65 research outputs found

    Conformal stereotactic radiosurgery treatment: plan evaluation methods and results

    Full text link
    The purpose of our study was the objective evaluation of micro-multileaf collimator (mMLC)-based stereotactic radiosurgery treatment plans. Forty-seven patients, 71 lesions received static beam conformal stereotactic radiosurgery treatment in our institute between November 2005 and June 2008. Target volume and organs at risk were outlined on a MRI-CT image fusion basis. BrainSCAN 5.31 system (BrainLAB AG, Heimstetten, Germany) was used for treatment planning, Elekta Presice TS linear accelerator (Elekta Oncology Systems Ltd, Crawley, UK) and BrainLAB m3 mMLC were used for treatment delivery. An invasive head frame, mounted to the treatment table, was used with four screws for patient head fixation. Treatment plans were analysed with objective parameters, such as conformal index (COIN), homogeneity index (HI), coverage index (CI) and healthy tissue relative overdose factor (HTOF) tools. x2 tests were performed between COIN, HI and the geometrical parameters of the target volume (lesion volume - LV, lesion-organ distance - LOD, lesion deformity index - LDI). Mean value of COIN, HI, HTOF and CI was 0.52 (SD 0.13), 1.16 (SD 0.1), 0.88 (SD 0.53), and 0.94 (SD 0.11), respectively. COIN significantly correlated with (p<0.001 in all three cases), while HI was independent of LV, LOD, LDI (p=0.94; 0.14 and 0.72). COIN is similar, HTOF is less than data from the literature. According to our results geometrical parameters of the target volume (size, location, deformation) significantly influence the COIN, but they have no effect on HI

    Exclusive neuronal expression of SUCLA2 in the human brain

    Get PDF
    SUCLA2 encodes the ATP-forming subunit (A-SUCL-) of succinyl-CoA ligase, an enzyme of the citric acid cycle. Mutations in SUCLA2 lead to a mitochondrial disorder manifesting as encephalomyopathy with dystonia, deafness and lesions in the basal ganglia. Despite the distinct brain pathology associated with SUCLA2 mutations, the precise localization of SUCLA2 protein has never been investigated. Here we show that immunoreactivity of A-SUCL- in surgical human cortical tissue samples was present exclusively in neurons, identified by their morphology and visualized by double labeling with a fluorescent Nissl dye. A-SUCL- immunoreactivity co-localized >99% with that of the d subunit of the mitochondrial F0-F1 ATP synthase. Specificity of the anti-A-SUCL- antiserum was verified by the absence of labeling in fibroblasts from a patient with a complete deletion of SUCLA2. A-SUCL- immunoreactivity was absent in glial cells, identified by antibodies directed against the glial markers GFAP and S100. Furthermore, in situ hybridization histochemistry demonstrated that SUCLA2 mRNA was present in Nissl-labeled neurons but not glial cells labeled with S100. Immunoreactivity of the GTP-forming subunit (G-SUCL-) encoded by SUCLG2, or in situ hybridization histochemistry for SUCLG2 mRNA could not be demonstrated in either neurons or astrocytes. Western blotting of post mortem brain samples revealed minor G-SUCL- immunoreactivity that was however, not upregulated in samples obtained from diabetic versus non-diabetic patients, as has been described for murine brain. Our work establishes that SUCLA2 is expressed exclusively in neurons in the human cerebral cortex

    Epidemiology, Species Distribution, Antifungal Susceptibility and Outcome of Nosocomial Candidemia in a Tertiary Care Hospital in Italy

    Get PDF
    Candida is an important cause of bloodstream infections (BSI), causing significant mortality and morbidity in health care settings. From January 2008 to December 2010 all consecutive patients who developed candidemia at San Martino University Hospital, Italy were enrolled in the study. A total of 348 episodes of candidaemia were identified during the study period (January 2008–December 2010), with an incidence of 1,73 episodes/1000 admissions. Globally, albicans and non-albicans species caused around 50% of the cases each. Non-albicans included Candida parapsilosis (28.4%), Candida glabrata (9.5%), Candida tropicalis (6.6%), and Candida krusei (2.6%). Out of 324 evaluable patients, 141 (43.5%) died within 30 days from the onset of candidemia. C. parapsilosis candidemia was associated with the lowest mortality rate (36.2%). In contrast, patients with C. krusei BSI had the highest mortality rate (55.5%) in this cohort. Regarding the crude mortality in the different units, patients in Internal Medicine wards had the highest mortality rate (54.1%), followed by patients in ICU and Hemato-Oncology wards (47.6%)

    A Miniature Optical Neuronavigation System for CT-Guided Stereotaxy

    No full text
    Background and Objective: Neuronavigation devices have progressed over the past 2 decades, but logistical limitations remain for many stereotactic procedures. We describe our technique and accuracy for a novel miniature optical tracking system which overcomes these limitations. Method: The minioptical tracking system uses a miniature video camera mounted on a rigid cannula to determine cannula location and orientation relative to a patient-attached sticker containing reference markers. A CT scan is used to register these markers to the anatomy and a user-selected target. A computer displays the cannula guidance information to the target. Bench testing was performed on 225 targets in a custom test phantom and additional testing was performed on 20 small targets in an anthropomorphic head phantom to determine the practical accuracy and workflow. Results: The phantom study demonstrated that 3-D navigation accuracy is 1.41 ± 0.53 mm. There was a 100% head phantom study success rate for the 20 small targets. Conclusions: The resulting accuracy data demonstrated good correlation with the CT data, and the clinical simulation workflow indicated its potential usefulness for common neurosurgical applications. Furthermore, this small-footprint tracking technology does not experience the traditional environmentally induced issues or the requirement of pin-based head fixation, allowing for use in the neurointensive care unit and the emergency department. © 2013 S. Karger AG, Basel

    Novel ion exchange chromatography method for nca arsenic separation

    No full text
    A high-performance liquid chromatography (HPLC) device equipped with an anion exchange column was usedto isolate nca 77As from reactor irradiated natGeO2 targets. The oxidation states of the isotope 77As during theprocess was verified by thin layer chromatography. The radionuclidic purity of the separated fractions waschecked by gamma measurements and it was found to be 99.91% for the As fraction. The elaborated method wasapplied to separate the isotope 74As from cyclotron irradiated natGeO2 targets too
    corecore