164 research outputs found

    Spacecraft materials studies on the Aerospace Corporation tray on EOIM-3

    Get PDF
    A passive tray was flown on the Effects of Oxygen Interaction with Materials experiment on STS-46 (EOIM-3) with 82 samples from The Aerospace Corporation. A variety of advanced materials related to potential uses on future spacecraft were included for evaluation representing optical coatings, lubricants, polymers, composites, carbon-carbon composite protective coatings, graphite protective coatings, thermal-control materials, and some samples of current materials. An overview of the available results from the investigations of these materials is presented

    Mars Earth Return Vehicle (MERV) Propulsion Options

    Get PDF
    The COMPASS Team was tasked with the design of a Mars Sample Return Vehicle. The current Mars sample return mission is a joint National Aeronautics and Space Administration (NASA) and European Space Agency (ESA) mission, with ESA contributing the launch vehicle for the Mars Sample Return Vehicle. The COMPASS Team ran a series of design trades for this Mars sample return vehicle. Four design options were investigated: Chemical Return /solar electric propulsion (SEP) stage outbound, all-SEP, all chemical and chemical with aerobraking. The all-SEP and Chemical with aerobraking were deemed the best choices for comparison. SEP can eliminate both the Earth flyby and the aerobraking maneuver (both considered high risk by the Mars Sample Return Project) required by the chemical propulsion option but also require long low thrust spiral times. However this is offset somewhat by the chemical/aerobrake missions use of an Earth flyby and aerobraking which also take many months. Cost and risk analyses are used to further differentiate the all-SEP and Chemical/Aerobrake options

    Trends in Metal Oxide Stability for Nanorods, Nanotubes, and Surfaces

    Full text link
    The formation energies of nanostructures play an important role in determining their properties, including the catalytic activity. For the case of 15 different rutile and 8 different perovskite metal oxides, we find that the density functional theory (DFT) calculated formation energies of (2,2) nanorods, (3,3) nanotubes, and the (110) and (100) surfaces may be described semi-quantitatively by the fraction of metal--oxygen bonds broken and the bonding band centers in the bulk metal oxide

    Quasiparticle interfacial level alignment of highly hybridized frontier levels: H2_2O on TiO2_2(110)

    Get PDF
    Knowledge of the frontier levels' alignment prior to photo-irradiation is necessary to achieve a complete quantitative description of H2_2O photocatalysis on TiO2_2(110). Although H2_2O on rutile TiO2_2(110) has been thoroughly studied both experimentally and theoretically, a quantitative value for the energy of the highest H2_2O occupied levels is still lacking. For experiment, this is due to the H2_2O levels being obscured by hybridization with TiO2_2(110) levels in the difference spectra obtained via ultraviolet photoemission spectroscopy (UPS). For theory, this is due to inherent difficulties in properly describing many-body effects at the H2_2O-TiO2_2(110) interface. Using the projected density of states (DOS) from state-of-the-art quasiparticle (QP) G0W0G_0W_0, we disentangle the adsorbate and surface contributions to the complex UPS spectra of H2_2O on TiO2_2(110). We perform this separation as a function of H2_2O coverage and dissociation on stoichiometric and reduced surfaces. Due to hybridization with the TiO2_2(110) surface, the H2_2O 3a1_1 and 1b1_1 levels are broadened into several peaks between 5 and 1 eV below the TiO2_2(110) valence band maximum (VBM). These peaks have both intermolecular and interfacial bonding and antibonding character. We find the highest occupied levels of H2_2O adsorbed intact and dissociated on stoichiometric TiO2_2(110) are 1.1 and 0.9 eV below the VBM. We also find a similar energy of 1.1 eV for the highest occupied levels of H2_2O when adsorbed dissociatively on a bridging O vacancy of the reduced surface. In both cases, these energies are significantly higher (by 0.6 to 2.6 eV) than those estimated from UPS difference spectra, which are inconclusive in this energy region. Finally, we apply self-consistent QPGWGW (scQPGWGW1) to obtain the ionization potential of the H2_2O-TiO2_2(110) interface.Comment: 12 pages, 12 figures, 1 tabl

