254 research outputs found

    Heat capacity and glass transition in P2O5-H 2O solutions: Support for Mishima's conjecture on solvent water at low temperature

    Get PDF
    The P2O5-water system has the widest range of continuously glass-forming compositions known for any glassformer + water binary system. Despite the great range of structures explored by the glasses and liquids in this system, the glass transition temperature (Tg) itself varies in a simple monotonic fashion. However the values of Tg reported in the literature show wide disagreement, linked to the different methods of measurement employed. In this work we use differential scanning calorimetry (DSC) to obtain both Tg itself and the jump in heat capacity that occurs as the metastable equilibrium of the supercooled liquid relieves the non-ergodic glassy state. Our study covers the molar ratio range of H2O/P2O5 from 1.5 to 14 (corresponding to the mass fraction of P2O5 between 0.36 and 0.84), which includes the compositions corresponding to pyrophosphoric acid (H 4P2O7) and orthophosphoric acid (H 3PO4). The theoretical model of Couchman and Karasz predicts very well the glass transition temperatures of the P2O 5-H2O system over the whole composition range if the relatively large heat capacity change associated with water in aqueous solutions at the glass transition temperature is adopted, instead of the vanishingly small value observed for vapor deposited or hyperquenched pure water. Therefore, solvent water in this ambient pressure P2O5-H 2O system behaves like a different liquid, more closely resembling a high-density liquid (HDL) polyamorph, as suggested by Mishima for electrolytes at high pressures.Fil: Corti, Horacio Roberto. Comisión Nacional de Energía Atómica. Centro Atómico Constituyentes; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; ArgentinaFil: Nores Pondal, Federico Jose. Comisión Nacional de Energía Atómica. Centro Atómico Constituyentes; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Angell, C. Austen. Arizona State University; Estados Unido

    El hierro y las artes menores

    Get PDF
    S hemos de buscar las primeras manifestaciones expresadas en el hierro, por el hombre, nos tenemos que acercar a los siglos VIII y VII antes de la era cristiana; ya en esa época existía una escuela con sus características definidas e importantes, lo que hace suponer, quizá, una evolución previa sin duda alguna, de varios siglos. En los comienzos se utilizó el hierro, naturalmente, para la fabricación de armas, vale decir: espadas, flechas, lanzas y omphalos, primera industria del hombre primitivo y bocados de caballos, hachas, martillos, etc. Barcelona en el siglo XII tenía ya constituidos gremios de herreros de gran importancia; luego Valencia, en el siglo XIII, y posteriormente en París, constitúyense en el siglo XV.Universidad Nacional de La Plat

    Comparative analysis of the recovery time of the investment in thermal solar collectors in the Argentine Republic through Geographic Information Systems

    Get PDF
    El crecimiento del mercado solar térmico tanto a nivel mundial como en la Argentina, ha generado el aumento de importaciones y producción local de diversos colectores solares térmicos con características muy heterogéneas. La extensión del territorio argentino presenta una gran amplitud de temperatura y radiación solar, estos son las variables principales que afectan el rendimiento y la producción energética de los colectores solares. Es trabajo analiza el tiempo de recupero de la inversión (TRI) de 2 colectores solares típicos, placa plana y tubo de vacío, para valores de temperatura de ambiente y radiación medios, en comparación con un termotanque tradicional de eficiencia “A” con funcionamiento a gas natural y resistencia eléctrica. Determinando como varían el TRI de ambos colectores, para luego realizar mapas de la Republica Argentina mediante Sistemas de Información Geográficas (SIG) que muestren como varían el TRI en años en todo el territorio para las condiciones anteriormente mencionadas.The growth of the solar thermal market, both worldwide and in Argentina, has generated an increase in imports and local production of various solar thermal collectors with highly heterogeneous characteristics. The extension of the Argentine territory presents a great amplitude of temperature and solar radiation, these are the main variables that affect the performance and energy production of solar collectors. This work analyzes the return on investment time (RIT) of 2 typical solar collectors, flat plate and vacuum tube, for average ambient temperature and radiation values, compared to a traditional efficiency "A", hot water tank operating at natural gas and electric resistance. Determining how the RIT of both collectors vary, to then make maps of the Argentine Republic through Geographic Information Systems (GIS) that show how the RIT varies in years throughout the territory for the conditions mentioned above.Fil: Haim, Pablo Alejandro. Universidad Tecnológica Nacional. Facultad Regional Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles. Universidad de Buenos Aires. Facultad de Ingeniería. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles; ArgentinaFil: Bersalli, Germán Ariel. Institute For Advanced Sustainability Studies; AlemaniaFil: Nores Pondal, Federico Jose. Universidad Tecnológica Nacional. Facultad Regional Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles. Universidad de Buenos Aires. Facultad de Ingeniería. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles; Argentin

