102 research outputs found
Type F congenital quadricuspid aortic valve: A very rare case diagnosed by 3-dimenional transoesophageal echocardiography
Congenital quadricuspid aortic valve (QAV) is a rare cardiac anomaly. Several different anatomical variations of a quadricuspid aortic valve have been described. Aortic regurgitation is the predominant valvular dysfunction associated with QAV and patients tend to present in their 5(th) or 6(th) decade of life. This anomaly is rarely picked up by transthoracic echocardiogram (TTE). A comprehensive transoesophageal echocardiography (TOE) study is more likely to diagnose it. We describe a very rare type of QAV - Type F in a 52-year-old lady who presented with symptoms of shortness of breath and pre-syncope. We include TOE images and intra-operative valve images
Survival and Recurrence of Endocarditis following Mechanical vs. Biological Aortic Valve Replacement for Endocarditis in Patients Aged 40 to 65 Years: Data from the INFECT-Registry
Background: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. Methods: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. Results: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322–0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077–0.933, p = 0.039). Conclusions: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients
Rest and Dobutamine stress echocardiography in the evaluation of mid-term results of mitral valve repair in Barlow's disease
BACKGROUND: Surgical "anatomical" repair is the most frequent technique used to correct mitral regurgitation due to severe myxomatous valve disease. Debate, however, persists on the efficacy of this technique, as well as on the durability of the repaired valve, and on its functioning and hemodynamics under stress conditions. Thus, a basal and Dobutamine echocardiographic (DSE) study was carried out to evaluate these parameters at mid-term follow-up. METHODS AND RESULTS: Twenty patients selected for the study (12 men and 8 women, mean age 60 ± 9 years) underwent pre- and post-operative transthoracic echocardiography (TTE) and intra-operative transesophageal echocardiography (TEE). At mid-term follow-up (20 ± 5 months) all patients underwent rest TTE and DSE (3 min. dose increments up to 40 microg/Kg/min protocol). Pre-discharge and one-month TTE showed absence of MR in 11 pts., trivial or mild MR in 9 pts. and normal mitral valve area and gradients. Mid-term TTE showed decrease in left atrial and ventricular dimension, in pulmonary artery pressure (sPAP) and grade of MR. During DSE a significant increase in mitral valve area, maximum and mean gradients, sPAP, heart rate and cardiac output and a decrease in systolic annular diameter and left ventricular volume were found; in 6 pts. a transient left ventricular outflow tract obstruction was observed. CONCLUSION: Basal and Dobutamine stress echocardiography proved to be valuable tools for evaluation of mid-term results of mitral valve repair. In our study population, the surgical technique employed had a favourable impact on several cardiac parameters, evaluated by these methods
Bartonella haenselae infective endocarditis following transcatheter edge-to-edge mitral valve repair : a case report
Infective endocarditis following a Mitraclip procedure might be an under-recognized complication. We describe the case of infective endocarditis by Bartonella henselae as a late complication in a patient with a previously implanted MitraClip system for mitral valve repair. Due to the severity of infection, surgical treatment was performed despite the high preoperative surgical risk, but recurrence of endocarditis of the biological valve implanted occurred. Although infection with Bartonella is known as a possible source of endocarditis, it has never been described before in relation to failed MitraClip therapy
Successful resection of an epicardial cyst
Cases of pericardial cyst have been reported by many authors, but the incidence of epicardial cyst originating directly from the epicardium in the pericardial cavity is extremely rare. A case of successful resection of epicardial cyst fortuitously discovered and diagnosed during cardiac operation is presented
[Right pleural effusion in aortic dissecting aneurysm]
Right hemorrhagic pleural effusion may be a presenting sign of thoracic aortic dissecting aneurysm. We describe 2 cases of massive right hemorrhagic pleural effusion and dissection of the descending aorta (type B) detected at tomographic scan. Transesophageal echocardiography ruled out a retrograde dissection of the ascending aorta. Right hemorrhagic pleural effusion is an unusual clinical presentation in thoracic aorta dissection and, up to now, the underling pathophysiology of this sign has not been defined yet
- …