358 research outputs found

    Testing a fault tolerant mixed-signal design under TID and heavy ions

    Get PDF
    This work presents results of three distinctradiation tests performed upon a fault tolerant data acqui-sition system comprising a design diversity redundancytechnique. The first and second experiments are Total Ion-izing Dose (TID) essays, comprising gamma and X-rayirradiations. The last experiment considers single eventeffects, in which two heavy ion irradiation campaignsare carried out. The case study system comprises threeanalog-to-digital converters and two software-based vot-ers, besides additional software and hardware resourcesused for controlling, monitoring and memory manage-ment. The applied Diversity Triple Modular Redundancy(DTMR) technique, comprises different levels of diversity(temporal and architectural). The circuit was designed ina programmable System-on-Chip (PSoC), fabricated in a130nm CMOS technology process. Results show that thetechnique may increase the lifetime of the system underTID if comparing with a non-redundant implementation.Considering the heavy ions experiments the system wasproved effective to tolerate 100% of the observed errorsoriginated in the converters, while errors in the process-ing unit present a higher criticality. Critical errors occur-ring in one of the voters were also observed. A secondheavy ion campaign was then carried out to investigatethe voters reliability, comparing the the dynamic cross sec-tion of three different software-based voter schemes im-plemented in the considered PSoC

    META Score: An International Consensus Scoring System on Mesh-Tissue Adhesions

    Get PDF
    Background: Currently, the lack of consensus on postoperative mesh-tissue adhesion scoring leads to incomparable scientific results. The aim of this study was to develop an adhesion score recognized by experts in the field of hernia surgery. Methods: Authors of three or more previously published articles on both mesh-tissue adhesion scores and postoperative adhesions were marked as experts. They were queried on seven items using a modified Delphi method. The items concerned the utility of adhesion scoring models, the appropriateness of macroscopic and microscopic variables, the range and use of composite scores or subscores, adhesion-related complications and follow-up length. This study comprised two questionnaire-based rounds and one consensus meeting. Results: The first round was completed by 23 experts (82%), the second round by 18 experts (64%). Of those 18 experts, ten were able to participate in the final consensus meeting and all approved the final proposal. From a total of 158 items, consensus was reached on 90 items. The amount of mesh surface covered with adhesions, tenacity and thickness of adhesions and organ involvement was concluded to be a minimal set of variables to be communicated separately in each future study on mesh adhesions. Conclusion: The MEsh Tissue Adhesion scoring system is the first consensus-based scoring system with a wide backing of renowned experts and can be used to assess mesh-related adhesions. By including this minimal set of variables in future research interstudy comparability and objectivity can be increased and eventually linked to clinically relevant outcomes

    Conformation-regulated mechanosensory control via titin domains in cardiac muscle

    Get PDF
    The giant filamentous protein titin is ideally positioned in the muscle sarcomere to sense mechanical stimuli and transform them into biochemical signals, such as those triggering cardiac hypertrophy. In this review, we ponder the evidence for signaling hotspots along the titin filament involved in mechanosensory control mechanisms. On the way, we distinguish between stress and strain as triggers of mechanical signaling events at the cardiac sarcomere. Whereas the Z-disk and M-band regions of titin may be prominently involved in sensing mechanical stress, signaling hotspots within the elastic I-band titin segment may respond primarily to mechanical strain. Common to both stress and strain sensor elements is their regulation by conformational changes in protein domains

    Thai visitors’ expectations and experiences of explainer interaction within a science museum context

    Get PDF
    © The Author(s) 2015. In Western literature, there is evidence that museum explainers offer significant potential for enhancing visitors’ learning through influencing their knowledge, content, action, behaviour and attitudes. However, little research has focused on the role of explainers in other cultural contexts. This study explored interactions between visitors and museum explainers within the setting of Thailand. Two questionnaires were distributed to 600 visitors and 41 museum explainers. The results demonstrated both potential similarities and differences with Western contexts. Explainers appeared to prefer didactic approaches, focussing on factual knowledge rather than encouraging deep learning. Two-way communication, however, appeared to be enhanced by the use of a ‘pseudo-sibling relationship’ by explainers. Traditional Thai social reserve was reduced through such approaches, with visitors taking on active learning roles. These findings have implications for training museum explainers in non-Western cultures, as well as museum communication practice more generally

