1,139 research outputs found

    Preliminary Monte Carlo simulations of linear accelerators in Time-of-Flight Compton Scatter imaging for cargo security

    Get PDF
    The economic impact of illicit trade is in the trillions of dollars per year, with a proportion of this trade concealed within cargo containers. The interdiction of this trade relies upon efficient and effective external screening of cargo containers, typically using x rays. The present work introduces a technique of x-ray screening that aims to increase the efficiency and effectiveness of x-ray screening. Traditional X-ray screening of cargo containers is performed using high-energy (MV) transmission imaging or low-energy (kV) Compton scatter imaging to provide two-dimensional images. Two-dimensional images can contain complex, overlapping objects and require significant experience and time to interpret. Time-of-Flight information can be used in conjunction with Compton scatter imaging to provide information about the depth of each Compton scatter interaction, leading to three-dimensional images, reducing false positives and image analysis time. The expected Time-of-Flight from photons scattered back from a set of objects is well defined when the photons are produced with a delta-type (infinitely narrow) pulse duration, however, commercially available linear accelerators used for cargo screening typically have pulse widths of the order of 1 μs. In the present work, the possible use of linear accelerators for Time-of-Flight Compton scatter imaging is investigated using a mixture of analytic and Monte Carlo methods. Ideal data are obtained by convolving a number of wide x-ray pulses (up to 5 μs) with the expected Time-of-Flight from a set of objects using a delta-type pulse. Monte Carlo simulations, using Geant4, have been performed to generate x-ray spectra produced by a linear accelerator. The spectra are then used as the input for detailed Monte Carlo simulations of the Time-of-Flight of photons produced by a single linear accelerator pulse scattering back from a set of objects. Both ideal and Monte Carlo data suggest that Time-of-Flight information can be recovered from a wide linear accelerator pulse, provided that the leading and falling edge of the pulse are sharp. In addition, it has been found that using a linear accelerator leads to double the amount of Time-of-Flight information as both the leading and falling edge are utilised (unlike for a delta-type pulse)

    Hybrid Angular- and Energy-Dispersive X-ray Diffraction Computed Tomography

    Get PDF
    X-ray diffraction is a material-specific technique, the results of which can be used as a material fingerprint to identify unknowns. In this paper we present an adaptation to a novel hybrid angular- and energy-dispersive X-ray diffraction technique, which, until now, has been limited in utility by sample thickness. Computed tomography techniques have been applied to spatially resolve the origin of the scattering signals and to reconstruct the diffraction pattern in each pixel. 2D cross-correlation has been used to compare the reconstructed data to a library of standards as a means of identifying the material present

    Scallop swimming kinematics and muscle performance: modelling the effects of "within-animal" variation in temperature sensitivity

    Get PDF
    Escape behaviour was investigated in Queen scallops (Aequipecten opercularis) acclimated to 5, 10 or 15 degrees C and tested at their acclimation temperature. Scallops are active molluscs, able to escape from predators by jet-propelled swimming using a striated muscle working in opposition to an elastic hinge ligament. The first cycle of the escape response was recorded using high-speed video ( 250 Hz) and whole-animal velocity and acceleration determined. Muscle shortening velocity, force and power output were calculated using measurements of valve movement and jet area, and a simple biomechanical model. The average shortening speed of the adductor muscle had a Q(10) of 2.04, significantly reducing the duration of the jetting phase of the cycle with increased temperature. Muscle lengthening velocity and the overall duration of the clap cycle were changed little over the range 5 - 15 degrees C, as these parameters were controlled by the relatively temperature-insensitive, hinge ligament. Improvements in the average power output of the adductor muscle over the first clap cycle ( 222 vs. 139 W kg(-1) wet mass at 15 and 5 degrees C respectively) were not translated into proportional increases in overall swimming velocity, which was only 32% higher at 15 degrees C ( 0.37m s(-1)) than 5 degrees C (0.28 m s(-1))

