22 research outputs found

    Review of Matrix Metalloproteinases’ Effect on the Hybrid Dentin Bond Layer Stability and Chlorhexidine Clinical Use to Prevent Bond Failure

    Get PDF
    This review describes the relationship between dentin collagen hybrid bond layer degradation and the Matrix Metalloproteinases (MMPs) after their release by acid etch and rinse adhesives and self etching bonding adhesives that can reduce the bond stability over time. MMP-2, MMP-8 and MMP-9 are indicated as the active proteases that breakdown the collagen fibrils in the hybrid bond layer. Phosphoric acid in the acid etch and rinse bonding process and acid primers in the self etch process are implicated in the release of these proteases and their activation by several non-collagen proteins also released from dentin by the etching. MMPs are released in saliva by salivary glands, by cells in the gingival crevices to crevicular fluid and by pulpal odontoblasts cells to the dentinal fluids. These sources may affect the hybrid layer also. Evidence of the bond strength deterioration over time and the ability of Chlorhexidine to prevent bond deterioration by inhibiting MMP action are discussed. Dentin Bonding procedure utilizing Chlorhexidine for different application times and concentrations are being developed. The application of 2% Chlorhexidine to the phosphoric acid etch surface after rinsing off the acid is the only procedure that has been clinically tested for a longer period of time and shown to prevent bond strength degradation so far. The adoption of this procedure is recommended as means of improving bond stability at this time

    A Randomized Clinical Evaluation of a One- and Two-step Self-etch Adhesive Over 24 Months

    No full text
    Objective: To evaluate the performance of All Bond SE used in a one- or two-step protocol in a 24-month randomized clinical study. Methods: Thirty-three patients with two similarly sized non-carious cervical lesions participated in this study. A total of 66 restorations were placed, half using the one-step All Bond SE protocol (SE-1) and the other half using the two-step All Bond SE protocol (SE-2). The restorations were evaluated at baseline and after 6, 12 and 24 months following the modified USPHS criteria and analyzed by the McNemar`s test and Fisher`s exact test (alpha=0.05). Results: After 24 months, six SE-1 and four SE-2 restorations were rated as Bravo in marginal discoloration The retention rates for SE-1 and SE-2 were 84.8% and 90.9%, respectively, after 24 months. Compared to baseline, the retention rate for SE-1 was statistically lower. Conclusions: All Bond SE used in the one- or two-step protocol resulted in high retention rates after 24 months.BISCO, IncNational Council for Scientific and Technological Development (CNPq)[305075/2006-3]National Council for Scientific and Technological Development (CNPq)[303933/2007-0

    Two year effects of Chlorhexidine containing adhesives on the in vitro durability of resin dentin interfaces and modeling of drug release

    No full text
    Objectives: To evaluate the effects of addition of diacetate chlorhexidine (CHX) at different concentrations into two etch-and-rinse adhesive systems on CHX release, as well as the immediate (IM) and two-year (2-Y) resin-dentin microtensile bond strength (mu TBS) and nano-leakage (NL). Methods: CHX was added to XP Bond (XP) and Ambar (AM) at concentrations of 0.0 wt% (control); 0.01 wt%; 0.05 wt%; and 0.1 to 0.2 wt%. To assess the cumulative CHX release, adhesive disks were made in a metallic matrix and after light-curing were stored in water. Ultraviolet spectrophotometric measurements of the storage solution were performed to examine the release kinetics of CHX. For mu TBS and NL, the occlusal enamel of molars was removed and the adhesives were applied to the dentin surface after acid etching. After composite resin build-up, specimens were sectioned to obtain mu TBS sticks. The specimens were subjected to mu TBS and NL at IM and after 2-Y. In addition, specimens underwent examination for CHX using micro-Raman spectroscopy. All data were submitted to statistical analysis (alpha=0.05). Results: With regard to CHX release, AM showed a slower and gradual release of CHX while XP released CHX more quickly (p<0.05), and CHX was still present in the hybrid layers after 2-Y. Both adhesives showed CHX release at 2-Y water storage. Both CHX-containing adhesives showed higher mu TBS values than did the control group (p<0.05).Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) 304104/2013-9 305588/2014-