    Adaptation to Visual Feedback Delay Influences Visuomotor Learning

    Get PDF
    Computational theory of motor control suggests that the brain continuously monitors motor commands, to predict their sensory consequences before actual sensory feedback becomes available. Such prediction error is a driving force of motor learning, and therefore appropriate associations between motor commands and delayed sensory feedback signals are crucial. Indeed, artificially introduced delays in visual feedback have been reported to degrade motor learning. However, considering our perceptual ability to causally bind our own actions with sensory feedback, demonstrated by the decrease in the perceived time delay following repeated exposure to an artificial delay, we hypothesized that such perceptual binding might alleviate deficits of motor learning associated with delayed visual feedback. Here, we evaluated this hypothesis by investigating the ability of human participants to adapt their reaching movements in response to a novel visuomotor environment with 3 visual feedback conditions—no-delay, sudden-delay, and adapted-delay. To introduce novelty into the trials, the cursor position, which originally indicated the hand position in baseline trials, was rotated around the starting position. In contrast to the no-delay condition, a 200-ms delay was artificially introduced between the cursor and hand positions during the presence of visual rotation (sudden-delay condition), or before the application of visual rotation (adapted-delay condition). We compared the learning rate (representing how the movement error modifies the movement direction in the subsequent trial) between the 3 conditions. In comparison with the no-delay condition, the learning rate was significantly degraded for the sudden-delay condition. However, this degradation was significantly alleviated by prior exposure to the delay (adapted-delay condition). Our data indicate the importance of appropriate temporal associations between motor commands and sensory feedback in visuomotor learning. Moreover, they suggest that the brain is able to account for such temporal associations in a flexible manner

    Sensorimotor adaptation as a behavioural biomarker of early spinocerebellar ataxia type 6.

    Get PDF
    Early detection of the behavioural deficits of neurodegenerative diseases may help to describe the pathogenesis of such diseases and establish important biomarkers of disease progression. The aim of this study was to identify how sensorimotor adaptation of the upper limb, a cerebellar-dependent process restoring movement accuracy after introduction of a perturbation, is affected at the pre-clinical and clinical stages of spinocerebellar ataxia type 6 (SCA6), an inherited neurodegenerative disease. We demonstrate that initial adaptation to the perturbation was significantly impaired in the eighteen individuals with clinical motor symptoms but mostly preserved in the five pre-clinical individuals. Moreover, the amount of error reduction correlated with the clinical symptoms, with the most symptomatic patients adapting the least. Finally both pre-clinical and clinical individuals showed significantly reduced de-adaptation performance after the perturbation was removed in comparison to the control participants. Thus, in this large study of motor features in SCA6, we provide novel evidence for the existence of subclinical motor dysfunction at a pre-clinical stage of SCA6. Our findings show that testing sensorimotor de-adaptation could provide a potential predictor of future motor deficits in SCA6

    Interpretation of Digital Mammograms: Comparison of Speed and Accuracy of Soft-Copy versus Printed-Film Display

    Get PDF
    PURPOSE: To compare the speed and accuracy of the interpretations of digital mammograms by radiologists by using printed-film versus soft-copy display. MATERIALS AND METHODS: After being trained in interpretation of digital mammograms, eight radiologists interpreted 63 digital mammograms, all with old studies for comparison. All studies were interpreted by all readers in soft-copy and printed-film display, with interpretations of images in the same cases at least 1 month apart. Mammograms were interpreted in cases that included six biopsy-proved cancers and 20 biopsy-proved benign lesions, 20 cases of probably benign findings in patients who underwent 6-month follow-up, and 17 cases without apparent findings. Area under the receiver operating characteristic curve (Az), sensitivity, and specificity were calculated for soft-copy and printed-film display. RESULTS: There was no significant difference in the speed of interpretation, but interpretations with soft-copy display were slightly faster. The differences in Az, sensitivity, and specificity were not significantly different; Az and sensitivity were slightly better for interpretations with printed film, and specificity was slightly better for interpretations with soft copy. CONCLUSION: Interpretation with soft-copy display is likely to be useful with digital mammography and is unlikely to significantly change accuracy or speed

    Radiologists' preferences for digital mammographic display

    Get PDF
    PURPOSE: To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. MATERIALS AND METHODS: Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. RESULTS: For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. CONCLUSION: When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily

    Image Processing Algorithms for Digital Mammography: A Pictorial Essay

    Get PDF
    Digital mammography systems allow manipulation of fine differences in image contrast by means of image processing algorithms. Different display algorithms have advantages and disadvantages for the specific tasks required in breast imaging—diagnosis and screening. Manual intensity windowing can produce digital mammograms very similar to standard screen-film mammograms but is limited by its operator dependence. Histogram-based intensity windowing improves the conspicuity of the lesion edge, but there is loss of detail outside the dense parts of the image. Mixture-model intensity windowing enhances the visibility of lesion borders against the fatty background, but the mixed parenchymal densities abutting the lesion may be lost. Contrast-limited adaptive histogram equalization can also provide subtle edge information but might degrade performance in the screening setting by enhancing the visibility of nuisance information. Unsharp masking enhances the sharpness of the borders of mass lesions, but this algorithm may make even an indistinct mass appear more circumscribed. Peripheral equalization displays lesion details well and preserves the peripheral information in the surrounding breast, but there may be flattening of image contrast in the nonperipheral portions of the image. Trex processing allows visualization of both lesion detail and breast edge information but reduces image contrast
    corecore