    Preliminary results of a feasibility study of the use of information technology for identification of suspected colorectal cancer in primary care: the CREDIBLE study

    Get PDF
    This is the final version of the article. Available from Cancer Research UK/Nature Publishing Group via the DOI in this record.BACKGROUND: We report the findings of a feasibility study using information technology to search electronic primary care records and to identify patients with possible colorectal cancer. METHODS: An algorithm to flag up patients meeting National Institute for Health and Care Excellence (NICE) urgent referral criteria for suspected colorectal cancer was developed and incorporated into clinical audit software. This periodically flagged up such patients aged 60 to 79 years. General practitioners (GPs) reviewed flagged-up patients and decided on further clinical management. We report the numbers of patients identified and the numbers that GPs judged to need further review, investigations or referral to secondary care and the final diagnoses. RESULTS: Between January 2012 and March 2014, 19,580 records of patients aged 60 to 79 years were searched in 20 UK general practices, flagging up 809 patients who met urgent referral criteria. The majority of the patients had microcytic anaemia (236 (29%)) or rectal bleeding (205 (25%)). A total of 274 (34%) patients needed further clinical review of their records; 199 (73%) of these were invited for GP consultation, and 116 attended, of whom 42 were referred to secondary care. Colon cancer was diagnosed in 10 out of 809 (1.2%) flagged-up patients and polyps in a further 28 out of 809 (3.5%). CONCLUSIONS: It is technically possible to identify patients with colorectal cancer by searching electronic patient records.We acknowledge the General Practitioners, practice nurses, practice managers and administrative staff who supported this study, our trial co-ordinator Marie Crook, Anthony Ingold who was one of our patient representatives and MSDi for their support in developing the software algorithm. We also acknowledge the support of the National Institute for Health Research Clinical Research Network. This study was funded by the National Awareness and Early Diagnosis Initiative (NAEDI). TM is partly funded by the National Institute for Health Research (NIHR) through the Collaborations for Leadership in Applied Health Research and Care for the West Midlands (CLAHRC-WM) programme

    Microcrystals coating the wing membranes of a living insect (Psocoptera: Psyllipsocidae) from a Brazilian cave

    Get PDF
    Two specimens of Psyllipsocus yucatan with black wings were found with normal individuals of this species on guano piles produced by the common vampire bat Desmodus rotundus. These specimens have both pairs of wings dorsally and ventrally covered by a black crystalline layer. They did not exhibit any signs of reduced vitality in the field and their morphology is completely normal. This ultrathin (1.5 µm) crystalline layer, naturally deposited on a biological membrane, is documented by photographs, SEM micrographs, energy dispersive spectroscopy (EDS) and X-ray diffractometry (XRD). The crystalline deposit contains iron, carbon and oxygen, but the mineral species could not be identified. Guano probably played a role in its formation; the presence of iron may be a consequence of the excretion of iron by the common vampire bat. This enigmatic phenomenon lacks obvious biological significance but may inspire bionic applications. Nothing similar has ever been observed in terrestrial arthropods

    Quantitative fibronectin to help decision-making in women with symptoms of preterm labour (QUIDS) part 1: Individual participant data meta-analysis and health economic analysis.

    Get PDF
    INTRODUCTION: The aim of the QUIDS study is to develop a decision support tool for the management of women with symptoms and signs of preterm labour, based on a validated prognostic model using quantitative fetal fibronectin (qfFN) concentration, in combination with clinical risk factors. METHODS AND ANALYSIS: The study will evaluate the Rapid fFN 10Q System (Hologic, Marlborough, Massachusetts) which quantifies fFN in a vaginal swab. In part 1 of the study, we will develop and internally validate a prognostic model using an individual participant data (IPD) meta-analysis of existing studies containing women with symptoms of preterm labour alongside fFN measurements and pregnancy outcome. An economic analysis will be undertaken to assess potential cost-effectiveness of the qfFN prognostic model. The primary endpoint will be the ability of the prognostic model to rule out spontaneous preterm birth within 7 days. Six eligible studies were identified by systematic review of the literature and five agreed to provide their IPD (n=5 studies, 1783 women and 139 events of preterm delivery within 7 days of testing). ETHICS AND DISSEMINATION: The study is funded by the National Institute of Healthcare Research Health Technology Assessment (HTA 14/32/01). It has been approved by the West of Scotland Research Ethics Committee (16/WS/0068). PROSPERO REGISTRATION NUMBER: CRD42015027590. VERSION: Protocol version 2, date 1 November 2016