    Effect of acidity of in-office bleaching gels on tooth sensitivity and whitening: a two-center double-blind randomized clinical trial

    No full text
    The study aimed to compare the tooth sensitivity (TS) and bleaching efficacy of two hydrogen peroxide gels with different pHs (acid pH [Pola Office, SDI] and the neutral pH [Pola Office+, SDI]) used for in-office bleaching. Fifty-four patients from Brazil and Chile, with right superior incisor darker than A2, were selected for this double-blind, split-mouth randomized trial. Teeth were bleached in two sessions, with 1-week interval. Each session had three applications of 8 min each, according to the manufacturer's instructions. The color changes were evaluated by subjective (Vita Classical and Vita Bleachedguide) and objective (Easy shade spectrophotometer) methods. Participants recorded TS with 0-10 visual analog scale. Color change in shade guide units (SGU) and Delta E was analyzed by Student's t test (alpha = 0.05). The absolute risk and intensity of TS were evaluated by McNemar's test and Wilcoxon-paired test, respectively (alpha = 0.05). All groups achieved the same level of whitening after 30 days of clinical evaluation. The use of a neutral in-office bleaching gel significantly decreases the absolute risk of TS (28%, 95% CI 18-41) and intensity of TS when compared to the acid bleaching gel (absolute risk of 50%, 95% CI 37-63). The use of a neutral in-office bleaching agent gel produced the same whitening degree than an acid bleaching gel but with reduced risk and intensity of tooth sensitivity. Clinicians should opt to use in-office bleaching with a neutral gel than an acid product because the former causes a significant lower risk and intensity of tooth sensitivity.National Council for Scientific and Technological Development 304105/2013-9 305588/2014-

    Effect of tetracycline on the bond performance of etch-and-rinse adhesives to dentin

    No full text
    This study evaluated the effect of modified tetracycline on the resin-dentin bond strength (”TBS), silver nitrate uptake (SNU) and solution homogeneity (SH) of two adhesives. Dentin surfaces were treated with phosphoric acid, rinsed off and either rewetted with water (control group - CO), 2% minocycline (MI), 2% doxycyline (DO) or 2% chlorhexidine (CH). Adhesive systems (Adper Single Bond 2 and Prime Bond NT) and composite were applied and light-polymerized. Specimens were sectioned to obtain bonded sticks (0.8 mmÂČ) to test under tension at 0.5 mm/min. For SNU, specimens were immersed in silver nitrate and analyzed by EDX-SEM. SH was qualitatively analyzed after mixing the adhesives with different solvent-based solutions containing MI, DO and CH. Lower ”TBS values were observed in the DO group compared with MI and CH (p = 0.01). Lower SNU was observed for MI and CH. The lowest ”TBS for both adhesives was observed for the DO group (p = 0.01). Signs of phase separation were observed for DO with both adhesives. MI or CH used as rewetting solutions after acid etching did not affect the ”TBS and hybrid layer quality

    Influence of chlorhexidine application on longitudinal adhesive bond strength in deciduous teeth

    No full text
    The aim of this study was to evaluate the influence of applying 2% chlorhexidine for 30 seconds after phosphoric acid conditioning of dentin on the immediate and long-term bond strengths in deciduous teeth. The occlusal enamel was removed from 40 human sound deciduous molars, which were exfoliated by natural means, and the dentin was conditioned with 37% phosphoric acid for 15 seconds and washed with running water. The specimens were divided into two groups of 20 teeth. The test group received an application of 2% chlorhexidine for 30 seconds prior to a three-step etch-and-rinse adhesive system, whereas the control group received only the adhesive system. Three cylindrical restorations were made with a composite resin for each tooth. Ten teeth in each group were submitted to a microshear bond strength test after 24 hours, while the remaining teeth were stored in distilled water at 37 °C for 6 months before testing the microshear bond strength. The test group had a higher bond strength than did the control group after 6 months of storage. No statistical differences were found when groups with the same dentin treatment were compared at different times. Short applications of chlorhexidine at low concentrations prevent hybrid layer degradation and positively affect bond strength over time
    corecore