129 research outputs found
Architecture of a Silicon Strip Beam Position Monitor
A collaboration between Fermilab and the Institute for High Energy Physics
(IHEP), Beijing, has developed a beam position monitor for the IHEP test beam
facility. This telescope is based on 5 stations of silicon strip detectors
having a pitch of 60 microns. The total active area of each layer of the
detector is about 12x10 cm2. Readout of the strips is provided through the use
of VA1` ASICs mounted on custom hybrid printed circuit boards and interfaced to
Adapter Cards via copper-over-kapton flexible circuits. The Adapter Cards
amplify and level-shift the signal for input to the Fermilab CAPTAN data
acquisition nodes for data readout and channel configuration. These nodes
deliver readout and temperature data from triggered events to an analysis
computer over gigabit Ethernet links.Comment: Submitted to TWEPP 201
Altered Activation Of The Rostral Anterior Cingulate Cortex In The Context Of Emotional Face Distractors In Children And Adolescents With Anxiety Disorders
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/109274/1/da22289.pd
Recommended from our members
Using modern software tools to design, simulate and test a Level 1 trigger sub-system for the D Zero Detector
This paper describes a system which uses a commercial spreadsheet program and commercial hardware on an IBM PC to develop and test a track finding system for the D Zero Level 1 scintillating Fiber Trigger. The trigger system resides in a VME crate. This system allows the user to generate test input, write the pattern to the hardware simulate the results in software, read the hardware result: compare the results and inform the user of any differences
The D0 Run IIb Luminosity Measurement
An assessment of the recorded integrated luminosity is presented for data
collected with the D0 detector at the Fermilab Tevatron Collider from June 2006
to September 2011 (Run IIb). In addition, a measurement of the effective cross
section for inelastic interactions, also referred to as the luminosity
constant, is reported. This measurement incorporates new features that lead to
a substantial improvement in the precision of the result. A luminosity constant
of \sigma_{LM} = 48.3\pm1.9\pm0.6 mb is obtained, where the first uncertainty
is due to the accuracy of the inelastic cross section used by both CDF and D0,
and the second uncertainty is due to D0 sources. The recorded luminosity for
the highest E_T jet trigger is L_rec = 9.2 \pm 0.4 fb^{-1}, with a relative
uncertainty of 4.3%.Comment: 20 pages, 23 figure
Recommended from our members
Microsecond delays on non-real time operating systems
We have developed microsecond timing and profiling software that runs on standard Windows and Linux based operating systems. This software is orders of magnitudes better than most of the standard native functions in wide use. Our software libraries calibrate RDTSC in microseconds or seconds to provide two different types of delays: a ''Guaranteed Minimum'' and a precision ''Long Delay'', which releases to the kernel. Both return profiling information of the actual delay
Recommended from our members
The design of a hardware testing system for the D Zero Detector
Testing a system as large as the D Zero data acquisition system is difficult. This paper describes the use of IBM compatible personal computers in a hardware test system that can run on any size system from an engineer's test bench to the entire subsystem in the D Zero Detector. The test system uses a PC to VME bus interface for the local testing and the Token Ring network for more global testing. This system has been implemented for several different hardware systems in D Zero
Childhood poverty is associated with altered hippocampal function and visuospatial memory in adulthood
Childhood poverty is a risk factor for poorer cognitive performance during childhood and adulthood. While evidence linking childhood poverty and memory deficits in adulthood has been accumulating, underlying neural mechanisms are unknown. To investigate neurobiological links between childhood poverty and adult memory performance, we used functional magnetic resonance imaging (fMRI) during a visuospatial memory task in healthy young adults with varying income levels during childhood. Participants were assessed at age 9 and followed through young adulthood to assess income and related factors. During adulthood, participants completed a visuospatial memory task while undergoing MRI scanning. Patterns of neural activation, as well as memory recognition for items, were assessed to examine links between brain function and memory performance as it relates to childhood income. Our findings revealed associations between item recognition, childhood income level, and hippocampal activation. Specifically, the association between hippocampal activation and recognition accuracy varied as a function of childhood poverty, with positive associations at higher income levels, and negative associations at lower income levels. These prospective findings confirm previous retrospective results detailing deleterious effects of childhood poverty on adult memory performance. In addition, for the first time, we identify novel neurophysiological correlates of these deficits localized to hippocampus activation
Pennsylvania Folklife Vol. 27, Folk Festival Supplement
• Hex Signs: A Living Tradition • Decoys and How to Make Them • Kutztown\u27s Plain People • The Old Country Kitchen: Where Food Preparation was an Art • Wooden Toys, Games and Puzzles: The Delight of All Children • A Sketch of the Seminar Stage Programs • Festival Focus • Folk Festival Programs • The Furniture-Makers at the Kutztown Festival • The Muzzle-Loading Gunsmith • Those Rare Things Called Antiques! • Mouth-Watering Baked Goods, Fresh From the Ovens! • The Art of the Potterhttps://digitalcommons.ursinus.edu/pafolklifemag/1079/thumbnail.jp
- …