368 research outputs found

    ALMA Band 9 upgrade: a feasibility study

    Full text link
    We present the results of a study on the feasibility of upgrading the existing ALMA Band 9 receivers (602-720 GHz). In the current configuration, each receiver is a dual channel heterodyne system capable of detecting orthogonally polarized signals through the use of a wire grid and a compact arrangement of mirrors. The main goals of the study are the upgrade of the mixer architecture from Double-Sideband (DSB) to Sideband-separating (2SB), the extension of the IF and RF bandwidth, and the analysis of the possibilities of improving the polarimetric performance. We demonstrate the performance of 2SB mixers both in the lab and on-sky with the SEPIA660 receiver at APEX, which shows image rejection ratios exceeding 20 dB and can perform successful observations of several spectral lines close to the band edges. The same architecture in ALMA Band 9 would lead to an increase in the effective spectral sensitivity and a gain of a factor two in observation time. We set up also an electromagnetic model of the optics to simulate the polarization performance of the receivers, which is currently limited by the cross-polar level and the beam squint, i.e. pointing mismatch between the two polarizations. We present the results of the simulations compared to the measurements and we conclude that the use of a polarizing grid is the main responsible of the limitations.Comment: to appear in Proc. of the mm Universe 2023 conference, Grenoble (France), June 2023, published by F. Mayet et al. (Eds), EPJ Web of conferences, EDP Science

    Interpretation of uniocular and binocular trials of glaucoma medications: an observational case series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To predict the effectiveness of topical glaucoma medications based on initial uniocular and binocular treatment. To test a traditional hypothesis that effectiveness following a uniocular trial is associated with the change in IOP in the initially treated eye minus the change in the initially untreated eye. To determine whether uniocular or binocular treatment trials are superior.</p> <p>Methods</p> <p>Based on a review of medical records, we identified 168 instances in 154 patients with bilateral primary open angle glaucoma of initial uniocular use of a topical glaucoma medication with well-documented intraocular pressure (IOP) readings at baseline (IOP<sub>A</sub>), during the trial (IOP<sub>B</sub>), and at follow-up (IOP<sub>C</sub>). Abstracted data included demographic data, IOP, and medication use. Predictors of the IOP following the trial (IOP<sub>C</sub>) in each eye were identified by multivariable linear regression. In 70 cases, the predictive ability of initial uniocular and binocular treatment could be directly compared.</p> <p>Results</p> <p>In a multivariable analysis, the follow-up pressure in the initially treated eye (IOP<sub>1C</sub>) was directly correlated with treated eye IOP during initial uniocular use (IOP<sub>1B</sub>, p < 0.001). In a multivariable analysis, the follow-up pressure in the initially untreated eye (IOP<sub>2C</sub>) was directly correlated with its baseline IOP<sub>2A </sub>(p < 0.001), and also tended to be associated with treated IOP<sub>1B </sub>(p = 0.07). The multivariable regression coefficient (b) for the IOP change in the initially untreated eye was generally not close to the value of -1 expected by the classic teaching (for eye 1, b = 0.04, p = 0.35; for eye 2, b = 0.07, p = 0.50). In 70 cases, the uniocular and binocular trials predicted a similar fraction of the variance in follow-up IOP<sub>1C </sub>(r<sup>2 </sup>= 0.56 and 0.57, respectively) and IOP<sub>2C </sub>(r<sup>2 </sup>= 0.39 and 0.38, respectively).</p> <p>Conclusion</p> <p>1) For uniocular trials, the IOP change in the untreated eye should not be subtracted from that in the treated eye. 2) Uniocular and binocular trials have similar predictive value when interpreted correctly. Either may be selected based on clinical circumstances.</p

    Excess path delays from sentinel interferometry to improve weather forecasts

    Get PDF
    A synthetic aperture radar can offer not only an accurate monitoring of the earth surface deformation, but also information on the troposphere, such as the total path delay or the columnar water vapor at high horizontal resolution. This can be achieved by proper interferometric processing and postprocessing of the radar interferograms. The fine and unprecedented horizontal resolution of the tropospheric products can offer otherwise unattainable information to be assimilated into numerical weather prediction models, which are progressively increasing their resolving capabilities. A number of tricks on the most effective processing approaches, as well as a novel method to pass from multipass differential interferometry products to absolute tropospheric columnar quantities are discussed. The proposed products and methods are assessed using real Sentinel-1 data. The experiment aims at evaluating the accuracy of the derived information and its impact on the weather prediction skill for two meteorological events in Italy. The main perspective of the study is linked to the possibility of exploiting interferometric products from a geosynchronous platform, thus complementing the inherent high resolution of SAR sensors with the required frequent revisit needed for meteorological applications

