143 research outputs found

    Duplicated Palmaris Longus Muscle With Insertion Onto The Transverse Carpal Ligament: A Case Report

    Get PDF
    The palmaris longus muscle is one of the most anatomically variable muscles in the human body, with incidence ranging from 0-63.9%.  While these anatomical variations are typically benign, they are of clinical importance as they can contribute to neurovascular and biomechanical dysfunction.  We report here a duplicated palmaris longus muscle with an insertion onto the transverse carpal ligament found during cadaveric dissection in a graduate anatomy course for physical and occupational therapy students.&nbsp

    A Phytochemical Study of Selected Podostemaceae

    Get PDF
    Podostemum ceratophyllum contains γ-mangostin and its 6-glucoside. The aglycone is also present in Marathrum, Oserya, and Vanroyenella, but is absent from Tristicha. Anthocyanins were identified from all genera, but no additional fiavonoids were detected. Condensed and hydrolyzable tannins, iridoids, cyanogenic glycosides, and alkaloids were lacking in all Podostemaceae examined. Phytochemical constituents do not clarify the uncertain systematic affinity ofPodostemaceae, but emphasize the generally accepted taxonomic isolation of this family

    SMALL-SCALE TESTING OF PLUTONIUM (IV) OXALATE PRECIPITATION AND CALCINATION TO PLUTONIUM OXIDE TO SUPPORT THE MOX FEED MISSION

    Get PDF
    The H-Canyon facility will be used to dissolve Pu metal for subsequent purification and conversion to plutonium dioxide (PuO{sub 2}) using Phase II of HB-Line. To support the new mission, SRNL conducted a series of experiments to produce calcined plutonium (Pu) oxide and measure the physical properties and water adsorption of that material. This data will help define the process operating conditions and material handling steps for HB-Line. An anion exchange column experiment produced 1.4 L of a purified 52.6 g/L Pu solution. Over the next nine weeks, seven Pu(IV) oxalate precipitations were performed using the same stock Pu solution, with precipitator feed acidities ranging from 0.77 M to 3.0 M nitric acid and digestion times ranging from 5 to 30 minutes. Analysis of precipitator filtrate solutions showed Pu losses below 1% for all precipitations. The four larger precipitation batches matched the target oxalic acid addition time of 44 minutes within 4 minutes. The three smaller precipitation batches focused on evaluation of digestion time and the oxalic acid addition step ranged from 25-34 minutes because of pump limitations in the low flow range. Following the precipitations, 22 calcinations were performed in the range of 610-690 C, with the largest number of samples calcined at either 650 or 635 C. Characterization of the resulting PuO{sub 2} batches showed specific surface areas in the range of 5-14 m{sup 2}/g, with 16 of the 22 samples in the range of 5-10 m2/g. For samples analyzed with typical handling (exposed to ambient air for 15-45 minutes with relative humidities of 20-55%), the moisture content as measured by Mass Spectrometry ranged from 0.15 to 0.45 wt % and the total mass loss at 1000 C, as measured by TGA, ranged from 0.21 to 0.58 wt %. For the samples calcined between 635 and 650 C, the moisture content without extended exposure ranged from 0.20 to 0.38 wt %, and the TGA mass loss ranged from 0.26 to 0.46 wt %. Of these latter samples, the samples calcined at 650 C generally had lower specific surface areas and lower moisture contents than the samples calcined at 635 C, which matches expectations from the literature. Taken together, the TGA-MS results for samples handled at nominally 20-50% RH, without extended exposure, indicate that the Pu(IV) oxalate precipitation process followed by calcination at 635-650 C appears capable of producing PuO{sub 2} with moisture content < 0.5 wt% as required by the 3013 Standard. Exposures of PuO{sub 2} samples to ambient air for 3 or more hours generally showed modest mass gains that were primarily gains in moisture content. These results point to the need for a better understanding of the moisture absorption of PuO{sub 2} and serve as a warning that extended exposure times, particularly above the 50% RH level observed in this study will make the production of PuO{sub 2} with less than 0.5 wt % moisture more challenging. Samples analyzed in this study generally contained approximately 2 monolayer equivalents of moisture. In this study, the bulk of the moisture released from samples below 300 C, as did a significant portion of the CO{sub 2}. Samples in this study consistently released a minor amount of NO in the 40-300 C range, but no samples released CO or SO{sub 2}. TGA-MS results also showed that MS moisture content accounted for 80 {+-} 8% of the total mass loss at 1000 C measured by the TGA. The PuO{sub 2} samples produced had particles sizes that typically ranged from 0.2-88 {micro}m, with the mean particle size ranging from 6.4-9.3 {micro}m. The carbon content of ten different calcination batches ranged from 190-480 {micro}g C/g Pu, with an average value of 290 {micro}g C/g Pu. A statistical review of the calcination conditions and resulting SSA values showed that in both cases tested, calcination temperature had a significant effect on SSA, as expected from literature data. The statistical review also showed that batch size had a significant effect on SSA, but the narrow range of batch sizes tested is a compelling reason to set aside that result until tests with larger batch sizes are completed. When feed acidity was not included as a variable, calcination time had a significant effect on SSA. However, including feed acidity as a variable showed that neither feed acidity nor calcination time had a significant effect on SSA in this study. Also, for both cases the statistical review also indicated that digestion time did not have a significant effect on SSA

