36 research outputs found

    A new resorbable device for ligation of blood vessels - A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.</p> <p>Methods</p> <p>The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.</p> <p>The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.</p> <p>Results</p> <p>The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, <it>n </it>= 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, <it>n </it>= 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.</p> <p>Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.</p> <p>Conclusions</p> <p>Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.</p

    Prospective study on the mismatch concept in acute stroke patients within the first 24 h after symptom onset - 1000Plus study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The mismatch between diffusion weighted imaging (DWI) lesion and perfusion imaging (PI) deficit volumes has been used as a surrogate of ischemic penumbra. This pathophysiology-orientated patient selection criterion for acute stroke treatment may have the potential to replace a fixed time window. Two recent trials - DEFUSE and EPITHET - investigated the mismatch concept in a multicenter prospective approach. Both studies randomized highly selected patients (n = 74/n = 100) and therefore confirmation in a large consecutive cohort is desirable. We here present a single-center approach with a 3T MR tomograph next door to the stroke unit, serving as a bridge from the ER to the stroke unit to screen all TIA and stroke patients. Our primary hypothesis is that the prognostic value of the mismatch concept is depending on the vessel status. Primary endpoint of the study is infarct growth determined by imaging, secondary endpoints are neurological deficit on day 5-7 and functional outcome after 3 months.</p> <p>Methods and design</p> <p>1000Plus is a prospective, single centre observational study with 1200 patients to be recruited. All patients admitted to the ER with the clinical diagnosis of an acute cerebrovascular event within 24 hours after symptom onset are screened. Examinations are performed on day 1, 2 and 5-7 with neurological examination including National Institute of Health Stroke Scale (NIHSS) scoring and stroke MRI including T2*, DWI, TOF-MRA, FLAIR and PI. PI is conducted as dynamic susceptibility-enhanced contrast imaging with a fixed dosage of 5 ml 1 M Gadobutrol. For post-processing of PI, mean transit time (MTT) parametric images are determined by deconvolution of the arterial input function (AIF) which is automatically identified. Lesion volumes and mismatch are measured and calculated by using the perfusion mismatch analyzer (PMA) software from ASIST-Japan. Primary endpoint is the change of infarct size between baseline examination and day 5-7 follow up.</p> <p>Discussions</p> <p>The aim of this study is to describe the incidence of mismatch and the predictive value of PI for final lesion size and functional outcome depending on delay of imaging and vascular recanalization. It is crucial to standardize PI for future randomized clinical trials as for individual therapeutic decisions and we expect to contribute to this challenging task.</p> <p>Trial Registration</p> <p>clinicaltrials.gov NCT00715533</p

    An investigation in the correlation between Ayurvedic body-constitution and food-taste preference

    Get PDF

    Pulping catalysts from lignin: the Diels-Alder step

    Get PDF
    "July 2001."Submitted as book chapter in Advances in Chemical Modification, Properties and Usage of Lignin

    Degradation kinetics of biodegradable DL-polylactic acid biodegradable implants depending on the site of implantation

    Get PDF
    FUNDAMENTO: O fenômeno da isquemia e reperfusão intestinal é um evento frequente na clínica e está associado a repercussões deletérias em órgãos a distância, em especial ao coração. OBJETIVO: Investigar a expressão gênica do estresse oxidativo e defesa antioxidante no coração de camundongos isogênicos, submetidos a isquemia e reperfusão intestinal (IR). MÉTODOS: Doze camundongos (C57BL/6) foram distribuídos em dois grupos: Grupo IR (GIR) com 60 min de oclusão da artéria mesentérica superior, seguidos de 60 min de reperfusão. Grupo Controle (GC) submetidos a anestesia e a laparotomia sem o procedimento de IR observados por 120 min. As amostras de intestino e coração foram processadas pelo método (RT-qPCR / Reverse transcriptase - quantitative Polymerase Chain Reaction) para determinar a expressão gênica de 84 genes relacionados ao estresse oxidativo ("t" de Student, p < 0,05). RESULTADOS: Observou-se no tecido intestinal (GIR) uma expressão significantemente aumentada em 65 (74,71%) genes em relação ao tecido normal (GC), e 37 (44,04%) genes estiveram hiperexpressos (maior que três vezes o limiar permitido pelo algoritmo). No tocante aos efeitos da I/R intestinal a distância no tecido cardíaco verificou-se a expressão significantemente aumentada de 28 genes (33,33%), mas somente oito genes (9,52%) se hiperexpressaram três vezes acima do limiar. Quatro (7,14%) desses oito genes se expressaram simultaneamente nos tecidos intestinal e cardíaco. No GIR notaram-se cardiomiócitos com núcleos de menor tamanho, picnóticos, ricos em heterocromatina e raros nucléolos, indicando sofrimento cardíaco. CONCLUSÃO: A I/R intestinal promoveu a hiperexpressão estatisticamente significante de oito genes associados ao estresse oxidativo a distância no tecido miocárdico
    corecore