372 research outputs found
Rejection of randomly coinciding events in LiMoO scintillating bolometers using light detectors based on the Neganov-Luke effect
Random coincidences of nuclear events can be one of the main background
sources in low-temperature calorimetric experiments looking for neutrinoless
double-beta decay, especially in those searches based on scintillating
bolometers embedding the promising double-beta candidate Mo, because of
the relatively short half-life of the two-neutrino double-beta decay of this
nucleus. We show in this work that randomly coinciding events of the
two-neutrino double decay of Mo in enriched LiMoO
detectors can be effectively discriminated by pulse-shape analysis in the light
channel if the scintillating bolometer is provided with a Neganov-Luke light
detector, which can improve the signal-to-noise ratio by a large factor,
assumed here at the level of on the basis of preliminary
experimental results obtained with these devices. The achieved pile-up
rejection efficiency results in a very low contribution, of the order of counts/(keVkgy), to the background counting rate
in the region of interest for a large volume ( cm)
LiMoO detector. This background level is very encouraging in
view of a possible use of the LiMoO solution for a bolometric
tonne-scale next-generation experiment as that proposed in the CUPID project
Anémie et parasitoses (intestinales et urinaires) chez les enfants d’âge scolaire au Burkina Faso: cas des écoles de Yamtenga, Daguilma et Koubri
La présente étude vise principalement à évaluer le statut de l’anémie associé à l’état parasitaire chez des enfants de trois écoles riveraines de retenues d’eaux au Burkina Faso: Daguilma, Koubri et Yamtenga. Il s’agit d’une étude transversale réalisée d’avril 2004 à octobre 2014. L’évaluation de l’anémie a été basée sur la mesure du taux d’hémoglobine à l’aide de l’appareil Hemocue. La caractérisation des parasitoses intestinales a été réalisée en utilisant la méthode de formol éther. La méthode de filtration de Plouvier a été utilisée pour identifier les oeufs de schistosomes. Au total, 363 écoliers dont 182 garçons et 181 filles ont participé à l’étude. La prévalence de l’anémie chez les écoliers à Yamtenga, Koubri et Daguilma est respectivement de 35,83%, 28,33% et 41,46%. Aucune différence significative n’a été notée entre filles et garçons au niveau de chaque site et sur l’ensemble des 3 sites (p= 1). La prévalence globale des parasites intestinaux chez les écoliers est de 75,83%. Pour la schistosomiase urinaire, 5,83% des écoliers sont infectés à Yamtenga, 4,33% à Koubri et 3,06% à Daguilma. La différence est significative entre les garçons (11,67%) et les filles (0,0%) à Yamtenga (p= 0,01). Par contre, à Koubri et à Daguilma, aucune différence significative n’a été observée entre les garçons et les filles (p= 0,619 et p= 1, respectivement).Tous les écoliers infectés par les Ankylostomes, Trichocéphales et Ascaris sont anémiés au niveau des trois sites de l’étude. Parmi les 16 écoliers infectés par la schistosomiase urinaire, 11 présentent une anémie. De l’ensemble des résultats de cette étude, il ressort que la prévalence de l’anémie chez les enfants est fortement influencée par les géohelminthes et la schistosomiase urinaire.Mots clés : Anémie, parasite intestinal, schistosome, élève, Burkina Faso
Final results of an experiment to search for 2beta processes in zinc and tungsten with the help of radiopure ZnWO4 crystal scintillators
A search for the double beta decay of zinc and tungsten isotopes has been
performed with the help of radiopure ZnWO4 crystal scintillators (0.1-0.7 kg)
at the Gran Sasso National Laboratories of the INFN. The total exposure of the
low background measurements is 0.529 kg yr. New improved half-life limits on
the double beta decay modes of 64Zn, 70Zn, 180W, and 186W have been established
at the level of 10^{18}-10^{21} yr. In particular, limits on double electron
capture and electron capture with positron emission in 64Zn have been set:
T_{1/2}(2\nu 2K) > 1.1 10^{19} yr, T_{1/2} (0\nu 2\epsilon) > 3.2 10^{20} yr,
T_{1/2} (2\nu \epsilon \beta^+) > 9.4 10^{20} yr, and T_{1/2} (0\nu \epsilon
\beta^+) > 8.5 10^{20} yr, all at 90% C.L. Resonant neutrinoless double
electron capture in 180W has been restricted on the level of T_{1/2} (0\nu
2\epsilon) > 1.3 10^{18} yr. A new half-life limit on alpha transition of 183W
to the metastable excited level 1/2^- 375 keV of 179Hf has been established:
T_{1/2} > 6.7 10^{20} yr.Comment: This is an author-created, un-copyedited version of an article
published in J. Phys. G: Nucl. Part. Phys. IOP Publishing Ltd is not
responsible for any errors or omissions in this version of the manuscript or
any version derived from it. The definitive publisher authenticated version
is available online at doi: 10.1088/0954-3899/38/11/11510
Investigation of rare nuclear decays with BaF crystal scintillator contaminated by radium
The radioactive contamination of a BaF scintillation crystal with mass of
1.714 kg was measured over 101 hours in the low-background DAMA/R&D set-up deep
underground (3600 m w.e.) at the Gran Sasso National Laboratories of INFN
(LNGS, Italy). The half-life of Po (present in the crystal scintillator
due to contamination by radium) was measured as Po) =
298.80.8(stat.)1.4(syst.) ns by analysis of the events' pulse
profiles. The Rn nuclide is known as 100% decaying via emission of
particle with = 3.82 d; however, its decay is also
energetically allowed with keV. Search for decay chains of
events with specific pulse shapes characteristic for or for
signals and with known energies and time differences allowed us
to set, for the first time, the limit on the branching ratio of Rn
relatively to decay as % at 90% C.L. (equivalent to
limit on partial half-life y). Half-life limits of
Pb, Rn and Ra relatively to decays are also
improved in comparison with the earlier results.Comment: 10 pages, 9 figures, 2 table
Search for double beta decay of Ce and Ce with HPGe gamma detector
Search for double decay of Ce and Ce was realized
with 732 g of deeply purified cerium oxide sample measured over 1900 h with the
help of an ultra-low background HPGe detector with a volume of 465
cm at the STELLA facility of the Gran Sasso National Laboratories of the
INFN (Italy). New improved half-life limits on double beta processes in the
cerium isotopes were set at the level of ~yr;
many of them are even two orders of magnitude larger than the best previous
results.Comment: 21 pages, 6 figures, 3 tables; version accepted for publication on
Nucl. Phys.
