21 research outputs found

    Transfer insensitive labeling technique (TILT): application to multislice functional perfusion imaging.

    No full text
    Cerebral blood flow can be studied in a multislice mode with a recently proposed perfusion sequence using inversion of water spins as an endogenous tracer without magnetization transfer artifacts. The magnetization transfer insensitive labeling technique (TILT) has been used for mapping blood flow changes at a microvascular level under motor activation in a multislice mode. In TILT, perfusion mapping is achieved by subtraction of a perfusion-sensitized image from a control image. Perfusion weighting is accomplished by proximal blood labeling using two 90 degrees radiofrequency excitation pulses. For control preparation the labeling pulses are modified such that they have no net effect on blood water magnetization. The percentage of blood flow change, as well as its spatial extent, has been studied in single and multislice modes with varying delays between labeling and imaging. The average perfusion signal change due to activation was 36.9 +/- 9.1% in the single-slice experiments and 38.1 +/- 7.9% in the multislice experiments. The volume of activated brain areas amounted to 1.51 +/- 0.95 cm3 in the contralateral primary motor (M1) area, 0.90 +/- 0.72 cc in the ipsilateral M1 area, 1.27 +/- 0.39 cm3 in the contralateral and 1.42 +/- 0.75 cm3 in the ipsilateral premotor areas, and 0.71 +/- 0.19 cm3 in the supplementary motor area

    SENSE-DTI at 3 T

    No full text
    While holding vast potential, diffusion tensor imaging (DTI) with single-excitation protocols still faces serious challenges. Limited spatial resolution, susceptibility to magnetic field inhomogeneity, and low signal-to-noise ratio (SNR) may be considered the most prominent limitations. It is demonstrated that all of these shortcomings can be effectively mitigated by the transition to parallel imaging technology and high magnetic field strength. Using the sensitivity encoding (SENSE) technique at 3 T, brain DTI was performed in nine healthy volunteers. Despite enhanced field inhomogeneity, parallel acquisition permitted both controlling geometric distortions and enhancing spatial resolution up to 0.8 mm in-plane. Heightened SNR requirements were met in part by high base sensitivity at 3 T. A further significant increase in SNR efficiency was accomplished by SENSE acquisition, exploiting enhanced encoding speed for echo time reduction. Based on the resulting image data, high-resolution tensor mapping is demonstrated
    corecore