    Initial Thrust Measurements of Marshall's Ion-ioN Thruster

    Get PDF
    Electronegative ion thrusters are a variation of tradition gridded ion thruster technology differentiated by the production and acceleration of both positive and negative ions. Benefits of electronegative ion thrusters include the elimination of lifetime-limiting cathodes from the thruster architecture and the ability to generate appreciable thrust from both charge species. Following the continued development of electronegative ion thruster technology as exhibited by the PEGASES (Plasma Propulsion with Electronegative GASES) thruster, direct thrust measurements are required to push interest in electronegative ion thruster technology forward. For this work, direct thrust measurements of the MINT (Marshall's Ion-ioN Thruster) will be taken on a hanging pendulum thrust stand for propellant mixtures of Sulfur Hexafluoride and Argon at volumetric flow rates of 5-25 sccm at radio frequency power levels of 100-600 watts at a radio frequency of 13.56 MHz. Acceleration grid operation is operated using a square waveform bias of +/-300 volts at a frequency of 25 kHz

    Bilateral Long Head of the Triceps Brachii Muscle Innervation via Axillary Nerve: A Case Report

    Get PDF
    The radial nerve has traditionally been considered the innervation of the long head of the triceps brachii (LHT). However, cadaveric studies have discovered LHT innervation via the axillary nerve in roughly 6-15 % of shoulders. A cadaver with exclusive axillary nerve innervation to the LHT bilaterally was discovered during cadaveric dissection in a graduate course at Samford University. This anatomical variation may have clinical implications for surgeries, shoulder dislocations, and quadrilateral space syndrome. Axillary nerve injuries may additionally present with shoulder extension and elbow extension weakness if this variation is present.&nbsp

    A Communicating Branch Between the Musculocutaneous Nerve and the Median Nerve: A Case Report

    Get PDF
    Anatomical variations of peripheral nerves are commonly reported in the literature.  While typically benign, they are of clinical importance as they can contribute to atypical clinical presentations, cause difficulty with imaging and nerve conduction studies, and lead to surgical challenges for surgeons.  We report here a communicating branch between the musculocutaneous nerve and median nerve found during cadaveric dissection in a Doctor of Nursing Practice course in the Department of Nurse Anesthesia at Samford University.  Although the case described here is among the most common anatomical variations of the peripheral nerves, there are classification systems for this variation that need to be recognized and applied by anatomists, clinicians, and surgeons
    corecore