    Study protocol: quantitative fibronectin to help decision-making in women with symptoms of preterm labour (QUIDS) part 2, UK Prospective Cohort Study.

    Get PDF
    INTRODUCTION: The aim of the QUIDS study is to develop a decision support tool for the management of women with symptoms and signs of preterm labour, based on a validated prognostic model using quantitative fetal fibronectin (fFN) concentration, in combination with clinical risk factors. METHODS AND ANALYSIS: The study will evaluate the Rapid fFN 10Q System (Hologic, Marlborough, Massachusetts, USA) which quantifies fFN in a vaginal swab. In QUIDS part 2, we will perform a prospective cohort study in at least eight UK consultant-led maternity units, in women with symptoms of preterm labour at 22+0 to 34+6 weeks gestation to externally validate a prognostic model developed in QUIDS part 1. The effects of quantitative fFN on anxiety will be assessed, and acceptability of the test and prognostic model will be evaluated in a subgroup of women and clinicians (n=30). The sample size is 1600 women (with estimated 96-192 events of preterm delivery within 7 days of testing). Clinicians will be informed of the qualitative fFN result (positive/negative) but be blinded to quantitative fFN result. Research midwives will collect outcome data from the maternal and neonatal clinical records. The final validated prognostic model will be presented as a mobile or web-based application. ETHICS AND DISSEMINATION: The study is funded by the National Institute of Healthcare Research Health Technology Assessment (HTA 14/32/01). It has been approved by the West of Scotland Research Ethics Committee (16/WS/0068). VERSION: Protocol V.2, Date 1 November 2016. TRIAL REGISTRATION NUMBER: ISRCTN 41598423andCPMS: 31277

    Natural killer cells attenuate cytomegalovirus-induced hearing loss in mice

    Get PDF
    <div><p>Congenital cytomegalovirus (CMV) infection is the most common non-hereditary cause of sensorineural hearing loss (SNHL) yet the mechanisms of hearing loss remain obscure. Natural Killer (NK) cells play a critical role in regulating murine CMV infection via NK cell recognition of the Ly49H cell surface receptor of the viral-encoded m157 ligand expressed at the infected cell surface. This Ly49H NK receptor/m157 ligand interaction has been found to mediate host resistance to CMV in the spleen, and lung, but is much less effective in the liver, so it is not known if this interaction is important in the context of SNHL. Using a murine model for CMV-induced labyrinthitis, we have demonstrated that the Ly49H/m157 interaction mediates host resistance in the temporal bone. BALB/c mice, which lack functional Ly49H, inoculated with mCMV at post-natal day 3 developed profound hearing loss and significant outer hair cell loss by 28 days of life. In contrast, C57BL/6 mice, competent for the Ly49H/m157 interaction, had minimal hearing loss and attenuated outer hair cell loss with the same mCMV dose. Administration of Ly49H blocking antibody or inoculation with a mCMV viral strain deleted for the m157 gene rendered the previously resistant C57BL/6 mouse strain susceptible to hearing loss to a similar extent as the BALB/c mouse strain indicating a direct role of the Ly49H/m157 interaction in mCMV-dependent hearing loss. Additionally, NK cell recruitment to sites of infection was evident in the temporal bone of inoculated susceptible mouse strains. These results demonstrate participation of NK cells in protection from CMV-induced labyrinthitis and SNHL in mice.</p></div

    Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review

    Get PDF
    Background: Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. Methods: We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. Results: The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Conclusion: Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation
    corecore