237 research outputs found
On the ratio of consecutive gaps between primes
In the present work we prove a common generalization of Maynard-Tao's recent
result about consecutive bounded gaps between primes and on the
Erd\H{o}s-Rankin bound about large gaps between consecutive primes. The work
answers in a strong form a 60 years old problem of Erd\"os, which asked whether
the ratio of two consecutive primegaps can be infinitely often arbitrarily
small, and arbitrarily large, respectively
Collaborative dynamic decision making: a case study from B2B supplier selection
The problem of supplier selection can be easily modeled as a multiple-criteria decision making (MCDM) problem: businesses express their preferences with respect to suppliers, which can then be ranked and selected. This approach has two major pitfalls: first, it does not consider a dynamic scenario, in which suppliers and their ratings are constantly changing; second, it only addressed the problem from the point of view of a single business, and cannot be easily applied when considering more than one business. To overcome these problems, we introduce a method for supplier selection that builds upon the dynamic MCDM framework of Campanella and Ribeiro [1] and, by means of a linear programming model, can be used in the case of multiple collaborating businesses plan- ning their next batch of orders together.Fundação para a Ciência e a Tecnologia, Portugal, under contract CONT DOUT/49/UNINOVA/0/5902/1/200
Emergency hospital care for adults with suspected seizures in the NHS in England 2007-2013: a cross-sectional study
Aims To quantify the frequency, characteristics, geographical variation and costs of emergency hospital care for suspected seizures.
Design Cross-sectional study using routinely collected data (Hospital Episode Statistics).
Setting The National Health Service in England 2007–2013.
Participants Adults who attended an emergency department (ED) or were admitted to hospital.
Results In England (population 2011: 53.11 million, 41.77 million adults), suspected seizures gave rise to 50 111 unscheduled admissions per year among adults (≥18 years). This is 47.1% of unscheduled admissions for neurological conditions and 0.71% of all unscheduled admissions. Only a small proportion of admissions for suspected seizures were coded as status epilepticus (3.5%) and there were a very small number of dissociative (non-epileptic) seizures. The median length of stay for each admission was 1 day, the median cost for each admission was £1651 (116.2 million) per year. 16.8% of patients had more than one admission per year. There was significant geographical variability in the rate of admissions corrected for population age and gender differences and some areas had rates of admission which were consistently higher than the average.
Conclusions Our data show that suspected seizures are the most common neurological cause of admissions to hospital in England, that readmissions are common and that there is significant geographical variability in admission rates. This variability has not previously been reported in the published literature. The cause of the geographical variation is unknown; important factors are likely to include prevalence, deprivation and clinical practice and these require further investigation. Dissociative seizures are not adequately diagnosed during ED attendances and hospital admissions
Quantification of Myocardial Blood Flow in Absolute Terms Using (82)Rb PET Imaging: The RUBY-10 Study.
OBJECTIVES: The purpose of this study was to compare myocardial blood flow (MBF) and myocardial flow reserve (MFR) estimates from rubidium-82 positron emission tomography ((82)Rb PET) data using 10 software packages (SPs) based on 8 tracer kinetic models.
BACKGROUND: It is unknown how MBF and MFR values from existing SPs agree for (82)Rb PET.
METHODS: Rest and stress (82)Rb PET scans of 48 patients with suspected or known coronary artery disease were analyzed in 10 centers. Each center used 1 of 10 SPs to analyze global and regional MBF using the different kinetic models implemented. Values were considered to agree if they simultaneously had an intraclass correlation coefficient >0.75 and a difference <20% of the median across all programs.
RESULTS: The most common model evaluated was the Ottawa Heart Institute 1-tissue compartment model (OHI-1-TCM). MBF values from 7 of 8 SPs implementing this model agreed best. Values from 2 other models (alternative 1-TCM and Axially distributed) also agreed well, with occasional differences. The MBF results from other models (e.g., 2-TCM and retention) were less in agreement with values from OHI-1-TCM.
