to determine the utility of remote pacemaker interrogation in the earlier diagnosis of clinically actionable events compared to the existing practice of transtelephonic monitoring. There have been 980 patients enrolled and randomized to receive pacemaker follow up with either remote interrogation using the Medtronic CareLinkÂź Network (CareLink) versus the conventional method of transtelephonic monitoring (TTM) in addition to periodic in-person interrogation and programming evaluations. The purpose of this manuscript is to describe the design of the PREFER trial. The results, to be presented separately, will characterize the number of clinically actionable events as a result of pacemaker follow-up using remote interrogation instead of TTM. Trial registration ClinicalTrials.gov: NCT00294645.http://deepblue.lib.umich.edu/bitstream/2027.42/112561/1/13063_2008_Article_231.pd

    Exoplanet Atmosphere Measurements from Transmission Spectroscopy and other Planet-Star Combined Light Observations

    Full text link
    It is possible to learn a great deal about exoplanet atmospheres even when we cannot spatially resolve the planets from their host stars. In this chapter, we overview the basic techniques used to characterize transiting exoplanets - transmission spectroscopy, emission and reflection spectroscopy, and full-orbit phase curve observations. We discuss practical considerations, including current and future observing facilities and best practices for measuring precise spectra. We also highlight major observational results on the chemistry, climate, and cloud properties of exoplanets.Comment: Accepted review chapter; Handbook of Exoplanets, eds. Hans J. Deeg and Juan Antonio Belmonte (Springer-Verlag). 22 pages, 6 figure

    A multicentre phase II study of cisplatin and gemcitabine for malignant mesothelioma

    Get PDF
    Our previous phase II study of cisplatin and gemcitabine in malignant mesothelioma showed a 47.6% (95% CI 26.2–69.0%) response rate with symptom improvement in responding patients. Here we confirm these findings in a multicentre setting, and assess the effect of this treatment on quality of life and pulmonary function. Fifty-three patients with pleural malignant mesothelioma received cisplatin 100 mg m−2 i.v. day 1 and gemcitabine 1000 mg m−2 i.v. days 1, 8, and 15 of a 28 day cycle for a maximum of six cycles. Quality of life and pulmonary function were assessed at each cycle. The best response achieved in 52 assessable patients was: partial response, 17 (33%, 95% CI 20–46%); stable disease, 31 (60%); and progressive disease, four (8%). The median time to disease progression was 6.4 months, median survival from start of treatment 11.2 months, and median survival from diagnosis 17.3 months. Vital capacity and global quality of life remained stable in all patients and improved significantly in responding patients. Major toxicities were haematological, limiting the mean relative dose intensity of gemcitabine to 75%. This schedule of cisplatin and gemcitabine is active in malignant mesothelioma in a multicentre setting. Investigation of alternative scheduling is needed to decrease haematological toxicity and increase the relative dose intensity of gemcitabine whilst maintaining response rate and quality of life

    Circumstellar disks and planets. Science cases for next-generation optical/infrared long-baseline interferometers

    Full text link
    We present a review of the interplay between the evolution of circumstellar disks and the formation of planets, both from the perspective of theoretical models and dedicated observations. Based on this, we identify and discuss fundamental questions concerning the formation and evolution of circumstellar disks and planets which can be addressed in the near future with optical and infrared long-baseline interferometers. Furthermore, the importance of complementary observations with long-baseline (sub)millimeter interferometers and high-sensitivity infrared observatories is outlined.Comment: 83 pages; Accepted for publication in "Astronomy and Astrophysics Review"; The final publication is available at http://www.springerlink.co
    • 

    corecore