    Comparative analysis of the recovery time of the investment in thermal solar collectors in the Argentine Republic through Geographic Information Systems

    Get PDF
    El crecimiento del mercado solar térmico tanto a nivel mundial como en la Argentina, ha generado el aumento de importaciones y producción local de diversos colectores solares térmicos con características muy heterogéneas. La extensión del territorio argentino presenta una gran amplitud de temperatura y radiación solar, estos son las variables principales que afectan el rendimiento y la producción energética de los colectores solares. Es trabajo analiza el tiempo de recupero de la inversión (TRI) de 2 colectores solares típicos, placa plana y tubo de vacío, para valores de temperatura de ambiente y radiación medios, en comparación con un termotanque tradicional de eficiencia “A” con funcionamiento a gas natural y resistencia eléctrica. Determinando como varían el TRI de ambos colectores, para luego realizar mapas de la Republica Argentina mediante Sistemas de Información Geográficas (SIG) que muestren como varían el TRI en años en todo el territorio para las condiciones anteriormente mencionadas.The growth of the solar thermal market, both worldwide and in Argentina, has generated an increase in imports and local production of various solar thermal collectors with highly heterogeneous characteristics. The extension of the Argentine territory presents a great amplitude of temperature and solar radiation, these are the main variables that affect the performance and energy production of solar collectors. This work analyzes the return on investment time (RIT) of 2 typical solar collectors, flat plate and vacuum tube, for average ambient temperature and radiation values, compared to a traditional efficiency "A", hot water tank operating at natural gas and electric resistance. Determining how the RIT of both collectors vary, to then make maps of the Argentine Republic through Geographic Information Systems (GIS) that show how the RIT varies in years throughout the territory for the conditions mentioned above.Fil: Haim, Pablo Alejandro. Universidad Tecnológica Nacional. Facultad Regional Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles. Universidad de Buenos Aires. Facultad de Ingeniería. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles; ArgentinaFil: Bersalli, Germán Ariel. Institute For Advanced Sustainability Studies; AlemaniaFil: Nores Pondal, Federico Jose. Universidad Tecnológica Nacional. Facultad Regional Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles. Universidad de Buenos Aires. Facultad de Ingeniería. Instituto de Tecnologías del Hidrogeno y Energias Sostenibles; Argentin

    Ensayo bajo norma IRAM de colectores solares planos y de tubos evacuados : Comparación de características

    Get PDF
    Los colectores solares están en permanente equilibrio con el ambiente. La eficiencia de conversión del mismo depende de la radiación solar, la temperatura ambiente, la temperatura del agua de entrada y salida, la velocidad del viento y el caudal de circulación. De esta manera, no es posible asignar un solo valor de eficiencia a los colectores solares sino que es necesario determinar su curva de rendimiento. Esta curva representa el funcionamiento de los colectores solares bajo distintas situaciones ambientales y es necesaria para dimensionar cualquier sistema. La curva de rendimiento se determina experimentalmente bajo condiciones controladas de los parámetros mencionados y conforme a la norma IRAM 210002. En el banco de ensayos del LESES (Laboratorio de Estudios sobre energía Solar) se realizaron ensayos de diferentes colectores bajo la norma IRAM 210002. Este trabajo presenta una comparación de varios colectores ensayados y relaciona sus características constructivas con los parámetros determinados. Los resultados de este trabajo servirán para ser utilizados en el dimensionamiento de sistemas que utilicen los colectores ensayados. Asimismo, el LESES se encuentra transitando la adaptación del banco para cumplir con los requerimientos de la nueva versión de la Norma que entró en vigencia el corriente año y es objetivo del mismo, difundir la existencia de estas instalaciones para que sean consideradas a la hora de implementar una política de promoción de la energía solar térmica y para divulgar las actividades de investigación que allí se realizan.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES
    corecore