    The p53 codon 72 PRO/PRO genotype may be associated with initial central visual field defects in Caucasians with primary open angle glaucoma

    Get PDF
    Background: Loss of vision in glaucoma is due to apoptotic retinal ganglion cell loss. While p53 modulates apoptosis, gene association studies between p53 variants and glaucoma have been inconsistent. In this study we evaluate the association between a p53 variant functionally known to influence apoptosis (codon 72 Pro/Arg) and the subset of primary open angle glaucoma (POAG) patients with early loss of central visual field. Methods: Genotypes for the p53 codon 72 polymorphism (Pro/Arg) were obtained for 264 POAG patients and 400 controls from the U.S. and in replication studies for 308 POAG patients and 178 controls from Australia (GIST). The glaucoma patients were divided into two groups according to location of initial visual field defect (either paracentral or peripheral). All cases and controls were Caucasian with European ancestry. Results: The p53-PRO/PRO genotype was more frequent in the U.S. POAG patients with early visual field defects in the paracentral regions compared with those in the peripheral regions or control group (p = 2.761025). We replicated this finding in the GIST cohort (p = 7.361023, and in the pooled sample (p = 6.661027) and in a meta-analysis of both the US and GIST datasets (1.361026, OR 2.17 (1.58–2.98 for the PRO allele). Conclusions: These results suggest that the p53 codon 72 PRO/PRO genotype is potentially associated with early paracentral visual field defects in primary open-angle glaucoma patients.NHMRC: This study was supported by National Institutes of Health/National Eye Institute grants: R01EY015872 (Wiggs), R01EY015473 (Pasquale), P30EY014104 (Wiggs), Research to Prevent Blindness (Wiggs, Pasquale, Realini), the Harvard Glaucoma Center of Excellence (Wiggs, Pasquale), The Massachusetts Lions Eye Research Fund (Wiggs, Pasquale), National Health & Medical Research Council Project grant 229960, the Ophthalmic Research Institute of Australia, and Glaucoma Australia. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    The impact of global navigation satellite system (GNSS) zenith total delay data assimilation on the short-term precipitable water vapor and precipitation forecast over Italy using the Weather Research and Forecasting (WRF) model

    Get PDF
    The impact of assimilating GNSS-ZTD (global navigation satellite system–zenith total delay) on the precipitable water vapor and precipitation forecast over Italy is studied for the month of October 2019, which was characterized by several moderate to intense precipitation events, especially over northwestern Italy. The WRF (Weather Research and Forecasting) model, version 4.1.3, is used with its 3D-Var data assimilation system to assimilate ZTD observations from 388 GNSS receivers distributed over the country. The dataset was built collecting data from all the major national and regional GNSS permanent networks, achieving dense coverage over the whole area. The water vapor forecast is verified for the forecast hours of 1–6 h after the last data assimilation time. Results show that WRF underestimates the atmospheric water vapor content for the period, and GNSS-ZTD data assimilation improves this underestimation. The precipitation forecast is verified in the phases of 0–3 and 3–6 h after the last data assimilation time using more than 3000 rain gauges spread over Italy. The application of GNSS-ZTD data assimilation to a case study improved the precipitation forecast by increasing the rainfall maximum and by better focusing the precipitation pattern over northeastern Italy, with the main drawback being the prediction of false alarms. Considering the study over the whole period, GNSS-ZTD data assimilation had a positive impact on rainfall forecast, with an improvement in the performance up to 6 h and with statistically significant results for moderate to intense rainfall thresholds (25–30 mm (3 h)−1).</p

    The optical design of the Litebird middle and high frequency telescope

    Get PDF
    LiteBIRD is a JAXA strategic L-class mission devoted to the measurement of polarization of the Cosmic Microwave Background, searching for the signature of primordial gravitational waves in the B-modes pattern of the polarization. The onboard instrumentation includes a Middle and High Frequency Telescope (MHFT), based on a pair of cryogenically cooled refractive telescopes covering, respectively, the 89-224 GHz and the 166-448 GHz bands. Given the high target sensitivity and the careful systematics control needed to achieve the scientific goals of the mission, optical modeling and characterization are performed with the aim to capture most of the physical effects potentially affecting the real performance of the two refractors. We describe the main features of the MHFT, its design drivers and the major challenges in system optimization and characterization. We provide the current status of the development of the optical system and we describe the current plan of activities related to optical performance simulation and validation
    • …
    corecore