706 research outputs found

    Natural organic matter in sedimentary basins and its relation to arsenic in anoxic ground water: the example of West Bengal and its worldwide implications

    Get PDF
    In order to investigate the mechanism of As release to anoxic ground water in alluvial aquifers, the authors sampled ground waters from 3 piezometer nests, 79 shallow (80 m) wells, in an area 750 m by 450 m, just north of Barasat, near Kolkata (Calcutta), in southern West Bengal. High concentrations of As (200-1180 mug L-1) are accompanied by high concentrations of Fe (3-13.7 mgL(-1)) and PO4 (1-6.5 mg L-1). Ground water that is rich in Mn (1-5.3 mg L-1) contains <50 mug L-1 of As. The composition of shallow ground water varies at the 100-m scale laterally and the metre-scale vertically, with vertical gradients in As concentration reaching 200 mug L-1 m(-1). The As is supplied by reductive dissolution of FeOOH and release of the sorbed As to solution. The process is driven by natural organic matter in peaty strata both within the aquifer sands and in the overlying confining unit. In well waters, thermotolerant coliforms, a proxy for faecal contamination, are not present in high numbers (<10 cfu/100 ml in 85% of wells) showing that faecally-derived organic matter does not enter the aquifer, does not drive reduction of FeOOH, and so does not release As to ground water.Arsenic concentrations are high (much greater than50 mug L-1) where reduction of FeOOH is complete and its entire load of sorbed As is released to solution, at which point the aquifer sediments become grey in colour as FeOOH vanishes. Where reduction is incomplete, the sediments are brown in colour and resorption of As to residual FeOOH keeps As concentrations below 10 mug L-1 in the presence of dissolved Fe. Sorbed As released by reduction of Mn oxides does not increase As in ground water because the As resorbs to FeOOH. High concentrations of As are common in alluvial aquifers of the Bengal Basin arise because Himalayan erosion supplies immature sediments, with low surface-loadings of FeOOH on mineral grains, to a depositional environment that is rich in organic mater so that complete reduction of FeOOH is common. (C) 2004 Published by Elsevier Ltd

    Mathematical modelling predicts the spatial distribution of metabolism in skin

    Get PDF

    How did we get here; a historical and social exploration of the construction of English FA coach education

    Get PDF
    Formal coach education, such as courses experienced by coaches, is part of a wider education system, constructed by policy developers, course designers and coach educators. To date, research has explored the complex micro-pedagogical interactions between coach educators and coaches on courses, yet there is little understanding of the historical and social influences on the development of these systems. In response, this study analyses the social construction of The English FA’s coach education system over 50 years (1967–2019). Specifically, this study aimed to (1) identify ‘social architects’ who influenced the development of FA coach education and (2) analyse the wider social, economic, and political influences on these architects and their development of FA coach education over time. To do so, this work re-examines data from 16 semi-structured interviews (with participants who have held significant roles within The FA e.g. Head of Coaching) and 47 policy documents (e.g. course materials). Through a deductive crystallisation process the findings recognise (1) the military’s influence in positioning the coach educator as powerful, (2) how insights from PE and education have informed FA coach education development and (3) how economic opportunities from the 1990s and onward prompted an expansion of FA coach education provision. This important contribution provides a platform for further research to explore the historical social construction of coach education systems

    Constructing Dirac linear fermions in terms of non-linear Heisenberg spinors

    Get PDF
    We show that the massive (or massless) neutrinos can be described as special states of Heisenberg nonlinear spinors. As a by-product of this decomposition a particularly attractive consequence appears: the possibility of relating the existence of only three species of mass-less neutrinos to such internal non-linear structure. At the same time it allows the possibility that neutrino oscillation can occurs even for massless neutrinos

    Monolithically integrated heterodyne optical phase-lock loop with RF XOR phase detector

    Get PDF
    We present results for an heterodyne optical phase-lock loop (OPLL), monolithically integrated on InP with external phase detector and loop filter, which phase locks the integrated laser to an external source, for offset frequencies tuneable between 0.6 GHz and 6.1 GHz. The integrated semiconductor laser emits at 1553 nm with 1.1 MHz linewidth, while the external laser has a linewidth less than 150 kHz. To achieve high quality phase locking with lasers of these linewidths, the loop delay has been made less than 1.8 ns. Monolithic integration reduces the optical path delay between the laser and photodiode to less than 20 ps. The electronic part of the OPLL was implemented using a custom-designed feedback circuit with a propagation delay of similar to 1 ns and an open-loop bandwidth greater than 1 GHz. The heterodyne signal between the locked slave laser and master laser has phase noise below. 90 dBc/Hz for frequency offsets greater than 20 kHz and a phase error variance in 10 GHz bandwidth of 0.04 rad(2). (C) 2011 Optical Society of Americ

    Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives.</p> <p>Methods</p> <p>A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC) corrected for verification bias varying both the rate and mechanism of verification.</p> <p>Results</p> <p>In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5<sup>th </sup>– 97.5<sup>th </sup>centile range constituted as much as 60% of the possible range of AUCs for some simulations.</p> <p>Conclusion</p> <p>Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.</p

    A pragmatic harm reduction approach to manage a large outbreak of wound botulism in people who inject drugs, Scotland 2015

    Get PDF
    Abstract Background People who inject drugs (PWID) are at an increased risk of wound botulism, a potentially fatal acute paralytic illness. During the first 6 months of 2015, a large outbreak of wound botulism was confirmed among PWID in Scotland, which resulted in the largest outbreak in Europe to date. Methods A multidisciplinary Incident Management Team (IMT) was convened to conduct an outbreak investigation, which consisted of enhanced surveillance of cases in order to characterise risk factors and identify potential sources of infection. Results Between the 24th of December 2014 and the 30th of May 2015, a total of 40 cases were reported across six regions in Scotland. The majority of the cases were male, over 30 and residents in Glasgow. All epidemiological evidence suggested a contaminated batch of heroin or cutting agent as the source of the outbreak. There are significant challenges associated with managing an outbreak among PWID, given their vulnerability and complex addiction needs. Thus, a pragmatic harm reduction approach was adopted which focused on reducing the risk of infection for those who continued to inject and limited consequences for those who got infected. Conclusions The management of this outbreak highlighted the importance and need for pragmatic harm reduction interventions which support the addiction needs of PWID during an outbreak of spore-forming bacteria. Given the scale of this outbreak, the experimental learning gained during this and similar outbreaks involving spore-forming bacteria in the UK was collated into national guidance to improve the management and investigation of future outbreaks among PWID

    Inter-hemispheric EEG coherence analysis in Parkinson's disease : Assessing brain activity during emotion processing

    Get PDF
    Parkinson’s disease (PD) is not only characterized by its prominent motor symptoms but also associated with disturbances in cognitive and emotional functioning. The objective of the present study was to investigate the influence of emotion processing on inter-hemispheric electroencephalography (EEG) coherence in PD. Multimodal emotional stimuli (happiness, sadness, fear, anger, surprise, and disgust) were presented to 20 PD patients and 30 age-, education level-, and gender-matched healthy controls (HC) while EEG was recorded. Inter-hemispheric coherence was computed from seven homologous EEG electrode pairs (AF3–AF4, F7–F8, F3–F4, FC5–FC6, T7–T8, P7–P8, and O1–O2) for delta, theta, alpha, beta, and gamma frequency bands. In addition, subjective ratings were obtained for a representative of emotional stimuli. Interhemispherically, PD patients showed significantly lower coherence in theta, alpha, beta, and gamma frequency bands than HC during emotion processing. No significant changes were found in the delta frequency band coherence. We also found that PD patients were more impaired in recognizing negative emotions (sadness, fear, anger, and disgust) than relatively positive emotions (happiness and surprise). Behaviorally, PD patients did not show impairment in emotion recognition as measured by subjective ratings. These findings suggest that PD patients may have an impairment of inter-hemispheric functional connectivity (i.e., a decline in cortical connectivity) during emotion processing. This study may increase the awareness of EEG emotional response studies in clinical practice to uncover potential neurophysiologic abnormalities

    Development and validation of a physical activity monitor for use on a wheelchair

    Get PDF
    Study design: Keeping physically active is important for people who mobilize using a wheelchair. However, current tools to measure physical activity in the wheelchair are either not validated or limited in their application. The purpose of this study was to develop and validate a monitoring system to measure wheelchair movement.&lt;p&gt;&lt;/p&gt; Methods: The system developed consisted of a tri-axial accelerometer placed on the wheel of a wheelchair and an analysis algorithm to interpret the acceleration signals. The two accelerometer outputs in the plane of the wheel were used to calculate the angle of the wheel. From this, outcome measures of wheel revolutions, absolute angle and duration of movement were derived and the direction of movement (forwards or backwards) could be distinguished. Concurrent validity was assessed in comparison with video analysis in 14 people with spinal cord injury using their wheelchair on an indoor track and outdoor wheelchair skills course. Validity was assessed using intraclass correlation coefficients (ICC(2,1)) and Bland–Altman plots.&lt;p&gt;&lt;/p&gt; Results: The monitoring system demonstrated excellent validity for wheel revolutions, absolute angle and duration of movement (ICC(2,1)&#62;0.999, 0.999, 0.981, respectively) in both manual and powered wheelchairs, when the wheelchair was propelled forwards and backwards, and for movements of various durations.&lt;p&gt;&lt;/p&gt; Conclusion: This study has found this monitoring system to be an accurate and objective tool for measuring detailed information on wheelchair movement and manoeuvring regardless of the propulsion technique, direction and speed
    • …
    corecore