CONCLUSIONS: SPs using the most common kinetic model-OHI-1-TCM-provided consistent results in measuring global and regional MBF values, suggesting that they may be used interchangeably to process data acquired with a common imaging protocol
Low-energy cutoffs in electron spectra of solar flares: statistical survey
The Ramaty High Energy Solar Spectroscopic Imager (RHESSI) X-ray data base
(February 2002 -- May 2006) has been searched to find solar flares with weak
thermal components and flat photon spectra. Using a regularised inversion
technique, we determine the mean electron flux distribution from count spectra
of a selection of events with flat photon spectra in the 15--20 keV energy
range. Such spectral behaviour is expected for photon spectra either affected
by photospheric albedo or produced by electron spectra with an absence of
electrons in a given energy range, e.g. a low-energy cutoff in the mean
electron spectra of non-themal particles. We have found 18 cases which exhibit
a statistically significant local minimum (a dip) in the range of 10--20 keV.
The positions and spectral indices of events with low-energy cutoff indicate
that such features are likely to be the result of photospheric albedo. It is
shown that if the isotropic albedo correction was applied, all low-energy
cutoffs in the mean electron spectrum were removed and hence the low energy
cutoffs in the mean electron spectrum of solar flares above 12 keV cannot
be viewed as real features in the electron spectrum. If low-energy cutoffs
exist in the mean electron spectra, the energy of low energy cutoffs should be
less than 12 keV.Comment: 9 pages, 5 figures, submitted to Solar Physic
Differential cross section and recoil polarization measurements for the gamma p to K+ Lambda reaction using CLAS at Jefferson Lab
We present measurements of the differential cross section and Lambda recoil
polarization for the gamma p to K+ Lambda reaction made using the CLAS detector
at Jefferson Lab. These measurements cover the center-of-mass energy range from
1.62 to 2.84 GeV and a wide range of center-of-mass K+ production angles.
Independent analyses were performed using the K+ p pi- and K+ p (missing pi -)
final-state topologies; results from these analyses were found to exhibit good
agreement. These differential cross section measurements show excellent
agreement with previous CLAS and LEPS results and offer increased precision and
a 300 MeV increase in energy coverage. The recoil polarization data agree well
with previous results and offer a large increase in precision and a 500 MeV
extension in energy range. The increased center-of-mass energy range that these
data represent will allow for independent study of non-resonant K+ Lambda
photoproduction mechanisms at all production angles.Comment: 22 pages, 16 figure
A Bayesian analysis of pentaquark signals from CLAS data
We examine the results of two measurements by the CLAS collaboration, one of
which claimed evidence for a pentaquark, whilst the other found no
such evidence. The unique feature of these two experiments was that they were
performed with the same experimental setup. Using a Bayesian analysis we find
that the results of the two experiments are in fact compatible with each other,
but that the first measurement did not contain sufficient information to
determine unambiguously the existence of a . Further, we suggest a
means by which the existence of a new candidate particle can be tested in a
rigorous manner.Comment: 5 pages, 3 figure
Measurement of the nuclear multiplicity ratio for hadronization at CLAS
The influence of cold nuclear matter on lepto-production of hadrons in
semi-inclusive deep inelastic scattering is measured using the CLAS detector in
Hall B at Jefferson Lab and a 5.014 GeV electron beam. We report the
multiplicity ratios for targets of C, Fe, and Pb relative to deuterium as a
function of the fractional virtual photon energy transferred to the
and the transverse momentum squared of the . We find that the
multiplicity ratios for are reduced in the nuclear medium at high
and low , with a trend for the transverse momentum to be
broadened in the nucleus for large .Comment: Submitted to Phys. Lett.
Coherent Photoproduction of pi^+ from 3^He
We have measured the differential cross section for the
He reaction. This reaction was studied using
the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons
produced with the Hall-B bremsstrahlung tagging system in the energy range from
0.50 to 1.55 GeV were incident on a cryogenic liquid He target. The
differential cross sections for the He
reaction were measured as a function of photon-beam energy and pion-scattering
angle. Theoretical predictions to date cannot explain the large cross sections
except at backward angles, showing that additional components must be added to
the model.Comment: 11 pages, 16 figure
- …