    Cytoskeletal protein kinases: titin and its relations in mechanosensing

    Get PDF
    Titin, the giant elastic ruler protein of striated muscle sarcomeres, contains a catalytic kinase domain related to a family of intrasterically regulated protein kinases. The most extensively studied member of this branch of the human kinome is the Ca2+–calmodulin (CaM)-regulated myosin light-chain kinases (MLCK). However, not all kinases of the MLCK branch are functional MLCKs, and about half lack a CaM binding site in their C-terminal autoinhibitory tail (AI). A unifying feature is their association with the cytoskeleton, mostly via actin and myosin filaments. Titin kinase, similar to its invertebrate analogue twitchin kinase and likely other “MLCKs”, is not Ca2+–calmodulin-activated. Recently, local protein unfolding of the C-terminal AI has emerged as a common mechanism in the activation of CaM kinases. Single-molecule data suggested that opening of the TK active site could also be achieved by mechanical unfolding of the AI. Mechanical modulation of catalytic activity might thus allow cytoskeletal signalling proteins to act as mechanosensors, creating feedback mechanisms between cytoskeletal tension and tension generation or cellular remodelling. Similar to other MLCK-like kinases like DRAK2 and DAPK1, TK is linked to protein turnover regulation via the autophagy/lysosomal system, suggesting the MLCK-like kinases have common functions beyond contraction regulation

    The impact of maternal HIV infection on cord blood lymphocyte subsets and cytokine profile in exposed non-infected newborns

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Children born to HIV+ mothers are exposed intra-utero to several drugs and cytokines that can modify the developing immune system, and influence the newborn's immune response to infections and vaccines. We analyzed the relation between the distribution of cord blood lymphocyte subsets and cytokine profile in term newborns of HIV+ mothers using HAART during pregnancy and compared them to normal newborns.</p> <p>Methods</p> <p>In a prospective, controlled study, 36 mother-child pairs from HIV+ mothers and 15 HIV-uninfected mothers were studied. Hematological features and cytokine profiles of mothers at 35 weeks of pregnancy were examined. Maternal and cord lymphocyte subsets as well as B-cell maturation in cord blood were analyzed by flow cytometry. The non-stimulated, as well as BCG- and PHA-stimulated production of IL2, IL4, IL7, IL10, IL12, IFN-γ and TNF-alpha in mononuclear cell cultures from mothers and infants were quantified using ELISA.</p> <p>Results</p> <p>After one year follow-up none of the exposed infants became seropositive for HIV. An increase in B lymphocytes, especially the CD19/CD5+ ones, was observed in cord blood of HIV-exposed newborns. Children of HIV+ hard drug using mothers had also an increase of immature B-cells. Cord blood mononuclear cells of HIV-exposed newborns produced less IL-4 and IL-7 and more IL-10 and IFN-γ in culture than those of uninfected mothers. Cytokine values in supernatants were similar in infants and their mothers except for IFN-γ and TNF-alpha that were higher in HIV+ mothers, especially in drug abusing ones. Cord blood CD19/CD5+ lymphocytes showed a positive correlation with cord IL-7 and IL-10. A higher maternal age and smoking was associated with a decrease of cord blood CD4+ cells.</p> <p>Conclusions</p> <p>in uninfected infants born to HIV+ women, several immunological abnormalities were found, related to the residual maternal immune changes induced by the HIV infection and those associated with antiretroviral treatment. Maternal smoking was associated to changes in cord CD3/CD4 lymphocytes and maternal hard drug abuse was associated with more pronounced changes in the cord B cell line.</p
    corecore