Search for long-lived superheavy eka-tungsten with radiopure ZnWO crystal scintillator
The data collected with a radioactively pure ZnWO crystal scintillator
(699 g) in low background measurements during 2130 h at the underground (3600 m
w.e.) Laboratori Nazionali del Gran Sasso (INFN, Italy) were used to set a
limit on possible concentration of superheavy eka-W (seaborgium Sg, Z = 106) in
the crystal. Assuming that one of the daughters in a chain of decays of the
initial Sg nucleus decays with emission of high energy particle
( MeV) and analyzing the high energy part of the measured
spectrum, the limit N(Sg)/N(W) < 5.5 10 atoms/atom at
90% C.L. was obtained (for Sg half-life of 10 yr). In addition, a limit on
the concentration of eka-Bi was set by analysing the data collected with a
large BGO scintillation bolometer in an experiment performed by another group
[L. Cardani et al., JINST 7 (2012) P10022]: N(eka-Bi)/N(Bi) < 1.1
10 atoms/atom with 90% C.L. Both the limits are comparable with those
obtained in recent experiments which instead look for spontaneous fission of
superheavy elements or use the accelerator mass spectrometry.Comment: 9 pages, 2 figures; in press on Physica Script
Search for 2\beta\ decays of 96Ru and 104Ru by ultra-low background HPGe gamma spectrometry at LNGS: final results
An experiment to search for double beta decay processes in 96Ru and 104Ru,
which are accompanied by gamma rays, has been realized in the underground Gran
Sasso National Laboratories of the I.N.F.N. (Italy). Ruthenium samples with
masses of about (0.5-0.7) kg were measured with the help of ultra-low
background high purity Ge gamma ray spectrometry. After 2162 h of data taking
the samples were deeply purified to reduce the internal contamination of 40K.
The last part of the data has been accumulated over 5479 h. New improved half
life limits on 2\beta+/\epsilon \beta+/2\epsilon\ processes in 96Ru have been
established on the level of 10^{20} yr, in particular for decays to the ground
state of 96Mo: T1/2(2\nu 2\beta+) > 1.4 10^{20} yr, T1/2(2\nu \epsilon\beta+) >
8.0 10^{19} yr and T1/2(0\nu 2K) > 1.0 10^{21} yr (all limits are at 90% C.L.).
The resonant neutrinoless double electron captures to the 2700.2 keV and 2712.7
keV excited states of 96Mo are restricted as: T1/2(0\nu KL) > 2.0 10^{20} yr
and T1/2(0\nu 2L) > 3.6 10^{20} yr, respectively. Various two neutrino and
neutrinoless 2\beta\ half lives of 96Ru have been estimated in the framework of
the QRPA approach. In addition, the T1/2 limit for 0\nu 2\beta- transitions of
104Ru to the first excited state of 104Pd has been set as > 6.5 10^{20} yr.Comment: 14 pages, 5 figures, 2 tables; version accepted for publication on
Phys. Rev.
Background suppression in massive TeO bolometers with Neganov-Luke amplified light detectors
Bolometric detectors are excellent devices for the investigation of
neutrinoless double-beta decay (0). The observation of such
decay would demonstrate the violation of lepton number, and at the same time it
would necessarily imply that neutrinos have a Majorana character. The
sensitivity of cryogenic detectors based on TeO is strongly limited by the
alpha background in the region of interest for the 0 of
Te. It has been demonstrated that particle discrimination in TeO
bolometers is possible measuring the Cherenkov light produced by particle
interactions. However an event-by-event discrimination with NTD-based light
detectors has to be demonstrated. We will discuss the performance of a
highly-sensitive light detector exploiting the Neganov-Luke effect for signal
amplification. The detector, being operated with NTD-thermistor and coupled to
a 750 g TeO crystal, shows the ability for an event-by-event identification
of electron/gamma and alpha particles. The extremely low detector baseline
noise, RMS 19 eV, demonstrates the possibility to enhance the sensitivity of
TeO-based 0 experiment to an unprecedented level
- …