108 research outputs found

    Cardiorespiratory and perceptual responses to self-regulated and imposed submaximal arm-leg ergometry

    Get PDF
    Purpose: This study compared cardiorespiratory and perceptual responses to exercise using self-regulated and imposed power outputs distributed between the arms and legs. Methods Ten males (age 21.7 ± 3.4 years) initially undertook incremental arm-crank ergometry (ACE) and cycle ergometry (CYC) tests to volitional exhaustion to determine peak power output (Wpeak). Two subsequent tests involved 20-min combined arm–leg ergometry (ALE) trials, using imposed and self-regulated protocols, both of which aimed to elicit an exercising heart rate of 160 beats min−1. During the imposed trial, arm and leg intensity were set at 40% of each ergometer-specific Wpeak. During the self-regulated trial, participants were asked to self-regulate cadence and resistance to achieve the target heart rate. Heart rate (HR), oxygen uptake (V˙O2 ), pulmonary ventilation (V˙E ), and ratings of perceived exertion (RPE) were recorded continuously. Results As expected, there were no differences between imposed and self-regulated trials for HR, V˙O2 , and V˙E (all P ≥ 0.05). However, central RPE and local RPE for the arms were lower during self-regulated compared imposed trials (P ≤ 0.05). Lower RPE during the self-regulated trial was related to preferential adjustments in how the arms (33 ± 5% Wpeak) and legs (46 ± 5% Wpeak) contributed to the exercise intensity. Conclusions: This study demonstrates that despite similar metabolic and cardiovascular strain elicited by imposed and self-regulated ALE, the latter was perceived to be less strenuous, which is related to participants doing more work with the legs and less work with the arms to achieve the target intensity

    Exercise capacity in children with isolated congenital complete atrioventricular block: does pacing make a difference?

    Get PDF
    Item does not contain fulltextThe management of patients with isolated congenital complete atrioventricular block (CCAVB) has changed during the last decades. The current policy is to pace the majority of patients based on a variety of criteria, among which is limited exercise capacity. Data regarding exercise capacity in this population stems from previous publications reporting small case series of unpaced patients. Therefore, we have investigated the exercise capacity of a group of contemporary children with CCAVB. Sixteen children (mean age 11.5 +/- 4; seven boys, nine girls) with CCAVB were tested. In 13 patients, a median number of three pacemakers were implanted, whereas in three patients no pacemaker was given. All patients had an echocardiogram and completed a cardiopulmonary cycle exercise test. Exercise parameters were determined and compared with reference values obtained from healthy Dutch peers. The peak oxygen uptake/body mass was reduced to 34.4 +/- 9.5 ml kg(-1) min(-1) (79 +/- 24% of predicted) and the ventilatory threshold was reduced to 52 +/- 17% of peak oxygen uptake (78 +/- 21% of predicted), whereas the peak work load/body mass was 2.8 +/- 0.6 W/kg (91 +/- 24% of predicted), which was similar to controls. Importantly, 25% of the paced patients showed upper rate restriction by the pacemaker. In conclusion, children with CCAVB show a reduced peak oxygen uptake and ventilatory threshold, whereas they show normal peak work rates. This indicates that they generate more energy during exercise from anaerobic energy sources. Paced children with CCAVB do not perform better than unpaced children.1 april 201

    Accelerometer Measured Levels of Moderate-to-Vigorous Intensity Physical Activity and Sedentary Time in Children and Adolescents with Chronic Disease: a Systematic Review and Meta-Analysis

    Get PDF
    Context: Moderate-to-vigorous physical activity (MVPA) and sedentary time (ST) are important for child and adolescent health. Objective: To examine habitual levels of accelerometer measured MVPA and ST in children and adolescents with chronic disease, and how these levels compare with healthy peers. Methods: Data sources: An extensive search was carried out in Medline, Cochrane library, EMBASE, SPORTDiscus and CINAHL from 2000–2017. Study selection: Studies with accelerometer-measured MVPA and/or ST (at least 3 days and 6 hours/day to provide estimates of habitual levels) in children 0–19 years of age with chronic diseases but without co-morbidities that would present major impediments to physical activity. In all cases patients were studied while well and clinically stable. Results: Out of 1592 records, 25 studies were eligible, in four chronic disease categories: cardiovascular disease (7 studies), respiratory disease (7 studies), diabetes (8 studies), and malignancy (3 studies). Patient MVPA was generally below the recommended 60 min/day and ST generally high regardless of the disease condition. Comparison with healthy controls suggested no marked differences in MVPA between controls and patients with cardiovascular disease (1 study, n = 42) and type 1 diabetes (5 studies, n = 400; SMD -0.70, 95% CI -1.89 to 0.48, p = 0.25). In patients with respiratory disease, MVPA was lower in patients than controls (4 studies, n = 470; SMD -0.39, 95% CI -0.80, 0.02, p = 0.06). Meta-analysis indicated significantly lower MVPA in patients with malignancies than in the controls (2 studies, n = 90; SMD -2.2, 95% CI -4.08 to -0.26, p = 0.03). Time spent sedentary was significantly higher in patients in 4/10 studies compared with healthy control groups, significantly lower in 1 study, while 5 studies showed no significant group difference. Conclusions: MVPA in children/adolescents with chronic disease appear to be well below guideline recommendations, although comparable with activity levels of their healthy peers except for children with malignancies. Tailored and disease appropriate intervention strategies may be needed to increase MVPA and reduce ST in children and adolescents with chronic disease
    corecore