998 research outputs found

    Effective mobilities in pseudomorphic Si/SiGe/Si p-channel metal-oxide-semiconductor field-effect transistors with thin silicon capping layers

    Get PDF
    The room-temperature effective mobilities of pseudomorphic Si/Si0.64Ge0.36/Si p-metal-oxidesemiconductor field effect transistors are reported. The peak mobility in the buried SiGe channel increases with silicon cap thickness. It is argued that SiO2/Si interface roughness is a major source of scattering in these devices, which is attenuated for thicker silicon caps. It is also suggested that segregated Ge in the silicon cap interferes with the oxidation process, leading to increased SiO2/Si interface roughness in the case of thin silicon caps

    A strained silicon cold electron bolometer using Schottky contacts

    Get PDF
    We describe optical characterisation of a strained silicon cold electron bolometer (CEB), operating on a 350 mK stage, designed for absorption of millimetre-wave radiation. The silicon cold electron bolometer utilises Schottky contacts between a superconductor and an n++ doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to 160 GHz and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of 50% for radiation coupled into the device by the planar antenna and an overall noise equivalent power, referred to absorbed optical power, of 1.1×10−16 W Hz−1/2 when the detector is observing a 300 K source through a 4 K throughput limiting aperture. Even though this optical system is not optimized, we measure a system noise equivalent temperature difference of 6 mK Hz−1/2. We measure the noise of the device using a cross-correlation of time stream data, measured simultaneously with two junction field-effect transistor amplifiers, with a base correlated noise level of 300 pV Hz−1/2 and find that the total noise is consistent with a combination of photon noise, current shot noise, and electron-phonon thermal noise

    Torsion pairs and rigid objects in tubes

    Get PDF
    We classify the torsion pairs in a tube category and show that they are in bijection with maximal rigid objects in the extension of the tube category containing the Pruefer and adic modules. We show that the annulus geometric model for the tube category can be extended to the larger category and interpret torsion pairs, maximal rigid objects and the bijection between them geometrically. We also give a similar geometric description in the case of the linear orientation of a Dynkin quiver of type A.Comment: 25 pages, 13 figures. Paper shortened. Minor errors correcte

    A consensus building exercise to determine research priorities for silver trauma

    Get PDF
    Background Emergency care research into ‘Silver Trauma’, which is simply defined as major trauma consequent upon relatively minor injury mechanisms, is facing many challenges including that at present, there is no clear prioritisation of the issues. This study aimed to determine the top research priorities to guide future research. Methods This consensus-based prioritization exercise used a three-stage modified Delphi technique. The study consisted of an idea generating (divergent) first round, a ranking evaluation in the second round, and a (convergent) consensus meeting in the third round. Results A total of 20 research questions advanced to the final round of this study. After discussing the importance and clinical significance of each research question, five research questions were prioritised by the experts; the top three research priorities were: (1). What are older people’s preferred goals of trauma care? (2). Beyond the Emergency Department (ED), what is the appropriate combined geriatric and trauma care? (3). Do older adults benefit from access to trauma centres? If so, do older trauma patients have equitable access to trauma centre compared to younger adults? Conclusion The results of this study will assist clinicians, researchers, and organisations that are interested in silver trauma in guiding their future efforts and funding toward addressing the identified research priorities

    Identification of particles with Lorentz factor up to 10410^{4} with Transition Radiation Detectors based on micro-strip silicon detectors

    Full text link
    This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to the radiating particles. A detector setup has been built and tested with particles in a wide range of Lorentz factors (from about 10310^3 to about 4×1044 \times 10^4 crossing different types of radiators. The measured double-differential (in energy and angle) spectra of the TR photons are in a reasonably good agreement with TR simulation predictions.Comment: 31 pages, 12 figures, paper published on Nuclear Instruments & Methods

    Interfacial engineering of semiconductor–superconductor junctions for high performance micro-coolers

    Get PDF
    The control of electronic and thermal transport through material interfaces is crucial for numerous micro and nanoelectronics applications and quantum devices. Here we report on the engineering of the electro-thermal properties of semiconductor-superconductor (Sm-S) electronic cooler junctions by a nanoscale insulating tunnel barrier introduced between the Sm and S electrodes. Unexpectedly, such an interface barrier does not increase the junction resistance but strongly reduces the detrimental sub-gap leakage current. These features are key to achieving high cooling power tunnel junction refrigerators, and we demonstrate unparalleled performance in silicon-based Sm-S electron cooler devices with orders of magnitudes improvement in the cooling power in comparison to previous works. By adapting the junctions in strain-engineered silicon coolers we also demonstrate efficient electron temperature reduction from 300 mK to below 100 mK. Investigations on junctions with different interface quality indicate that the previously unexplained sub-gap leakage current is strongly influenced by the Sm-S interface states. These states often dictate the junction electrical resistance through the well-known Fermi level pinning effect and, therefore, superconductivity could be generally used to probe and optimize metal-semiconductor contact behaviour

    Progress towards the first measurement of charm baryon dipole moments

    Get PDF
    Electromagnetic dipole moments of short-lived particles are sensitive to physics within and beyond the Standard Model of particle physics but have not been accessible experimentally to date. To perform such measurements it has been proposed to exploit the spin precession of channeled particles in bent crystals at the LHC. Progress that enables the first measurement of charm baryon dipole moments is reported. In particular, the design and characterization on beam of silicon and germanium bent crystal prototypes, the optimization of the experimental setup, and advanced analysis techniques are discussed. Sensitivity studies show that first measurements of Λ+c and Ξ+c baryon dipole moments can be performed in two years of data taking with an experimental setup positioned upstream of the LHCb detector. Figur
    corecore